• 제목/요약/키워드: Frequency analyzer

검색결과 616건 처리시간 0.026초

공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구 (A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS)

  • 박철;임주환;조인호;임헌송
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

Mica/Epoxy 복합 절연계통의 부분방전 특성과 열화 관계에 관한 연구(I) (A Study on the Relationship between Aging and Partial Discharge Characteristics of the Mica/Epoxy Composite Insulation Systems (l))

  • 강동식;이우영;박정후;곽영순;김길용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.976-979
    • /
    • 1992
  • There are lots of problem which are delaminations and partial discharge of insulation materials in high-voltage rotating machines caused by mechanical, electrical and thermal aging. Several experiments have been aiming at finding the useful diagnostic parameters from the partial discharge characteristics by applying a new measurement techniques. This paper deals with the partial discharge characteristics (pulse height, pulse angle, pulse frequency spectrum and time interval), which may be a useful diagnostic concept in predicting insulation condition of mica/epoxy composite insulation materials, by using several measurement equipments (frequency spectrum analyzer. multichannel analyzer and time interval analyzer).

  • PDF

1-10 ㎓ 초고주파 패키지용 bonding wire 인덕턴스 특성 측정 (Inductance Characterization of Bonding Wires for 1-10㎓ Radio Frequency Packages)

  • 정태호;지용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.221-224
    • /
    • 2001
  • In this paper, the bonding wire interconnection has been studied from the points of view of modeling and electrical characterization. The bonding wire is measured by TDR(Time Domain Reflectometry) and Network analyzer(1-10㎓). First, one gold bonding wire mounted on 2mm gap substrate measured 3.68nH by TDR and 3.39nH by Network analyzer(6㎓). Two gold bonding wire mounted on 2mm gap substrate measured 3.14nH by TDR and 2.80nH by Network analyzer. This result presented that inductance of bonding wire could be employed as inductors for radio frequency circuit packaging.

  • PDF

수력 발전기 권선에서의 운전중 부분방전 측정기법 (On-line partial discharge measurement techniques of hydro-generator windings)

  • 황동하;김진봉;김용주;박명수;김택수
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.294-300
    • /
    • 1996
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current and .DELTA.tan.delta. tests has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot dischages may not be found with off-line diagnoses. This paper introduces the on-line partial discharge measurement techniques using frequency spectrum analyzer(FSA) for the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

치과용 고주파 주조기를 이용한 Co-Cr-Mo계 합금 용해과정의 적외선 열화상 분석 (Analysis of infrared thermal image for melting processes of Co-Cr-Mo based alloy using high frequency induction casting machine)

  • 강후원;박영식;황인;이창호;허용;원용관
    • 대한치과기공학회지
    • /
    • 제36권3호
    • /
    • pp.149-158
    • /
    • 2014
  • Purpose: Dental casting Co-Cr-Mo based alloys of five kinds of ingot type and two kinds of shot type were analyzed the melting processes with heating time of high frequency induction centrifugal casting machine using infrared thermal image analyzer. Methods: When Co-Cr-Mo based alloys were put about 30g/charge in the ceramic crucible of high frequency induction centrifugal casting machine and heat, Infrared thermal image analyzer and IR thermometer indicated these alloys in the crucible were set and operated. Results: The melting temperatures of alloys measuring infrared thermal image analyzer were deviated ${\pm}10^{\circ}C$ compared to those of manufacturing company. On the other hand, the melting time of alloys were differently appeared with the shape of alloys(ingot and shot type). Conclusion: The melting temperatures of dental Co-Cr-Mo based alloys were measured the degree of $1,360{\sim}1410^{\circ}C$ and the heating time with the alloys of ingot and shot type were deviated ${\pm}10sec$.

Acoustic Emission(AE)을 이용한 복합재료 구조물의 비파괴 특성 연구 (A study on the non-destructive characteristics of the composite structures using the Acoustic Emission)

  • 이창훈;최진호;권진회;변준형;유연호
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.139-142
    • /
    • 2004
  • As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the study on the non-destructive testing methods of the composite materials has become an important research area for improving their reliability and safety. In this paper, the AE signal analyzer with the resonance circuit to extract the specified frequency of the acoustic emission signal were designed and fabricated. The noise levels of the fabricated AE signal analyzer by the disturbance such as impact or mechanical vibration had a very small value comparable to those of the conventional AE signal analyzer. Also, the crack detection capabilities of the fabricated AE signal analyzer under the static and dynamic tensile test were evaluated and compared with the conventional AE signal analyzer.

  • PDF

LabView 기반 부분방전 분석장치의 설계 및 제작 (Design and Fabrication of a LabView Based Partial Discharge Analyzer)

  • 차현규;이정윤;박대원;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제25권3호
    • /
    • pp.229-235
    • /
    • 2012
  • This paper dealt with the fabrication of a partial discharge (PD) analyzer for insulation diagnosis of power facilities like transformers, cables and gas-insulated switchgears. An analytic algorithm for the phase (${\phi}$), the magnitude (q), and the pulse count (n) of PD pulse was designed and a time-frequency (TF) map algorithm was applied in the system to eliminate noises by analyzing the time and the frequency component of signals. All the algorithms were operated by a LabView graphical program. The detection circuit consists of a coupling capacitor, a detection impedance, and a low noise amplifier. A plane-plane and a point-plane electrode system were fabricated to simulate different types of insulation defects. In the experiment, we could easily understand the characteristics of PD pulses using the prototype PD analyzer.

벡터 회로망 분석기 측정을 기반으로 한 3상 변압기의 시간영역 펄스 신호에 대한 응답 분석 (The Response to Impulse Signal on Three Phase Transformer using Vector Network Analyzer)

  • 김광호;정종만;나완수
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.79-84
    • /
    • 2015
  • Transformer is widely used element on power system and industrial area. Especially the transformers installed at power system are exposed to an environment of arbitrary changed. Thus the prediction of degradation and the analysis of response to impulse are important. To conduct those works, the electrical characteristics of system should be analyzed, effectively. But the analysis of electrical characteristic in electric machine level such as pole and pad-mounted transformer is almost no, thus commercial VNA (Vector Network Analyzer) is used to getting the response in wide frequency range. However, the output power of VNA is usually under 10mW, so verification for effectiveness of measuring electrically large component should be conducted, firstly. Next, after getting total S-parameter of transformer, predicting impulse response can be performed in time-domain with circuit simulator. In this paper, it is introduced that verification effectiveness of VNA using transfer function from SFRA (Sweep Frequency Response Analyzer), firstly. Next, total S-parameter, six by six matix form, was built using measured 2 port S-parameter from vector network analyzer. To get the response to impulse which is defined by IEC 60060-1, time-domain simulation is conducted to ADS (Advenced Design System) circuit simulator.

전류모드제어를 적용한 직류전원장치의 해석 및 보상에 관한 연구 (The Analysis and Compensation of DC to DC Converter with Current Mode Controller)

  • 김철진;김영태;송요창
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권5호
    • /
    • pp.230-237
    • /
    • 2003
  • Current mode control has been used for DC to DC converters for over twenty years. There are many different control schemes which use the inductor current signal in one way or another to control the DC to DC converter. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the guarantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test result. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency fc is early 1/5 of switching frequency, fs, from the experimental result with frequency response analyzer.

고분자감응성 LB막의 유변학적인 특성을 이용한 가스센서 연구 (The Study of Gas Sensor Using Rheological Properties of Polymeric Sensitive LB Films)

  • 강현욱;김정명;권영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.198-201
    • /
    • 1997
  • The new system for identification of organic vapours and analysis method of mechanism between organic vapours and sensitive materials were attempted using the resonant resistance and resonant frequency of Quartz Crystal Analyzer (Q. C. A.). The resonant resistance shift means rheological changes in sensitive LB films occurred by the adsorption of organic vapours, while the resonant frequency shift represent the mass of organic vapour loaded in or on the sensitive LB films. It is thought that we can obtain more accurate response mechanism of organic vapour using the resonant frequency and resonant resistance diagram. The polymeric sensitive material were quantitively depositied using the LB method. In the experimental results, the adsorption behavior of organic vapour response can be decided by two type ; surface adsorption and penetration into sensitive material. Organic vapours had different positions in the Frequency-Resistance (F-R) diagram as to the kinds and concentrations of organic vapours. Thus F-R diagram can be applied to the development of one channel gas sensing system using the Quartz Crystal Analyzer.

  • PDF