• Title/Summary/Keyword: Foundation soil

Search Result 1,113, Processing Time 0.024 seconds

Parametric study of piled raft for three load-patterns

  • Sawant, V.A.;Pawar, S.V.;Ladhane, K.B.
    • Coupled systems mechanics
    • /
    • v.1 no.2
    • /
    • pp.115-131
    • /
    • 2012
  • Paper presents an improved solution algorithm based on Finite Element Method to analyse piled raft foundation. Piles are modelled as beam elements with soil springs. Finite element analysis of raft is based on the classical theory of thick plates resting on Winkler foundation that accounts for the transverse shear deformation of the plate. Four node, isoparametric rectangular elements with three degrees of freedom per node are considered in the development of finite element formulation. Independent bilinear shape functions are assumed for displacement and rotational degrees of freedom. Effect of raft thickness, soil modulus and load pattern on the response is considered. Significant improvement in the settlements and moments in the raft is observed.

Structural Vibration Analysis of a Large Two-Stroke Engine and Foundation System for Stationary Power Plants (발전용 대형 2 행정 디젤 엔진 및 기초의 구조 진동해석)

  • 박종포;신언탁
    • Journal of KSNVE
    • /
    • v.10 no.3
    • /
    • pp.493-499
    • /
    • 2000
  • Structural vibration analysis of the stationary power plant system employing a large two-stroke low speed diesel engine is performed to verify that the vibration characteristics of the system meet design requirements, The system consists of the diesel engine generator and concrete foundation including pile and soil. The system is modeled in the form of a mass-elastic system of 5 degrees of freedom for vibration analysis. Excitation moments and dynamic parameters including engine body stiffness soil stiffness and damping are identified for the analysis, Results of structural vibration analysis of the system are presented and compared with measurements in this paper.

  • PDF

Field Application Study for Soil Improvement and Existing Foundation Protection Work by Hi-FA(High performance and Multi functional Agent) (Hi-FA(유동성 및 점성 개질제)를 이용한 지반보강 및 기존 교량기초 보강공법에 대한 실용화 연구)

  • Kim, Myung-Hak;Park, Myoung-Deuk;Yoon, Tae-Gook;Lee, Yong-Jun;Park, Min-Cheol
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.664-675
    • /
    • 2010
  • Recently environment-friendly construction method is major trend in both domestic and world constrction fields. In this paper High Functional Performance Agent(Hi-FA) which has various improved engineering characteristics different with conventional Portland cement grouting, such as high viscosity, liquidity, void filling ability, early hardening, and separation resistance, was analyzed by field and laboratory test. Also soil improvement and existing deep foundation protection works were performed and analyzed using Hi-FA.

  • PDF

A Study on the Suitability of Suction Caisson Foundation for the 5Mw Offshore Wind Turbine (5MW급 해상풍력발전시스템용 Suction Caisson 하부구조물 적합성 연구)

  • Kim, Yong-Chun;Chung, Chin-Wha;Park, Hyun-Chul;Lee, Seunug-Min;Kwon, Dae-Yong;Shi, Wei
    • New & Renewable Energy
    • /
    • v.6 no.3
    • /
    • pp.47-54
    • /
    • 2010
  • Foundation plays an important role in the offshore wind turbine system. Different from conventional foundations, the suction caisson is proven to be economical and reliable. In this work, three-dimensional finite element method is used to check the suitability of suction caisson foundation. NREL 5MW wind turbine is chosen as a baseline model in our simulation. The maximum overturning moment and vertical load at the mudline are calculated using FAST and Bladed. Meanwhile the soil-structure interaction response from our simulation is also compared with the experiment data from Oxford university. The design parameter such as caisson length, diameter of skirt and spacing of multipod are investigated. Accordingly based on these parameters suggestions are given to use suction caisson foundations more efficiently.

Model Test and Deformation Analysis of the Improved Soft Foundation(I) (개량연약지반의 모형실험과 변형해석(I))

  • 이문수;이진수;오재화
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.2
    • /
    • pp.67-78
    • /
    • 1994
  • This is a fundamental study aiming at scrutinizing the effect of reinforcement and deformation characteristics of soft clayey foundation improved by vanous technical treatments. Among many methods proposed thus far, geotextile was selected for the purpose of improvement of the model soil foundation on which plate loading test was subsequently performed. Loading test has been carried out with the variation of the location and number of covering layers of geotextile, and actual values for ground deformation and geotextile effect were secured. As for technique on deformation analysis, elasto-plastic model for soil, elastic model for sand, and beam theory for geotextile were coupled with satisfactory results between observed and numerical values.

  • PDF

The Evaluation of the Allowable Bearing Capacity of Foundations using N-Value (N-Value를 이용한 기초의 지지력 산정)

  • 이강운;박택규;정해운
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10a
    • /
    • pp.281-292
    • /
    • 2001
  • The evaluation of the allowable bearing capacity is the most important step in the design of a foundation. An accurate evaluation of the effect of all factors such as the physical properties of the soil located beneath the area, the size of the area, the depth of foundation, and the position of the water table is impracticable Therefore, the designer is compelled to estimate the allowable bearing capacity on the basis of simple semiempirical rules under cohesionless soils. This paper deals with semiemperical rules for determining allowable bearing capacity based on observed relations between the results of standard penetration test. Additional comparisions between the results of the theoretical methods and the emperical rules are performed to suggest more conservative design for the engineer.

  • PDF

Dynamic Behaviour of Pile Foundation with Scour (세굴을 고려한 말뚝기초의 동적 거동분석)

  • 김정환;허택영;박용명
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.55-62
    • /
    • 2003
  • This study considered the effect of scour depth on the behaviour of pile foundation of bridge structure under seismic excitation. The numerical model was composed of the superstructure, pile foundation and soil. The superstructure and pile was modeled by beam elements and soil was by spring elements. The pile head and concrete footing was considered as hinge and rigid connected situation, respectively. A toro-gap element was used to model the expansion joint of superstructure. Nonlinear dynamic analysis was carried out on the constructed model. It was acknowledged that the steel pile become to yield after the scour depth reached about 2.0m.

  • PDF

On soil-structure interaction models to simulate free vibrations and behavior under seismic loads of a RC building supported by a particular shallow foundation

  • Soelarso Soelarso;Jean-Louis Batoz;Eduard Antaluca;Fabien Lamarque
    • Coupled systems mechanics
    • /
    • v.12 no.5
    • /
    • pp.461-479
    • /
    • 2023
  • The paper deals with the finite element modelling of the free vibration and structural behavior of a particular four-floor reinforced concrete structure subjected to static equivalent seismic loads and supported by a shallow foundation system called SNSF (Spider Net System Footing). The two FE models are a simple 2D Matlab model and a detailed 3D model based on solid elastic elements using Altairworks (Hypermesh and Optistruct). Both models can simulate the soil structure interaction. We concentrate on the behavior of a representative cell involving two columns on five levels. The influence of the boundary conditions on the external vertical planes of the domain are duly studied. The Matlab model appears relevant for a primary estimation of frequencies and stiffness of the whole structure under vertical and lateral loads.

Response of circular footing on dry dense sand to impact load with different embedment depths

  • Ali, Adnan F.;Fattah, Mohammed Y.;Ahmed, Balqees A.
    • Earthquakes and Structures
    • /
    • v.14 no.4
    • /
    • pp.323-336
    • /
    • 2018
  • Machine foundations with impact loads are common powerful sources of industrial vibrations. These foundations are generally transferring vertical dynamic loads to the soil and generate ground vibrations which may harmfully affect the surrounding structures or buildings. Dynamic effects range from severe trouble of working conditions for some sensitive instruments or devices to visible structural damage. This work includes an experimental study on the behavior of dry dense sand under the action of a single impulsive load. The objective of this research is to predict the dry sand response under impact loads. Emphasis will be made on attenuation of waves induced by impact loads through the soil. The research also includes studying the effect of footing embedment, and footing area on the soil behavior and its dynamic response. Different falling masses from different heights were conducted using the falling weight deflectometer (FWD) to provide the single pulse energy. The responses of different soils were evaluated at different locations (vertically below the impact plate and horizontally away from it). These responses include; displacements, velocities, and accelerations that are developed due to the impact acting at top and different depths within the soil using the falling weight deflectometer (FWD) and accelerometers (ARH-500A Waterproof, and Low capacity Acceleration Transducer) that are embedded in the soil in addition to soil pressure gauges. It was concluded that increasing the footing embedment depth results in increase in the amplitude of the force-time history by about 10-30% due to increase in the degree of confinement. This is accompanied by a decrease in the displacement response of the soil by about 40-50% due to increase in the overburden pressure when the embedment depth increased which leads to increasing the stiffness of sandy soil. There is also increase in the natural frequency of the soil-foundation system by about 20-45%. For surface foundation, the foundation is free to oscillate in vertical, horizontal and rocking modes. But, when embedding a footing, the surrounding soil restricts oscillation due to confinement which leads to increasing the natural frequency. Moreover, the soil density increases with depth because of compaction, which makes the soil behave as a solid medium. Increasing the footing embedment depth results in an increase in the damping ratio by about 50-150% due to the increase of soil density as D/B increases, hence the soil tends to behave as a solid medium which activates both viscous and strain damping.

Piled-Raft Foundation on Soft Clay in Gimhae Area (연약점토지반 Piled-Raft 기초의 김해지역에서의 적용성)

  • 서영교
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.20-25
    • /
    • 2004
  • For the structural foundation above the soft clay layer conditions, the design charts are first presented for the evaluation of both bearing capacity and total settlement in the basic raft foundation system. wad settlement relationship curves are used to evaluate the ultimate soil bearing capacity. The total settlement is evaluated by applying various traditional factors into the ultimate bearing capacity. Then, the parametric studies are carried out for the piled-raft foundation system. In the numerical analysis, the elasto-pastic finite element model(Mohr-Coulomb model) is used to present the foundation response and design charts, which enable the determination of the raft size and pile length and spacing.