• Title/Summary/Keyword: Frequency tuning

Search Result 693, Processing Time 0.029 seconds

Guided wave field calculation in anisotropic layered structures using normal mode expansion method

  • Li, Lingfang;Mei, Hanfei;Haider, Mohammad Faisal;Rizos, Dimitris;Xia, Yong;Giurgiutiu, Victor
    • Smart Structures and Systems
    • /
    • v.26 no.2
    • /
    • pp.157-174
    • /
    • 2020
  • The guided wave technique is commonly used in structural health monitoring as the guided waves can propagate far in the structures without much energy loss. The guided waves are conventionally generated by the surface-mounted piezoelectric wafer active sensor (PWAS). However, there is still lack of understanding of the wave propagation in layered structures, especially in structures made of anisotropic materials such as carbon fiber reinforced polymer (CFRP) composites. In this paper, the Rayleigh-Lamb wave strain tuning curves in a PWAS-mounted unidirectional CFRP plate are analytically derived using the normal mode expansion (NME) method. The excitation frequency spectrum is then multiplied by the tuning curves to calculate the frequency response spectrum. The corresponding time domain responses are obtained through the inverse Fourier transform. The theoretical calculations are validated through finite element analysis and an experimental study. The PWAS responses under the free, debonded and bonded CFRP conditions are investigated and compared. The results demonstrate that the amplitude and travelling time of wave packet can be used to evaluate the CFRP bonding conditions. The method can work on a baseline-free manner.

Vibration Control of Membrane with Tension Gradient Using Multiple Dynamic Absorber (다중 동흡진기를 이용한 장력구배를 갖는 박판의 진동 제어)

  • Park, Chong-Hyun;Kim, Sung-Dae;Kim, Won-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.5 s.98
    • /
    • pp.595-603
    • /
    • 2005
  • In this work, the multiple dynamic absorber( MDA ) is introduced to reduce several vibration modes of shadow mask simultaneously and its design method is developed from the theory of the simple dynamic absorber. When designing the dynamic absorber, there are three significant design parameters such as mass, damping ratio and tuning frequency. Therefore the sensitivity analysis for those parameters has been executed in order to find out the design criteria of multiple dynamic absorber using the finite element model of shadow mask. The multiple dynamic absorber(MDA) designed by the proposed method is tested theoretically and experimentally to estimate the efficiency of vibration reduction. From the results, it is verified that the method is feasible to apply the system having the multiple nitration modes and more efficient than the thin wire-type damper used commercially to reduce the vibration of shadow mask.

Design and Analysis of Fuzzy PID Controller for Control of Nonlinear System (비선형 시스템 제어를 위한 퍼지 PID 제어기의 설계 및 해석)

  • Lee, Chul-Heui;Kim, Sung-Ho
    • Journal of Industrial Technology
    • /
    • v.20 no.B
    • /
    • pp.155-162
    • /
    • 2000
  • Although Fuzzy Logic Controller(FLC) adopted three terms as input gives better performance, FLC is in general composed of two-term control because of the difficulty in the construction of fuzzy rule base. In this paper, a three-term FLC which is similar to PID control but acts as a nonlinear controller is proposed. To reduce the complexity of the rule base design and to increase efficiency. a simplified fuzzy PID control is induced from a hybrid velocity/position type PID algorithm by sharing a common rule base for both fuzzy PI and fuzzy PD parts. It is simple in structure, easy in implementation, and fast in calculation. The phase plane technique is applied to obtain the rule base for fuzzy two-term control and the resultant rule base is Macvicar-Whelan type. And the membership function is a Gaussian function. The frequency response information is used in tuning of the membership functions. Also a tuning strategy for the scaling factors is proposed based on the relationship between PID gain and the scaling factors. Simulation results show better performance and the effectiveness of the proposed method.

  • PDF

A Practical Tuning Method of Dual-Input PSS and its Application to Large Power System (다중-입력 PSS의 실제적인 튜닝 방법과 대형 전력 시스템에의 적용)

  • Kim, Dong-Joon;Moon, Young-Hwan;Hur, Jin;Shin, Jeong-Hoon;Kim, Tae-Kyun;Choo, Jin-Boo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.7
    • /
    • pp.362-370
    • /
    • 2002
  • This paper describes the practical tuning method of dual-input PSS and its application to Muju P/P #2 with Proto PSS, which is based on DSP technology and uses both frequency and power. First, the model parameters of generator system used in this paper have been derived from the generator characteristic testing. Then, in the selection of PSS parameters, the Bode plot is plotted in order to tune the PSS's time constants which are able to compensate the phase lagging due to generator and excitation system. In addition, the eigenvalue analysis is also performed for determining a reliable PSS gain, $K_{s}$. Finally, the transient stability program has been utilized to verify the safe operation of Proto PSS against the predictable disturbances such as the AVR-step test and generator unloading test. In on-site test, the simulated results have been identically duplicated by implementing AVR step test in Muju P/P #2 with Proto PSS, which has the previously designed PSS parameters.s.

Studies on control mechanism and performance of a novel pneumatic-driven active dynamic vibration absorber

  • Kunjie Rong;Xinghua Li;Zheng Lu;Siyuan Wu
    • Structural Engineering and Mechanics
    • /
    • v.87 no.2
    • /
    • pp.117-127
    • /
    • 2023
  • To efficiently attenuate seismic responses of a structure, a novel pneumatic-driven active dynamic vibration absorber (PD-ADVA) is proposed in this study. PD-ADVA aims to realize closed-loop control using a simple and intuitive control algorithm, which takes the structure velocity response as the input signal and then outputs an inverse control force to primary structure. The corresponding active control theory and phase control mechanism of the system are studied by numerical and theoretical methods, the system's control performance and amplitude-frequency characteristics under seismic excitations are explored. The capability of the proposed active control system to cope with frequency-varying random excitation is evaluated by comparing with the optimum tuning TMD. The analysis results show that the control algorithm of PD-ADVA ensures the control force always output to the structure in the opposite direction of the velocity response, indicating that the presented system does not produce a negative effect. The phase difference between the response of uncontrolled and controlled structures is zero, while the phase difference between the control force and the harmonic excitation is π, the theoretical and numerical results demonstrate that PD-ADVA always generates beneficial control effects. The PD-ADVA can effectively mitigate the structural seismic responses, and its control performance is insensitive to amplitude. Compared with the optimum tuning TMD, PD-ADVA has better control performance and higher system stability, and will not have negative effects under seismic wave excitations.

Polar Transmitter with Differential DSM Phase and Digital PWM Envelope

  • Zhou, Bo;Liu, Shuli
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.3
    • /
    • pp.313-321
    • /
    • 2014
  • A low-power low-cost polar transmitter for EDGE is designed in $0.18{\mu}m$ CMOS. A differential delta-sigma modulator (DSM) tunes a three-terminal voltage-controlled oscillator (VCO) to perform RF phase modulation, where the VCO tuning curve is digitally pre-compensated for high linearity and the carrier frequency is calibrated by a dual-mode low-power frequency-locked loop (FLL). A digital intermediate-frequency (IF) pulse-width5 modulator (PWM) drives a complementary power-switch followed by an LC filter to achieve envelope modulation with high efficiency. The proposed transmitter with 9mW power dissipation relaxes the time alignment between the phase and envelope modulations, and achieves an error vector magnitude (EVM) of 4% and phase noise of -123dBc/Hz at 400kHz offset frequency.

Adaptively tuned dynamic absorber

  • Kim, Tae-Hyun;Park, Young-Jin;Kim, Heung-Gi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.111.4-111
    • /
    • 2001
  • In this paper, an adaptively tuned dynamic absorber is proposed. The adaptively tuned dynamic absorber is a dynamic absorber whose stiffness is tuned so that the natural frequency of the absorber coincides with the operating or natural frequency estimated by an adaptive algorithm. The feature of this absorber is as follows. It has an electrodynamic device for the stiffness control. Using Lorenz´s force, it changes the stiffness by changing the applied current. The change of stiffness results in the natural frequency shift, because its mass and damping coefficient are fixed. We may reduce the vibration of the overall system by tuning the natural frequency of the dynamic absorber to the resonant frequency of the structure, when the dominant single tone oscilation occurs in the system ...

  • PDF

Dynamic Voltage and Frequency Scaling for Power-Constrained Design using Process Voltage and Temperature Sensor Circuits

  • Nan, Haiqing;Kim, Kyung-Ki;Wang, Wei;Choi, Ken
    • Journal of Information Processing Systems
    • /
    • v.7 no.1
    • /
    • pp.93-102
    • /
    • 2011
  • In deeply scaled CMOS technologies, two major non-ideal factors are threatening the survival of the CMOS; i) PVT (process, voltage, and temperature) variations and ii) leakage power consumption. In this paper, we propose a novel post-silicon tuning methodology to scale optimum voltage and frequency "dynamically". The proposed design technique will use our PVT sensor circuits to monitor the variations and based on the monitored variation data, voltage and frequency will be compensated "automatically". During the compensation process, supply voltage is dynamically adjusted to guarantee the minimum total power consumption without violating the frequency requirement. The simulation results show that the proposed technique can reduce the total power by 85% and the static power by 53% on average for the selected ISCAS'85 benchmark circuits with 45 nm CMOS technology compared to the results of the traditional PVT compensation method.

Hartley-VCO Using Linear OTA-based Active Inductor

  • Jeong, Seong-Ryeol;Chung, Won-Sup
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.465-471
    • /
    • 2015
  • An LC-tuned sinusoidal voltage-controlled oscillator (VCO) using temperature-stable linear operational transconductance amplifiers (OTAs) is presented. Its architecture is based on Hartley oscillator configuration, where the inductor is active one realized with two OTAs and a grounded capacitor. Two diode limiters are used for limiting amplitude. A prototype oscillator built with discrete components exhibits less than 3.1% nonlinearity in its current-to-frequency transfer characteristic from 1.99 MHz to 39.14 MHz and $220ppm/^{\circ}C$ frequency stability to the temperature drift over 0 to $75^{\circ}C$. The total harmonic distortion (THD) is as low as 4.4 % for a specified frequency-tuning range. The simulated phase noise of the VCO is about -108.9 dBc/Hz at 1 MHz offset frequency in frequency range of 0.4 - 46.97 MHz and property of phase noise of VCO is better than colpitts-VCO.

Advanced SOGI-FLL Scheme Based on Fuzzy Logic for Single-Phase Grid-Connected Converters

  • Park, Jin-Sang;Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.598-607
    • /
    • 2014
  • This paper proposes a frequency-locked loop (FLL) scheme for a single-phase grid-connected converter. A second-order generalized integrator (SOGI) based on fuzzy logic (FL) is applied to this converter to achieve precise phase angle detection. The use of this method enables the compensation of the nonlinear characteristic of the frequency error, which is defined in the SOGI scheme as the variation of the central frequency through the self-tuning gain. With the proposed scheme, the performance of the SOGI-FLL is further improved at the grid disturbances, which results in the stable operation of the grid converter under grid voltage sags or frequency variation. The PSIM simulation and experimental results are shown to verify the effectiveness of the proposed method.