• Title/Summary/Keyword: Front Side-wall

Search Result 66, Processing Time 0.034 seconds

The Spatial Organization of Gyeongbok Palace and The Six Ministries A venue in the Early Joseon Dynasty - The Ceremony at the Main Gate and its Meaning - (조선초기 경복궁의 공간구조성과 6조대로 - 광화문 앞의 행사와 그 의미 -)

  • Kim, Dong-Uk
    • Journal of architectural history
    • /
    • v.17 no.4
    • /
    • pp.25-42
    • /
    • 2008
  • The Gyeongbok Palace was completed during the reign of King Taejo and King Sejong in the early Joseon Dynasty. The most remarkable spacious feature of the palace is that it has an inner palace wall without an outer palace wall. The absence of the outer palace wall had its origin in the palace of the late Goryeo Dynasty which did not provide the outer palace wall. Gwanghwamoon was the main gate of the palace, and the office buildings of the Six Ministries were arranged on the right side in front of the main gate. A wide road called Six Ministries Avenue was made between the builidings. The avenue was completed during the reign of the third king of Joseon, Taejong, and it was assumed that this arrangement was influenced by the government office arrangements of Nanjing, the early capital city of the Ming Dynasty. Gwanghwamoon held national rituals as well as the civic and military state examinations nations in front of the gate. The avenue was decorated with flowers and silks when kings and the royal families, or Chinese envoys enter the gate, and the civilians watched the parade, Because there was no outer palace wall, all the events held at Gwanghwamoon and the Six Ministries Avenue ware opened to the public, it was the unique feature of Gyeongbok Palace that the palaces of Goryeo dynasty and China did not have.

  • PDF

A Study on the Flow Characteristics around Intakes within a Sump by PIV (PIV에 의한 흡입수조내 흡입관 주위의 유동특성에 관한 연구)

  • Choi, J. W.;Kim, J. H.;Kim, K. Y.;Kim, Y. T.;Lee, Y. H.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.3 s.16
    • /
    • pp.33-39
    • /
    • 2002
  • The head-capacity corves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and with no stray currents. Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. However, various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall, and back-wall due to different clearances from back-wall to vortical intake pipe. Moreover, the locations and patterns of the various types of vortices that were found in the examinations are discussed.

A PIV Measurement on Flow Characteristics of Intakes within a Sump in a Pump Station (펌프장의 흡입수조내 흡입관의 유동특성에 관한 PIV 측정)

  • Lee, Yeong-Ho;Kim, Yu-Taek;Kim, Jeong-Hwan;Choe, Jong-Ung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.209-215
    • /
    • 2001
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and no stray currents, Hence, flow into the Pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. But various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall and back-wall due to different clearances from back-wall to vertical in take pipe. Moreover, the locations and vorticities of the various types of vortices that were found in the examinations are discussed.

  • PDF

An Analytical Model for Deriving the 3-D Potentials and the Front and Back Gate Threshold Voltages of a Mesa-Isolated Small Geometry Fully Depleted SOI MOSFET

  • Lee, Jae Bin;Suh, Chung Ha
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.4
    • /
    • pp.473-481
    • /
    • 2012
  • For a mesa-isolated small geometry SOI MOSFET, the potentials in the silicon film, front, back, and side-wall oxide layers can be derived three-dimensionally. Using Taylor's series expansions of the trigonometric functions, the derived potentials are written in terms of the natural length that can be determined by using the derived formula. From the derived 3-D potentials, the minimum values of the front and the back surface potentials are derived and used to obtain the closed-form expressions for the front and back gate threshold voltages as functions of various device parameters and applied bias voltages. Obtained results can be found to explain the drain-induced threshold voltage roll-off and the narrow width effect of a fully depleted small geometry SOI MOSFET in a unified manner.

DIRECT NUMERICAL SIMULATION OF IMMISCIBLE GAS BUBBLE DISPLACEMENT IN 2D CHANNEL (2차원 관내 유동에서 불활성 기체 제거과정의 직접 수치 해석)

  • Shin, S.
    • Journal of computational fluids engineering
    • /
    • v.12 no.3
    • /
    • pp.41-46
    • /
    • 2007
  • Dynamic behavior of immiscible gas bubble attached to the wall in channel flow plays very important role in many engineering applications. Special attention has been paid to micro direct methanol fuel cell(${\mu}$DMFC) where surface tension becomes dominant factor with minor gravitational effect due to its reduced size. Therefore, displacement of $CO_2$ bubble generating on a cathode side in ${\mu}$DMFC can be very difficult and efficient removal of $CO_2$ bubbles will affect the overall machine performance considerably. We have focused our efforts on studying the dynamic behavior of immiscible bubble attached to the one side of the wall on 2D rectangular channel subject to external shear flow. We used Level Contour Reconstruction Method(LCRM) which is the simplified version of front tracking method to track the bubble interface motion. Effects of Reynolds number, Weber number, advancing/receding contact angle and property ratio on bubble detachment characteristic has been numerically identified.

Study on Angular Momentum Transfer in Polymer Solutions (폴리머 용액에서의 각운동량 전달에 관한 연구)

  • Kim, Jae-Won;Ahn, Eun-Young;Oh, Jung-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.1 s.244
    • /
    • pp.67-73
    • /
    • 2006
  • This investigation deals with the spin-up flows in a circular container of aspect ratio, 2.0. Shear front is generated in the transient spin-up process and propagating from the side wall to the central axis in a rotating container. Propagation of the shear front to the axis in a rotating container means the region acquires an angular momentum transfer from the solid walls. Propagating speed of the shear front depends on the apparent viscosity of polymer solution. Two kinds of polymer solutions are considered as a working fluid: one is CMC and the other is CTAB solution. CMC solution has larger apparent viscosity than that of water, and CTAB shows varying apparent viscosities depending on the applied shear rates. Transient and spatial variations of the apparent viscosities of the present polymer solutions (CTAB and CMC) cause different speeds of the propagating shear front. In practice, CMC solution that has larger values of apparent viscosity than that of water always shows rapid approach to the steady state in comparison of the behavior of the flows with water. However, for the CTAB solution, the speed of the propagating of the shear front changes with the local magnitude of its apparent viscosity. Consequently, the prediction of Wedemeyer's model quantitatively agrees with the present experimental results.

A Study on the Spatial Elements of Flexible Apartments - Focusing on Local and Foreign Flexible Apartments - (가변형 공동주택의 공간 요소 특성 연구 - 국내외 가변형 공동주택을 중심으로 -)

  • Cho, Il-A;Park, Kyung-Hwan;Kim, Hyung-Woo
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.3 s.62
    • /
    • pp.66-75
    • /
    • 2007
  • In this study, by comparing the development and the space types of local and foreign flexible apartments, basic data will be derived for the development of various flexible types of apartments in Korea. A total of 60 unit plans, including 30 domestic cases and 30 overseas cases of flexible apartments, are analyzed for this study. In terms of the unit plan types, Korean apartments usually had a wide front bay with shallow depth, placing more rooms on the front bay; whereas foreign apartments tend to have various unit plan types: (1) a narrow front bay with deep depth, (2) a wide front bay with shallow depth, and (3) variegated open-plan types. Many apartments in foreign countries had a double-layered structure with the. upstairs and downstairs areas. In terms of the flexible types, many Korean apartments achieved interior flexibility using non-bearing wall or sliding doors; whereas foreign apartments had a flexible space by separating the support elements and the infill elements. There was found to be a close relationship between the location of support elements and the variability of unit plans. Support elements can be placed largely into three locations: (1) Between the front side bay and the rear side bay, (2) in the center bay of a unit plan, and (3) others. Depending on the location of support elements, various types of flexible unit plans can be created. Through a comparative analysis of domestic and foreign apartments, basic data that can be used for developing various flexible unit plans was derived.

A Study on the Behavior of the Free Space Scatter dose in X-ray Diagnostic Room (X선촬영실 내에서의 공간산란선량 변동에 관한 연구)

  • Oh, Hyun-Joo;Kim, Sung-Soo;Kim, Young-Il;Lim, Han-Young;Kim, Heung-Tae;Lee, Who-Min;Kim, Hak-Sung;Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.17 no.2
    • /
    • pp.21-27
    • /
    • 1994
  • In this pauper, when the X-ray exposure condition is 70, 90, 110 kV, 10 mAs, FFD 180 cm, FSO $10{\times}10$, $35{\times}35\;cm$, toward the $36{\times}36{\times}15\;cm$ acryl phantom, the free space scatter dose rate at the 15th points in X-ray diagnostic room was measured by electrometer and 1800 co ionization chamber. Therefore, the free space scatter dose distribution profile was drown, and then, the free space scatter dose contribution percentage was Investigated. The obtained results are summarized as following. 1. The X-ray tube leakage dose rate of the experiment generator at the 1 m from focus was measured maximum 85 mR/hr, minimum 20 mR/hr, therefore, this values was appeared below the KS rules, 2. The free space scatter dose become to larger at the primary X-ray beam around area, and lower at the back ward X-ray tube. The maximum values were 3,812 mR/hr at the front Lt 1 m $45^{\circ}$ point, minimum 117 mR/hr at the back ward 1 m $180^{\circ}C$ point. 3. As the more tube voltage and field size increase, the more free space scatter dose contribution percentage become to increase, as to 90 kV from 70 kV, increase to 12 %, to 110 kV from 90 kV, increase to 18 %, and then, become to 11 % at the $10{\times}10\;cm$ and 87 % at the $35{\times}35\;cm$. 4. The 89 % of the total producted scatter ray occured from acryl phantom, at the X-ray tube housing 6 %, at the front side back wall 5 %. 5. The free space scatter dose contribution percentage at the one point build up 80 % from the phanton direction, 14 % from the X-ray tube and collimator direction, 2.2 % from the front wall, 1.8 % from the side wall, 1.7 % the back wall.

  • PDF

Two dimensional flow and heat/mass transfer characteristics in rectangular wavy duct with corrugation angle (2차 유동 영역에서 꺽임각 변화에 따른 주름진 사각 덕트에서의 열/물질전달 및 유동 특성)

  • Kwon, Hyun-Goo;Hwang, Sang-Dong;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2267-2272
    • /
    • 2007
  • The present study investigates the two dimensional flow and heat/mass transfer characteristics of wavy duct with various corrugation angles. For the heat/mass transfer coefficients, a naphthalene sublimation technique is used. Numerical analysis and wall pressure measurement show detailed two dimensional flow features. The corrugation angles change from 145$^{\circ}$ to 100$^{\circ}$. The operating Reynolds numbers based on the duct hydraulic diameter vary from 700 to 3,000. The duct aspect ratio maintains 7.3. On the pressure wall, strong flow mixing enhances heat/mass transfer coefficients at the front position. In addition, the rear side of pressure wall, the near of peak, is affected by the acceleration and the shedding of main flow. On the suction wall, however, flow separation and reattachment lead to the valley and the peak of heat/mass transfer coefficient. Also, highly increasing boundary layer at the suction wall affects the decrease of heat/masst transfer. As decreasing corrugation angles, the spanwise average Sherwood number increases and the peak or the valley positions of the local Sherwood number are varied.

  • PDF

Drag Reduction by Fence of a Square Prism near Plane Wall (벽면근처에 놓인 정방형주의 펜스에 의한 항력저감)

  • Ro, Ki-Deok;Kim, Kwang-Seok
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2567-2572
    • /
    • 2007
  • The suppression of fluid force acting on a square prism near plane wall was studied by attaching fences on the corners of the prism. The height of the fence was 10% of the square width and the range of Reynolds number considered was Re=$2.0{\times}10^4$. The experimental parameters were the attaching position and numbers of fences, the space ratios G/B(G/B=0.1${\sim}$1.2) between prism and plane wall. The average drag coefficients were increased and the average lift coefficients were decreased and increased with the space ratios toward plane wall. The drag of the prism was reduced average 7.6% with the space ratios by attaching the normal fence at the rear and upper corner and the horizontal normal fence at the rear and lower corner on the prism. In this case, the separated flow at the front and upper corner was reattached on the upper side of the prism and the vortex streets between the prism and plane wall were appeared more slowly than that of prism without fences.

  • PDF