• Title/Summary/Keyword: Fresh air requirements

Search Result 13, Processing Time 0.022 seconds

A Study of Ventilation Requirements for Tunnel Considering Recirculation near Tunnel Portals (인접 터널로부터의 재유입을 고려한 터널 내 소요환기량 산정 연구)

  • Rie, Dong-Ho;Choi, Baek-Yeol;Yoon, Sung-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.66-70
    • /
    • 2010
  • This paper analyzes difference between current tunnel ventilation calculation method and advanced one which considers effects of polluted air recirculation near tunnel portals. For the calculation, CFD(Computational fluid dynamics) technique was utilized. From the result, it was found that 4.38% more fresh air is required when there is polluted air recirculation near tunnel portal areas. Hence, it is recommanded that the consideration of polluted air recirculation should be made when deciding the ventilation requirements for tunnel.

Simulation and Analysis of Local Ventilation characteristic of Road Tunnel with Ventilation System (환기시스템 적용 도로터널의 국소환기 특성 시뮬레이션 및 해석)

  • 박기림;오명도;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.321-332
    • /
    • 2001
  • In this study, a design program for ventilation requirements of a longitudinal raod tunnel were developed and investigated. The control volume method was applied to calculate the local air velocity and the local concentration distribution of pollutants, CO, $NO_x$, soot along the tunnel for various tunnel ventilation system. This program was validated by comparing with the practical design data for the road tunnel ventilation system. The calculation results were in good agreement with the practical design data.

  • PDF

A Design and Application of the Ventilating and Heating System of T-103 Trainer Aircraft for Improvement (T-103 훈련기의 환기와 난방 시스템 개선에 관한 연구)

  • Jung, Daehan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.277-284
    • /
    • 2013
  • In this paper, the ventilating and heating system of T-103 trainer aircraft were investigated and redesigned to improve its poor performance. The ventilation system of the trainer was designed to increase the mass flow rate of fresh air by using air intake valves. The flow-in air through the air intake valve is supplied to the cabin by the ram effect of aircraft and the propeller. And the additional heating system was installed to improve the temperature of the cabin inside. The wasted heat from the exhaust gas of the engines was used as heat source of the additional heating system by installing an heat exchanger around the exhaust nozzle. The additional fresh air and the heated air enter the cabin via two ducts mounted under the instrument panel and behind the pedal in the cabin. The additional ventilating and heating system can be controlled by the first pilot and the secondary pilot individually using the control knob equipped separately. After mounting the additional ventilating and heating system, evaluations such as inspection of parts and component, ground run-up test, in-flight test, user test, etc. were conducted. The result of the tests was sufficient to meet the requirements of the manuals, and the pilots were satisfied with the additionally mounted systems.

A study on characteristics of melting in a air-PCM heat exchanger (상변화 열교환기의 용융특성 연구)

  • Oh, Chang-Mook;Yoo, Young-June
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.127-129
    • /
    • 2011
  • In the building, controlling temperature is main concern for maintaining fresh environment. To control temperature, phase change material(PCM) can be used as a medium that keeps temperature in certain level. PCM has its own phase change temperature. PCM melts/solidifies while absorbing/releasing the heat. Because of the advantage, PCM can be applied to a air-PCM heat exchanger. In this study, the air-PCM heat exchanger was designed based on the system requirements and experimental analysis was conducted to study on the performance of the heat exchanger.

  • PDF

Development of a Flow-duct for Uniform Flow of Chilly Air in a Refrigerator (냉장고의 균일 냉기유동을 위한 유동구조 개선에 관한 연구)

  • Yu, Jae-Hyun;Kim, Pan-Gun;Park, Sang-Hu;Bae, Won-Byong;Kim, Ju-Wan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.9
    • /
    • pp.995-1002
    • /
    • 2012
  • In a refrigerator, many food boxes are stored, so the flow of chilly air has very complicate stream paths inside the room of a refrigerator. Moreover, on some occasions, there is no flow of chilly air in a space due to blocking flow paths by food boxes, which is an important issue to be settled for improving the ability of food storage with fresh states. One of methods to solve this problem is to redesign the flow-pattern of chilly air to be uniform flow inside room, if possible. In this work, we have tried to design the duct-structure for the uniform flow of a chilly air using a FE-analysis method. And we conducted real commercial tests using a refrigerator having the redesigned duct. The results showed that good agreements with general requirements.

Germination of West African Ebony (Diospyros mespiliformis Hochst) Seeds: Effects of Dehydration and Different Pre-sowing Treatments

  • Kanmegne, Gabriel;Mbakop, Christelle Nya;Fonkou, Theophile
    • Journal of Forest and Environmental Science
    • /
    • v.36 no.4
    • /
    • pp.267-273
    • /
    • 2020
  • Diospyros mespiliformis is a highly valued and threatened tree species within the Sahelo-Sudanian zone of Africa, but its seed germination requirements under cultivation are not well researched. In a first experiment which aimed at determining germination response of seeds to dehydration, fresh seeds were dried at room temperature for 26 days during which their moisture content, their germinability, and their viability were monitored at two-day intervals. In the second experiment, 14 pre-germination treatments were tested for their effect on the germination of dried seeds. Results showed that fresh seeds had 52.7% moisture and achieved 97.7% germination. As seeds were dried, percentage germination gradually decreased with decreasing moisture content and reached 0% when moisture content had dropped to 18%. Meanwhile, seed viability remained at 100% over drying duration. Seeds that were not germinated after air dry also recorded 100% viability. The most effective treatment for inducing germination of dried seeds was scarification using 98% sulfuric acid for 30 min which resulted in 96.6% germination. This study reports for the first time in D. mespiliformis seeds a desiccation-induced dormancy which can be efficiently alleviated by acid scarification. This study provides useful information that will contribute to efficient management of D. mespiliformis seed resources for propagation.

Elaboration and characterization of fiber-reinforced self-consolidating repair mortar containing natural perlite powder

  • Benyahia, A.;Ghrici, M.;Mansour, M. Said;Omran, A.
    • Advances in concrete construction
    • /
    • v.5 no.1
    • /
    • pp.1-15
    • /
    • 2017
  • This research project aimed at evaluating experimentally the effect of natural perlite powder as an alternative supplementary cementing material (SCM) on the performance of fiber reinforced self-consolidating repair mortars (FR-SCRMs). For this purpose, four FR-SCRMs mixes incorporating 0%, 10%, 20%, and 30% of natural perlite powder as cement replacements were prepared. The evaluation was based on fresh (slump flow, flow time, and unit weight), hardened (air-dry unit weight, compressive and flexural strengths, dynamic modulus of elasticity), and durability (water absorption test) performances. The results reveal that structural repair mortars confronting the performance requirements of class R4 materials (European Standard EN 1504-3) could be designed using 10%, 20%, and 30% of perlite powder as cement substitutions. Bonding results between repair mortars containing perlite powder and old concrete substrate investigated by the slant shear test showed good interlocking justifying the effectiveness of these produced mortars.

Study on Cooling Characteristics of the Tunnel Type Pressure Pre-Cooling System

  • Lee W. O.;Yun H. S.;Lee K. W.;Jeong H.;Cho K. H.;Cho Y. K.;Lee J. H.
    • Agricultural and Biosystems Engineering
    • /
    • v.4 no.2
    • /
    • pp.58-65
    • /
    • 2003
  • An understanding of the cooling requirements of horticultural commodities begins with adequate knowledge of their biological responses. All fresh horticultural products are living organisms, carrying on the many biological processes that are essential to the maintenance of life. The pre-cooling is essential technique for the construction of cold chain system, which is necessary to maintain marketing quality of fresh produces during the transportation and distribution. The purpose of this study is to develop the pressure cooling tunnel using conveyer for the reduction of labor and improvement of pre-cooling efficiency. Performance of developed facility was tested for the strawberries, tomatoes and Chinese cabbages. Cooling ratio as a result of pre-cooling efficiency was 1.57, 1.56 and 1.32 for strawberries, tomatoes, and Chinese cabbages respectively. Cooling ratio decreased with increasing the distance of heat conduction from surface to center. The cooling ratio of Chinese cabbages was lower than that of fruit because of its head and leaf. In aspect of cooling uniformity, there was no significant difference of final temperature among inlet, outlet and middle layers of cold air in fresh produces. After pre-cooling treatment, quality changes were measured for the weight loss, Vit. C content, and titratable acidity. The quality of pre-cooling treatment was better than that of non-treatment and was kept on well during long-term storage.

  • PDF

Mock-up Test of Concrete Using AE Water Reducing Agent of Early-Strength Type in Construction Field (조기강도발현형 AE감수제를 사용한 콘크리트의 현장 Mock-up 실험)

  • 황인성;김기훈;김규동;이승훈;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.1-4
    • /
    • 2004
  • In this paper. applicability of high early strength type AE water reducing agent(HESAEWA) developed by the authors is discussed by applying Mock-up test. For fresh concrete properties, concrete using existing AE water reducing agent(EAEWRA) and HESAEW A meets the target slump and air content at jobsite. Setting time of concrete using HESAEWA is shorter than that using EAEWRA. Remarkable variance of bleeding and settlement is not observed with type of AE water reducing agent. For hardened concrete properties, use of HESAEW A results in higher strength development compared with that of EAEWRA at standard curing and in field curing condition. Reaching time to accomplish 5MPa of compressive strength. which is possible to remove side form. is taken using HESAEWA earlier than that of EAEWRA by 1day. Therefore, it is confirmed that use of HESAEWA can meet the requirements of general quality of concrete and achieve high early strength development as well as has a desirable field applicability.

  • PDF

Proposals for Revision of Lightweight Aggregate Concrete Specifications Based on In-situ Quality Control on Concrete (현장 품질관리를 고려한 경량골재 콘크리트의 시방서 개정안에 대한 고찰)

  • Lee, Kyung-Ho;Yang, Keun-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.3
    • /
    • pp.211-218
    • /
    • 2018
  • This study examined the reliability and revision necessity of concrete standard specifications based on the comparisons with test data obtained by using domestic artificial lightweight aggregates and the contents specified in different foreign specifications including ACI 211.2, ACI 213, ACI 301, JASS 5 and CEB-FIP. To achieve the continuous particle distribution of domestic fine lightweight aggregates, the partial addition of natural sand with the maximum size of 2.5mm was required. To control the segregation and excessive bleeding in the fresh lightweight concrete, the current limitations on the water-to-binder ratio and unit water content need to be modified using lower values. In particular, a rational mixture proportion approach of lightweight concrete needs to be established for the targeted requirements of initial slump, 28-day compressive strength, air content and dry unit weight. Ultimately, significant revision of the concrete standard specifications is required considering the characteristics of domestic artificial lightweight aggregates.