• Title/Summary/Keyword: Fukushima nuclear power plant accident

Search Result 130, Processing Time 0.027 seconds

Radionuclides in Environmental Samples and Sample Concentration of Land in the Analysis in the Method of Direct (직접법에서 환경시료중 육상시료의 방사성 핵종 및 농도 분석)

  • Jang, Eun-Sung;Kim, Jin-Seop
    • Journal of Environmental Science International
    • /
    • v.24 no.3
    • /
    • pp.275-280
    • /
    • 2015
  • In order to measure the Radionuclides and Concentration, the directly grinded land samples (river soil, pine leaves and mugwort) among the environment samples around the nuclear power plant were filled in a 450 mL Marinelli beaker and weighed to obtain the dry mass ratio of the samples. Then the background and land samples were measured for 80,000 sec. The analysis of the collected land samples showed that most of them contained less radiation nuclide than the detection minimum limit in the 'Ministry of Education, Science and Technology Public Notice No. 2010-32.'In others, the natural radionuclides $^{40}K$ were detected. Of the products of nuclear reaction discharged by a nuclear reaction, $^{134}Cs$ and $^{137}Cs$ are more easily detected, and their discharge sources can be traced using the relative ratio. Although the radioactive concentration in the vicinity of Kori Nuclear Power Plant, which is more than 1,100km away from Fukushima, the Japanese nuclear accident site, continuous monitoring is needed as the radionuclides can still be accumulated in the soil or animals and plants.

Evaluation of dynamic behavior of coagulation-flocculation using hydrous ferric oxide for removal of radioactive nuclides in wastewater

  • Kim, Kwang-Wook;Shon, Woo-Jung;Oh, Maeng-Kyo;Yang, Dasom;Foster, Richard I.;Lee, Keun-Young
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.738-745
    • /
    • 2019
  • Coprecipitation using hydrous ferric oxide (HFO) has been effectively used for the removal of radionuclides from radioactive wastewater. This work studied the dynamic behavior of HFO floc formation during the neutralization of acidic ferric iron in the presence of several radionuclides by using a photometric dispersion analyzer (PDA). Then the coagulation-flocculation system using HFO-anionic poly acrylamide (PAM) composite floc system was evaluated and compared in seawater and distilled water to find the effective condition to remove the target nuclides (Co-60, Mn-54, Sb-125, and Ru-106) present in wastewater generated in the severe accident of nuclear power plant like Fukushima Daiichi case. A ferric iron dosage of 10 ppm for the formation of HFO was suitable in terms of fast formation of HFO flocs without induction time, and maximum total removal yield of radioactivity from the wastewater. The settling time of HFO flocs was reduced by changing them to HFO-PAM composite floc. The optimal dosage of anionic PAM for HFO-anionic PAM floc system was approximately 1-10 ppm. The total removal yield of Mn-54, Co-60, Sb-125, Ru-106 radionuclides by the HFO-anionic PAM coagulation-flocculation system was higher in distilled water than in seawater and was more than 99%.

ROLE OF PASSIVE SAFETY FEATURES IN PREVENTION AND MITIGATION OF SEVERE PLANT CONDITIONS IN INDIAN ADVANCED HEAVY WATER REACTOR

  • Jain, Vikas;Nayak, A.K.;Dhiman, M.;Kulkarni, P.P.;Vijayan, P.K.;Vaze, K.K.
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.625-636
    • /
    • 2013
  • Pressing demands of economic competitiveness, the need for large-scale deployment, minimizing the need of human intervention, and experience from the past events and incidents at operating reactors have guided the evolution and innovations in reactor technologies. Indian innovative reactor 'AHWR' is a pressure-tube type natural circulation based boiling water reactor that is designed to meet such requirements, which essentially reflect the needs of next generation reactors. The reactor employs various passive features to prevent and mitigate accidental conditions, like a slightly negative void reactivity coefficient, passive poison injection to scram the reactor in event of failure of the wired shutdown systems, a large elevated pool of water as a heat sink inside the containment, passive decay heat removal based on natural circulation and passive valves, passive ECC injection, etc. It is designed to meet the fundamental safety requirements of safe shutdown, safe decay heat removal and confinement of activity with no impact in public domain, and hence, no need for emergency planning under all conceivable scenarios. This paper examines the role of the various passive safety systems in prevention and mitigation of severe plant conditions that may arise in event of multiple failures. For the purpose of demonstration of the effectiveness of its passive features, postulated scenarios on the lines of three major severe accidents in the history of nuclear power reactors are considered, namely; the Three Mile Island (TMI), Chernobyl and Fukushima accidents. Severe plant conditions along the lines of these scenarios are postulated to the extent conceivable in the reactor under consideration and analyzed using best estimate system thermal-hydraulics code RELAP5/Mod3.2. It is found that the various passive systems incorporated enable the reactor to tolerate the postulated accident conditions without causing severe plant conditions and core degradation.

Necessity of management for minor earthquake to improve public acceptance of nuclear energy in South Korea

  • Choi, Hyun-Tae;Kim, Tae-Ryong
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.494-503
    • /
    • 2018
  • As public acceptance of nuclear energy in Korea worsens due to the Fukushima accident and the earthquakes that occurred in the Gyeongju area near the Wolsong nuclear power plant (NPP), estimating the effects of earthquakes has become more essential for the nuclear industry. Currently, most countermeasures against earthquakes are limited to large-scale disasters. Minor-scale earthquakes used to be ignored. Even though people do not feel the shaking due to minor earthquakes and minor earthquakes incur little damage to NPPs, they can change the environmental conditions, for instance, underground water level and the conductivity of the groundwater. This study conducted a questionnaire survey of residents living in the vicinity of an NPP to determine their perception and acceptance of plant safety against minor earthquakes. The results show that the residents feel earthquakes at levels that can be felt by people, but incur little damage to NPPs, as minor earthquakes (magnitude of 2.0-3.9) and set this level as a standard for countermeasures. Even if a minor earthquake has little impact on the safety of an NPP, there is still a possibility that public opinion will get worse. This study provides analysis results about problems of earthquake measures of Korean NPPs and specific things that can bring about an effect of deterioration of public acceptance. Based on these data, this article suggests that active management of minor earthquakes is necessary for the sustainability of nuclear energy.

The effect of the number of subintervals upon the quantification of the seismic probabilistic safety assessment of a nuclear power plant

  • Ji Suk Kim;Man Cheol Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1420-1427
    • /
    • 2023
  • Seismic risk has received increased attention since the 2011 Fukushima accident in Japan. The seismic risk of a nuclear power plant is evaluated via seismic probabilistic safety assessment (PSA), for which several methods are available. Recently, the discrete approach has become widely used. This approximates the seismic risk by discretizing the ground motion level interval into a small number of subintervals with the expectation of providing a conservative result. The present study examines the effect of the number of subintervals upon the results of seismic risk quantification. It is demonstrated that a small number of subintervals may lead to either an underestimation or overestimation of the seismic risk depending on the ground motion level. The present paper also provides a method for finding the boundaries between overestimation and underestimation regions, and illustrates the effect of the number of subintervals upon the seismic risk evaluation with an example. By providing a method for determining the effect of a small number of subintervals upon the results of seismic risk quantification, the present study will assist seismic PSA analysts to determine the appropriate number of subintervals and to better understand seismic risk quantification.

Sentiment analysis of nuclear energy-related articles and their comments on a portal site in Rep. of Korea in 2010-2019

  • Jeong, So Yun;Kim, Jae Wook;Kim, Young Seo;Joo, Han Young;Moon, Joo Hyun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.1013-1019
    • /
    • 2021
  • This paper reviewed the temporal changes in the public opinions on nuclear energy in Korea with a big data analysis of nuclear energy-related articles and their comments posted on the portal site NAVER. All articles that included at least one of "nuclear energy," "nuclear power plant (NPP)," "nuclear power phase-out," or "anti-nuclear" in their titles or main text were extracted from those posted on NAVER in January 2010-December 2019. First, we performed annual word frequency analysis to identify what words had appeared most frequently in the articles. For that period, the most frequent words were "NPP," "nuclear energy," and "energy." In addition, "safety" has remained in the upper ranks since the Fukushima NPP accident. Then, we performed sentiment analysis of the pre-processed articles. The sentiment analysis showed that positive-tone articles have been reported more frequently than negativetone over the entire analysis period. Last, we performed sentiment analysis of the comments on the articles to examine the public's intention regarding nuclear issues. The analysis showed that the number of negative comments to articles each month-irrespective of positive or negative tone-was always larger than that of positive comments over the entire analysis period.

Effect of Typhoons on Contaminants Released from the Southern Sea around Fukushima of Japan (일본 후쿠시마 근해에서 방출된 오염물질에 미치는 태풍의 영향)

  • Hong, Chul-Hoon;Kim, Jinpyo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.2
    • /
    • pp.234-240
    • /
    • 2016
  • We examined the diffusion of contaminants released from the southern coast around Fukushima, Japan, during the passage of typhoons using a three-dimensional numerical model (POM) to track diffusing radioactivity (RA) released from the nuclear power plant at Fukushima following the accident caused by the giant tsunami event in March 2011. Radioactive contaminants released during the passage of typhoons may have significantly affected not only Japanese but also Korean coastal waters. The model domain covered most of the northwestern Pacific including marginal seas such as the East/Japan Sea and the Yellow Sea. Several numerical experiments were conducted case studies focusing on the westward diffusion from the southern coast of Japan of contaminants derived from the source site (Fukushima) according to various attributes of the typhoons, such as intensity, track, etc. The model produced the following results 1) significant amounts of contaminants were transported in a westward direction by easterly winds favorable for generating a coastal air stream along the southern Japanese coast, 2) the contaminants reached as far as Osaka Bay with the passage of typhoons, forced by a 5-day positive sinusoidal form with a (right-) northward track east of Fukushima, and 3) the range of contamination was significant, extending to the interior of the East/Japan Sea around the Tsugaru Strait. The model suggests that contaminants and/or radioactivity released from Fukushima with the passage of typhoons can affect Korean waters including the northeastern East/Japan Sea around the Tsugaru Strait, especially when the typhoon tracks are favorable for generating a westward coastal air stream along the southern Japanese coast.

Repair and Replacement Methodology for Electrical Equipment Used in Nuclear Power Plants (원자력발전소 전기기기의 보수, 교체 방법론)

  • Park, Chulhee;Park, Wan-gyu;Lee, Manbok;Kim, Choon-sam
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.177-179
    • /
    • 2018
  • After Fukushima nuclear accident at 2011, nuclear industrial has been focused on operation and maintenance phase, not design and construction phase. Continued good operating performance of nuclear power plants has been the best critical issue to nuclear utilities. Replacement for complete components as well as parts of components is being procured because nuclear utilities must maintain safety and reliability of operating nuclear power plants. However, many suppliers and manufacturers are giving up a nuclear quality assurance program under reduction in new construction of nuclear power plants. It is able to be increased difficulty in procuring spare parts to support operations and maintenance of nuclear power plants. Over 20% of nuclear power plant equipment in some countries is obsolete. Owing to obsolescence of nuclear safety-related items and/or withdrawing a nuclear quality assurance program of suppliers and manufactures, some replacement item and part might be procured to the item not covered by appendix B to USNRC 10 CFR Part 50. Under various methods of the nuclear repair and replacement methodology, utilities are supposed to establish a typical program for a repair and replacement of an electrical equipment and its parts in conjunction with a nuclear quality assurance. Concerning this typical program, this study suggests the repair and replacement methodology of electrical equipments used in nuclear power plants by procurement of a power supply, based on nuclear regulations, codes, standards, guidelines, specific and general technical information, etc..

  • PDF

Looking Back over a Decade "Final Decision Call after the Accidents of the Fukushima Nuclear Power Plant"

  • Nakajima, Isao;Kurokawa, Kiyoshi
    • Journal of Multimedia Information System
    • /
    • v.7 no.2
    • /
    • pp.147-156
    • /
    • 2020
  • The author Nakajima was involved in the field of disaster communications and emergency medical care as guest research scientist at the Fukushima Nuclear Accident Independent Investigation Commission established by the National Diet of Japan and reviewer of the Commission's report, and Kurokawa was the chairman of this Commission. Looking back over a decade, we are on the liability issue of bureaucrats and telecom operators, so it's becoming clear what was hidden at the time. The battery of NTT DoCoMo's mobile phone repeaters had a capacity of only about 24 hours, and communication failures increased after one day. The Government also failed to issue an announcement of "Vent from reactor" under the Telecommunications Act Article No. 129. This mistake lost the opportunity to use the third-party telecommunications (e.g. taxi radios). Furthermore, as a result of LASCOM (telecommunications satellite network for local governments via GEO) and a variety of unexpected communication failures, the evacuation order "Escape!" could not be notified to the general public well. As a result, the general public was exposed to unnecessary radiation exposure. Such bureaucratic slow action in emergencies is common in the response to the 2020 coronavirus.

Kindergarten parents' perceptions on radioactive-contaminated foods and irradiated foods - Focus on the accident of unclear plant in Japan, 2011 - (방사능 오염식품과 방사선조사 식품에 관한 유치원 부모의 인식 - 2011년 일본 원전사고의 영향력을 중심으로 -)

  • Yang, Jinhee;Park, Yun;Yeo, Hwayeon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.435-440
    • /
    • 2012
  • The purpose of this study was to examine the impact of the Fukushima nuclear power plant accident of Japan in 2011 on kindergarten parents' perception about irradiated foods and radioactive-contaminated foods. This study analysed the 178 questionnaire forms out of 205 parents of 'K' and 'M' kindergarten in the region of 'J' city. The findings of the study indicated that the Japanese nuclear power plant accident exerted an influence on anxious of kindergarten parents about irradiated foods and radioactive-contaminated foods. In conclusion, The full-fledged publicity and parent education are required to improve the perception and understanding of kindergarten parents about irradiated foods and the differences between it and radioactive-contaminated foods.