• Title/Summary/Keyword: Frequency Recovery

Search Result 676, Processing Time 0.025 seconds

Non-Data-Aided Spectral-Line Method for Fine Carrier Frequency Synchronization in OFDM Receivers

  • Roh, Heejin;Cheun, Kyungwhoon
    • Journal of Communications and Networks
    • /
    • v.6 no.2
    • /
    • pp.112-122
    • /
    • 2004
  • A nonlinear spectral-line method utilizing the fourth absolute moment of the receiver discrete Fourier transform output is proposed as a non-data-aided fine carrier frequency synchronization algorithm for OFDM receivers. A simple modification of the algorithm resulting in low implementation complexity is also developed. Analytic expressions are derived for the steady-state frequency error variances of the algorithms and verified to be very accurate via computer simulations over AWGN and frequency selective multipath channels. Numerical results show that the proposed algorithms provide reliable and excellent steady-state performance, especially with PSK modulation. Also, the proposed algorithms are insensitive to symbol timing offsets, only requiring a coarse symbol timing recovery.

Power Spectal Analysis of Masticatory Muscles during Sustained Isometric Contraction and Recovery at Various Contraction Times (저작근의 등척성 수축시간 변화에 따른 Power Spectrum 분석에 관한 연구)

  • Wook Kim;Heung-Sang Lee;Young-Ku Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.269-281
    • /
    • 1995
  • To study the characteristics of EMG power spectrum of masticatory muscles during sustained isometric contraction and recovery at various contraction times, the author analysed the EMG signals of anterior temporal and masseter muscles before, during, and after sustained isometric contraction at 50% level of maximum voluntary contraction (MVC) for 15,30,60 seconds. Twelve normal subjects were included in this study. The author came to following conclusions from the results. 1. MMF of anterior temporal muscle in the contraction period was significantly higher than that of masseter muscle during sustained isometric contraction regardless of isometric contraction times (p<0.05). 2. MMF in the contraction period decreased as the contraction time increased during sustained isometric contraction in both temporal and masseter muscles(p<0.05). 3. SMF in the contraction period increased as the contraction tie increased during sustained isometric contraction in both temporal and masseter muscles(p<0.01). 4. MMF in the first part of recovery period (20 seconds) decreased as the contraction time increased during sustained isometric contraction(p<0.05). However, MMF in the later parts of recovery period (20-120 seconds) showed no significant differences. 5. MMF of anterior temporl muscle in the recovery period was significantly higher than that of masseter muscle after sustained isometric contraction regardless of isometric contraction times (p<0.05). 6. The recovery rate of MF reached 100% in 100 seconds after the isometric contraction regardless of isometric contraction times.

  • PDF

The syllable recovrey rule-based system and the application of a morphological analysis method for the post-processing of a continuous speech recognition (연속음성인식 후처리를 위한 음절 복원 rule-based 시스템과 형태소분석기법의 적용)

  • 박미성;김미진;김계성;최재혁;이상조
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.3
    • /
    • pp.47-56
    • /
    • 1999
  • Various phonological alteration occurs when we pronounce continuously in korean. This phonological alteration is one of the major reasons which make the speech recognition of korean difficult. This paper presents a rule-based system which converts a speech recognition character string to a text-based character string. The recovery results are morphologically analyzed and only a correct text string is generated. Recovery is executed according to four kinds of rules, i.e., a syllable boundary final-consonant initial-consonant recovery rule, a vowel-process recovery rule, a last syllable final-consonant recovery rule and a monosyllable process rule. We use a x-clustering information for an efficient recovery and use a postfix-syllable frequency information for restricting recovery candidates to enter morphological analyzer. Because this system is a rule-based system, it doesn't necessitate a large pronouncing dictionary or a phoneme dictionary and the advantage of this system is that we can use the being text based morphological analyzer.

  • PDF

A Study of Trunk Muscle Fatigue and Recovery Time during Isometric Extension Tasks (허리 폄 동작시 발생하는 근육피로 회복시간 연구)

  • Kim, Jeong-Ryong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.25-33
    • /
    • 2002
  • The purpose of study is to investigate the relationship between the trunk muscle fatigue and recovery time during repetitive extension by using a surface electromyogram(EMG). Ten healthy subjects particioated in a simulated lifting task with five levels of recovery time and three levels of sub-maximal contraction. EMG signals of the L1(Lumbar 1st Vertebrae) and L3(Lumbar 3rd Vertebrae) level of the erector spinae muscle were recorded. and analyzed in terms of MPF(mean power frequency) parameter to quantify the level of muscle fatigue. It was found that MPF significantly (p<0.05) decreased during repetitive extension task at 50% and 75% sub-maximal contractions. Then it took minutes for the trunk muscle to recover from fatigue during 50% sub-maximal contraction. and it took five minutes during 75% sub-maximal contraction. and it took five minutes during 75% sub-maximal contraction. The recovery time estimated by the maximum force needs to be re-evaluated for the trunk muscle to fully recover from fatigue. In conclusion. the work/rest cycle needs to be studied based upon the information of muscle fatigue in order to prevent workers from musculoskeletal injuries during repetitive lifting task.

The Effect of Electroacupuncture on Concentration and Activity of CK, ALP, and IgG in Serum and Central Nervous System of Rats (전침자극이 중추신경계 손상 흰쥐에서 CK, ALP, IgG 효소활성도에 미치는 영향)

  • Ha, Mi-Sook;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.2
    • /
    • pp.47-53
    • /
    • 2010
  • Purpose: This study investigated the effect of electroacupuncture stimulation on changes in blood biochemistry in spinal cord injury (SCI) rats whose cords were damaged by 6-hydroxydopamine (6-OHDA). Methods: Twenty-one Sprague-Dawley adult male rats were assigned to one of three groups: normal (n=7), control (n=7) and experimental group (n=7). The experimental group received electroacupuncture (Es-160, ITO, Japan) for 15 minutes in the form of low frequency (2 Hz) stimulation to the zusanli point. After treatment, we observed motor behavior recovery using the inclined plane test. We also measured serum and CNS concentrations and activities of enzymes including creatine kinase (CK), alkaline phosphatase (ALP), and Immunoglobulin G (IgG). Statistical analysis was done using one-way analysis of variance (ANOVA). Results: Concentrations of CK, ALP and IgG were lower in the experimental group than in the control group. Functional recovery was evaluated by the maximal angle of the inclined board on which rats could maintain their initial position. This allowed us to monitor progressive locomotor recovery. The maximal angles of the inclined plane test were higher in the experimental group than in the control group (p<0.05). Conclusion: The results of this study showed that electroacupuncture to the zusanli point has a therapeutic effect on functional recovery after SCI.

Design of a High Speed QPSK/16-QAM Receiver Chip (고속 QPSK/16-QAM 수신기 칩 설계)

  • Park, Ki-Hyuk;Sunwoo, Myung-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.4B
    • /
    • pp.237-244
    • /
    • 2003
  • This paper presents the design of a QPSK/16-QAM downstreams receiver chip. The proposed chip consists of a blind equalizer, a timing recovery block and a carrier recovery block. The blind equalizer uses a DFE sturucture using CMA(Constant Module Algorithm). The symbol timing recovery uses the modified parabolic interpolator. The decision-directed carrier recovery is used to remove the carrier frequency offset, phase offset and phase jitter. The implemented LMDS receiver can support four data rates, 10, 20, 30 and 40 Mbps and can accommodate the symbol rate up to 10 Mbaud. This symbol rate is faster than existing QAM receivers.

Design of Carrier Recovery Loop for Receiving Demodulator in Digital Satellite Broadcasting (디지털 위성방송 수신용 복조기를 위한 반송파 복원 회로 설계)

  • 하창우;이완범;김형균;김환용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11B
    • /
    • pp.1565-1573
    • /
    • 2001
  • In order to resolve problems according to the phase error in QPSK demodulator in the digital satellite broadcasting, the demodulator requires carrier recovery loop which searches for the frequency and phase of the carrier. In this paper the drawback of NCO of the conventional carrier recovery loop is to wastes a amount of power for the structure of Look-up table , we designed the structure of combinational logic without the Look-up table. In the comparison with dynamic power of the proposed NCO, the power of NCO with the Look-up table is 175[${\mu}$W], NCO with the proposed structure is 24.65[${\mu}$W]. As the result, it is recognized that loss power is reduced about one eighth. In the simulation of carrier recovery loop designed QPSK demodulator, it is known that the carrier phase is compensated.

  • PDF

Effects of Electroacupuncture on Activity of GOT, GPT, LDH and Functional Recovery in the Motor Injury Rats by the 6-hydroxydopamine (6-hydroxydopamine에 의한 운동손상 흰 쥐에서 전침이 GOT, GPT, LDH 활성도 및 기능회복에 미치는 영향)

  • Ha, Mi-Sook;Rho, Min-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.2
    • /
    • pp.265-272
    • /
    • 2010
  • Purpose : This study was investigated the effect of electroacupuncture stimulation on the change of blood biochemical components in the rat spinal cord injury(SCI) damaged by the 6-hydroxydopamine. Methods : SCI model rats were damaged in L1-L2 injected with 6-hydroxydopamine. The thirty Sprague-Dawley adult male rats were randomly divided into normal group, control group and electroacupuncture group. Experimental groups were applied as electroacupuncture(Es-160, ITO, Japan) for 15minutes during the low frequency(2 Hz) stimulation to zusanli. The enzyme concentration levels analysis of the hematological changes were measured of Glutamate Oxaloacetate Transaminase(GOT), Glutamate Pyruvate Transaminase(GPT), Lactate dehydrogenase(LDH) and motor function recovery change was evaluated by the rota-rod test. Results : This study were as follow : The concentration of GOT, LDH in experimental group was lower than control group(p<.05). The experimental group showed increase of motor function recovery more in compared to control group(p<.05). Conclusion : The results of this study showed that electroacupuncture to zusanli point have an effect on functional recovery after the 6-hydroxydopamine induced SCI in rats.

16-QAM Demodulator Design of Broadband Wireless Local Loop (광대역 무선가입자망용 16-QAM 복조기 설계)

  • 김남일;김응배;이창석
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.81-84
    • /
    • 2000
  • This paper has been studied the design of 16-QAM demodulator used in broadband wireless local loop subscriber station. In B-WLL systems, transmission signal experience the inter symbol interference(ISI) due to multipath, frequency offset of RF/IF local oscillator and phase offset. In this paper, we discuss the effective data recovery algorithm for 16-QAM demodulator to compensate the distorted signal from ISI, frequency offset and phase offset.

  • PDF

An Improved ZVZCS PWM FB DC/DC Converter Using the Modified Clamp Circuit (개선된 Clamp Circuit 적용 ZVZCS FB DC/DC 컨버터)

  • 김은수;조기연;김윤호;이진수
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.643-645
    • /
    • 1999
  • The conventional high frequency phase-shifted full bridge dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval. Due to this circulating current, RMS current stress, conduction losses of transformer and switching devices are increased. To alleviate this problem, this paper provides a circulating current free type high frequency soft switching phase-shifted full bridge (FB) dc/dc converter with the modified energy recovery snubber (ERS) attached at the secondary side of transforemr.

  • PDF