• Title/Summary/Keyword: Frost Layer

Search Result 99, Processing Time 0.023 seconds

Computing Procedure of Daily Average Air Temperature using Field Data and Frost Index Calibration for Anti-Frost Heave Layer Design (현장계측 데이터를 이용한 일평균 대기온도 산정방법과 동상방지층 설계를 위한 동결지수 보정)

  • Cho, Myung-Hwan;Kim, Nakseok;Shim, Jaepill
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3D
    • /
    • pp.433-439
    • /
    • 2011
  • The frost depth(frost penetration) is used to install anti-frost heave layers in pavement designs. The freezing index is calculated by an annual accumulated value of multiplying the period of time with temperatures below zero, and the corresponding temperature. Therefore, the DAAT(daily average air temperature) calculation method may play an effect on the FI(freezing index). The Weather Observatory used to supply 4 average air temperatures per day, but currently supplies 8 per day. With this study, we divided the southern part(below FI=$350^{\circ}C{\cdot}day$) of the Korean peninsula into 6 areas according to site conditions(low embankment, embankment-cutting slope, and the cutting slope) and established a field measurement system for 15 positions to check the effects on the result of FI according to differing DAAT calculation methods. The air temperatures obtained by the field measurement system was used to calculate and compare the FI. As a result, the freezing index calculated based on the $DAAT_4(T_4)$ is normally greater by 3% than the one on $DAAT_8(T_8)$. In addition, the calibration equation for the freezing index using air temperatures was proposed through the research.

An Experimental Study on Frost Generation Mechanism from Evaporator Tube in Air Conditioning System (공조용 열교환기 증발관에서의 서리 발생에 관한 메커니즘의 실험적 연구)

  • Park Sang-Kyun;Oh Cheal
    • Journal of Navigation and Port Research
    • /
    • v.30 no.1 s.107
    • /
    • pp.113-117
    • /
    • 2006
  • The object qf this experiment was the evaluation of the growth rate of frost layer conditioned by inlet air's velocity, temperature and relative humidity on the copper tube in evaporator. In this experiment, the inlet air's velocity were $0.3^m/_s,\;0.6^m/_s,\;0.9^m/_s,$ temperature were $15^{\circ}C,\;20^{\circ}C,\;25^{\circ}C$ and the variation of relative humidity was $70\%~90\%$. And the brine temperature flowing through the copper tubes was kept $-15{\circ}C$ because generally cooling temperature range is constantly $-15^{\circ}C$ in the heat exchanger for air conditioning system It was found that the amount of frost generation increased so that the relative humidity, velocity and temperature of supply air increased.

A Dynamic Characteristic of the Multi-Inverter Heat Pump with Frosting (착상을 수반한 멀티 가변속 열펌프의 동특성)

  • ;;Shigeru Koyama
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.337-345
    • /
    • 2003
  • In the case of heat exchangers operating under frosting condition, the growth of frost layer causes the heat exchanger to increase the thermal resistance and pressure loss of the air flow. In this paper, a transient characteristic prediction model of the heat transfer for multi inverter heat pump with frosting on its surface was presented taking into account the change of the fin efficiency due to the growth of the frost layer. In this dynamic simulation program, which was peformed for a basic air conditioning system model, such as evaporator, condenser, compressor, linear electronic expansion valve (LEV) and bypass circuit. The theoretical model was driven from the obtained heat transfer coefficient and mass transfer coefficient, independently. And we consider heat transfer performance was only affected by a decrease of the wind flow area. The calculated results were compared with some cases of experiments for frosting conditions.

Development of the Dynamic Simulation Program of a Multi-Inverter Heat Pump under Frosting Conditions

  • Park Byung-Duck;Lee Joo-Dong;Chung Baik-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.3
    • /
    • pp.113-122
    • /
    • 2004
  • In case of heat exchangers operating under frosting condition, the thermal resistance and the air-side pressure loss increase with a growth of frost layer. In this paper, a transient characteristic prediction model of the heat transfer for a multi-inverter heat pump with frosting on its surface was presented by taking into account the change of the fin efficiency due to the growth of the frost layer. This dynamic simulation program was developed for a basic air conditioning system composed of an evaporator, a condenser, a compressor, a linear electronic expansion valve, and a bypass circuit. The theoretical model was derived from measured heat transfer and mass transfer coefficients. We also considered that the heat transfer performance was only affected by the decrease of wind flow area. The calculated results were compared with the experimental results for frosting conditions.

Characteristics of the Lower Boundary Layer during Frost Nights (찬공기 호수지형에서 서리발생시 하층대기 특성 - 경상남도 하동을 중심으로)

  • 황규홍;이정택;허승오;심교문
    • Proceedings of The Korean Society of Agricultural and Forest Meteorology Conference
    • /
    • 2001.06a
    • /
    • pp.65-67
    • /
    • 2001
  • 경계층(boundary layer)은 대류권(troposhpere)의 일부분으로써 지구 표면에 직접적인 영향을 주고, 두께는 지표에서 100∼3000m이다. 고기압의 영향을 받는 지역에서 수직 경계층은 일출후부터 일몰 전까지인 낮 시간에 난류 혼합층(turbulent mixed layer), 낮 시간에 형성된 혼합층이 야간에 잔류하는 층, 야간 안정 경계층(Stable Boundary Layer:SBL)으로 나눌 수 있다(Stull, 1988).(중략)

  • PDF

Frost Prevention of Fin-Tube Heat Exchanger by Spreading Antifreezing Solution (부동액 도포에 의한 핀-튜브 열교환기 착상방지)

  • Oh, Sang-Youp;Chang, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.477-485
    • /
    • 2006
  • A study on frost prevention of fin-tube heat exchanger is experimently performed by spreading antifreezing solution on heat exchanger surface. It is desirable that the antifreezing solution spreads completely on the surface forming thin liquid film to prevent frost nucleation and crystal growth and to reduce the thermal resistance across the liquid film. A small amount of antifreezing solution falls in drops on heat exchanger surface using two types of supplying devices, and a porous layer coating technique is adopted to enhance the wettedness of antifreezing solution on the surface. It is observed that the antifreezing solution liquid film prevents fin-tube heat exchanger from frosting, and heat transfer performance does not degrade through the frosting tests. The concentration of supplied antifreezing solution can be determined by heat transfer analysis of the first row of heat exchanger to avoid antifreezing solution freezing due to dilution by moisture absorption.

Comparison of Modified Berggren Method with Numerical Method for the Frost Penetration Depth (수정 Berggren 법과 수치해석법에 의한 동결깊이 산정 비교)

  • Kim, Kwangjin;Kim, Youngchin;Lee, Daeyoung;Lee, Hayoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.6
    • /
    • pp.21-29
    • /
    • 2013
  • This paper presents computed frost penetration depths for a number of cross sections of multilayered system including insulation. Results of Modified Berggren method were compared with those of numerical analysis which is based on finite element method with phase change. For the homogeneous single layer medium, Modified Berggren method gives almost the same results as finite element based numerical method. For the multilayered systems with insulation, Modified Berggren method shows, however, inaccurate results compared with FEM results. Therefore numerical solution based on finite element or finite difference should be used in place of Modified Beggren method to estimate the frost penetration depth for the layered medium with insulation.

Verification of Freezing Index and Frost Penetration Depth with Temperature Data of Korea LTPP (국내 LTPP 온도 자료를 이용한 동결지수와 동결깊이 검증 연구)

  • Kim, Boo-Il;Jeon, Sung-Il;Lee, Moon-Sup;Lim, Kwang-Su
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.143-152
    • /
    • 2009
  • The purpose of this study is to evaluate the freezing index and frost penetration depth. The freezing index and frost penetration depth were analyzed using air temperature and temperature profile of pavement system in Korea LTPP-SPS(Long Term Pavement Performance-Specific Pavement Study) site. The predicted frost penetration depth were then compared with the measured one from the LTPP sites. And the trend of annual freezing index was analyzed using the temperature data of meteorological stations located in the vicinity of Korea LTPP-SPS site. The result showed that the freezing index was rapidly decreased since 1987, and it was known that the use of freezing index determined from the past 30 years temperature data could cause the over estimates in the pavement thickness design. The temperature profile measured at 3 sections of LTPP-SPS sites showed that the temperature of subbase layer was above $0^{\circ}C$, even though anti-frost layers were found in these sections. Comparing the measured and calculated frost depth, the frost depth calculated from the subgrade frost penetration permissible method showed a similar trend with the measured frost depth.