• Title/Summary/Keyword: Formaldehyde(HCHO)

Search Result 123, Processing Time 0.031 seconds

Concentrations of VOCs and Formaldehyde in Newly Constructed Apartment Buildings Before and After Residence (신축공동주택의 입주전후 VOCs 및 HCHO 농도)

  • Park, Sang-Eun;Kim, Hyun-Wook;Sim, Sang-Hyo;Lee, Se-Hoon;Koo, Jung-Wan
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.2 s.95
    • /
    • pp.98-103
    • /
    • 2007
  • This study was performed to measure the changed concentrations of formaldehyde and volatile organic compounds after moving in the newly constructed apartment buildings at Seoul. From December 2004 to October 2005, we measured the concentration of formaldehyde and volatile organic compounds in newly constructed apartment buildings before and after residence. In conclusion, it showed that there was a significant relationship association between the con centration of the volatile organic compound and the formaldehyde and remodeling of the house, built in-furniture, and ventilation of the house. Therefore, it was suggested that we need preventive measures and management plans about various factors such. as remodeling, and built in-furniture, ventilation to decrease the concentrations of volatile organic compounds and formaldehyde.

A Study on the Free formaldehyde in Nonwoven Fabrics -with emphasis on the fusible bonded webs- (부직포 중에 잔존하는 유리 Formaldehyde에 관한 연구 -접착심지를 중심으로-)

  • Song Myoung Kyoun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.3 no.2
    • /
    • pp.9-14
    • /
    • 1979
  • As the fabric merchandises become more diversified and the pre-condensates of resin are used in increasing amount to enhance the quality of so-called 'easy care' in such fabric goods, form-aldehyde, which is extricated from nonwoven fabrics, has posed problems. The result of the study conformed, firstly that the fusible bonded webs sold in the current market contained a considerable amount of formaldehyde, i.e. the minimum of 552$\mu$g/g and the maximum of 2,123$\mu$g/g. Secondly, formaldehyde fond in many of such fabric goods was unable to be removed completely even after washed for, three times. Thirdly, the degree of permeation of HCHO into other part of the fabric proved to be high and. when kept in a poly bag over 10days. the amount of formaldehyde tended to increase. Such experiment, therefore, demonstrates that the methods of delivery and storage employed in the current distribution structure must be thoroughly re-examined. The conclusion of this study shows that we should be more concerned with the adverse effects of formaldehyde for the health of consumers. let alone the increase of export of such merchandises.

  • PDF

A Study on the Concentration Variations of VOCs and Formaldehyde on the Type of Interior Materials of New Vehicles by Simulation Program (시뮬레이션 프로그램을 이용한 신규 차량의 인테리어 물질에 따른 VOC와 폼알데히드의 농도 변화에 관한 연구)

  • Yi, Young-Seop;Kim, In-Bum;Ko, Won-Kyoung
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.89-95
    • /
    • 2012
  • The concentrations of Volatile Organic Compounds(VOCs) and Formaldehyde(HCHO) for interior materials of new vehicles are estimated and recognized by using the simulation program known as IAQx. The concentrations of contaminants are estimated and evaluated by the ventilation rates of new domestic vehicles and the required ventilation rates for new vehicles are estimated through the given contaminant data. This study is conducted to compare the ventilation rates for the contaminants between the discontinuously ventilated new vehicles and the continuously ventilated new vehicles using the simulation program. The equation of ventilation rate of new vehicles is acquired to be able to lower initial concentrations below the standard level under different conditions for both business and personal commuting.

The Study on Reduction of Hazardous Materials using Eco-friendly Charcoal Composite Sheet (친환경 활성탄 복합시트의 유해물질 저감 연구)

  • Choi, Il-Hong;Kang, Sang-Sik;Lee, Su-Min;Yang, Seung-Woo;Kim, Kyo-Tae;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.615-621
    • /
    • 2018
  • Recently, various environmentally friendly products have been developed for improving the indoor air quality while pursuing a well-being nature-friendly healthy life as a core value. In this research, we not only solve the problems of existing environmentally friendly paints, but also developed a charcoal composite seats that can reduce radon, which is a natural radioactive substance, and evaluated the reduction effect of radon, formaldehyde and volatile organic compounds. In the charcoal composite seats, a sodium silicate emulsion and charcoal were mixed to prepare an charcoal liquid coating material, and the composite seats was fabricated by air-spray coating method. In order to analyze the hazardous substance reduction performance of the fabricated charcoal composite seats, radon was designed to comply with the Ministry of the Environment standard, formaldehyde and volatile organic compounds were designed to comply with KCL-FIR-1085 standard. As a result of the experiment, the fabricated charcoal composite seats was evaluated as having a radon reduction capability of about 90.8% from 20 hours, formaldehyde and volatile organic compounds were 3 hours, and the reduction capability of 96.7% and 96.6% was found respectively. It is considered that these results can be utilized as basic data at the time of product development for improvement of indoor air quality.

Assessment of Indoor Air Quality of Classroom in School by Means of Source Generation - Case Study (발생원에 따른 일부 학교 교실의 실내공기질 평가 사례연구)

  • Yang Won-Ho;Byeon Jae-Cheol;Kim Young-Hee;Kim Dae-Won;Son Bu-Soon;Lee Jung-Eun
    • Journal of Environmental Science International
    • /
    • v.14 no.10
    • /
    • pp.979-983
    • /
    • 2005
  • Indoor air quality has been addressed as an important atmospheric environmental issue and has caught attention of the public in recent years in Korea. Good indoor air quality in classrooms favour student's learning ability, teacher and staff's productivity according to other studies. In this study, each classroom at four different schools was chosen for comparison of indoor and outdoor air quality by means of source generation types such as new constructed classroom, using of cleaning agents and purchased furniture. Temperature, relative humidity (RH), carbon dioxide $(CO_2)$, formaldehyde (HCHO), total volatile organic compounds (TVOCs) and particulate matter with diameter less than $10{\mu}m\;(PM_{10})$ were monitored at indoor and outdoor locations during lesson. HCHO was found to be the worst among parameters measured in new constructed classroom, HCHO and TVOCs was worst in classroom with new purchased furniture, and TVOCs was worst in classroom cleaned by cleaning agents, Indoor $(CO_2)$ concentrations often exceeded 1500 ppm indicating importance of ventilation. Active activity of students during break time made the $PM_{10}$ concentration higher than a lesson, Improvements and further researches should be carried out considering indoor air quality at schools is of special concern since children and students are susceptible to poor air quality.

Evaluation of Indoor Air Quality Improvement by Formaldehyde Emission Rate in School Indoor Environment Using Mass Balance (물질수지를 이용한 학교 실내환경의 포름알데히드(HCHO) 배출량 산정에 의한 실내공기질 개선 평가)

  • Yang, Won-Ho;Son, Bu-Soon;Kim, Dae-Won;Kim, Young-Hee;Byeon, Jae-Cheol;Jung, Soon-won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.160-165
    • /
    • 2005
  • Schools have significant and serious indoor environmental health problem, of which indoor air quality (IAQ) in school building may affect the health of the students and indirectly affect learning performance. Schools are of special concern when regarding indoor exposure to air pollutants, because students are particularly sensitive to pollutants and spend a significant amount of time in that environment. Therefore researches for improvement of indoor air quality have been developed such as installation of air cleaning device, ventilation system, titanium dioxide(TiO2) coating and so on. However, it is difficult to evaluate the magnitude of improvement of indoor air quality in field study because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. In this study, evaluation of reduction of formaldehyde emission rate in school indoor environments by far-Infrared ray coating material was carried out using mass balance model in indoor environment. we proposed the evaluation method of magnitude of improvement in indoor air quality, considering outdoor level and ventilation. Since simple indoor concentration measurements could not properly evaluate the indoor air quality, outdoor level and ventilation should be considered when evaluate the indoor air quality.

Formaldehyde Risk Assessment in Other Household Textile Products (가정용 섬유제품 중 기타 제품류의 폼알데하이드 위해성평가 연구)

  • Tae Hyun Park;Ji Hwan Song;Sa Ho Chun;Hee Rae Joe;Pil Jun Yoon;Ho Yeon Kang;Myeong Seon Ku;Jin Hyeok Son;Cheol Min Lee
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.2
    • /
    • pp.138-145
    • /
    • 2024
  • Background: Appropriateness issues have emerged regarding the non-application of hazardous substance safety standards for items classified as 'other textile products'. Objectives: Testing for formaldehyde (HCHO) and risk assessment were conducted on 'other textiles products' to provide reference data for promoting product safety policies. Methods: Testing was conducted on five items (102 products) classified as 'other textile products' according to relevant standards (textile products safety standards), and the risk of each product was assessed using the evaluation methodologies of the European Centre for Ecotoxicology and Toxicology of Chemicals (ECETOC) and European Chemical Agency (ECHA). Results: Out of the 102 products tested, HCHO was detected above the quantification limit in five. Based on these results, the screening risk assessment indicated that three products exceeded the criteria. Upon reassessing the emission and transfer rates of products exceeding the criteria, it was confirmed that there were no instances of exceeding the criteria. Conclusions: Risk assessment results can be used as supporting data for non-application of hazardous substance standards. However, it is deemed necessary to transition towards a management approach based on risks in order to addressing emerging trends such as convergence/new products.

A Study on the Calculation of Ventilation Rate in Apartment House according to VOCs and HCHO Substances of Building Material and Furniture (건축 마감재와 가구재의 VOCs, HCHO 유해물질에 따른 공동주택 적정 환기량 산정에 관한 연구)

  • Choi Jeong-Min;Park Jin-Seok;Son Young-Hwan;Park Chang-Sub;Park Min-Yong;Lee Kyung-Hee
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.101-108
    • /
    • 2005
  • Because of the airtightness of building, misuse of building materials and abuse of furniture, indoor air pollution problems have been increasingly concerned especially with apartment buildings. To improve the IAQ(Indoor Air Quality) in apartment building, this study was aimed at analyzing the factor of interior building material and furniture and calculating the ventilation rate of living room and bed room according to the surface area of interior building material and furniture in terms of VOCs(Volatile Organic Compounds) and HCHO(Formaldehyde). The results of this study are as follows; 1) In the concerned rooms, the living room has less pollution emission rate L(surface area/volume) than that of the bed room but, the living room needs more ventilation rate than that of the bed room because of built-in furniture in terms of VOCs and HCHO. 2) Built-in interior furniture is very important factor in IAQ problems of apartment building, but until now there is no provision about the built-in furniture, so that the provision must be regulated to control the IAQ. 3) To control the IAQ problem, the effective ventilation plans must be established according to the required ventilation rate by means of natural or mechanical ventilation method.

Differential Modification of Sperm Parameters by Various Volatile Organic Compounds

  • Choi, Dal-Woong;Sohn, Jong-Ryeul;Moon, Kyung-Whan;Byeon, Sang-Hoon;Yoo, Dong-Chul;Kim, Hi-Chol;Kim, Young-Whan
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.319-322
    • /
    • 2005
  • Porous building materials are not only sources of indoor air pollutants such as volatile organic compounds (VOCs) but they are also strong sinks of these pollutants. Volatile organic compounds have been implicated in impaired spermatogenesis, increase in the incidence of malformed sperm and decrease in the percentage of moving sperm. The aim of this study was to determine and compare the direct effects of various volatile organic compounds (phenol, formaldehyde; HCHO, ethanol, toluene, styrene) on motility and survival rate of human sperm in vitro. Semen samples from 3 health subjects were prepared using swim-up method and 1-10mM volatile organic compounds were added to the test medium. HCHO and phenol produced significant decreases in the motility and survival rate with a different potency. The most potent inhibition of motility and survival rate was observed after exposure to HCHO. Less than 1mM HCHO significantly inhibited sperm motility. When ethanol is added directly to sperm, at concentrations equivalent to that in serum after heavy drinking, these damaging effects were lowest compared with other volatile organic compounds. Present study shows that each compound has differential toxic potency to human sperm and we need special caution for the use of HCHO and phenol.

  • PDF

A study on the chemical emission of furnitures using the large chamber method (대형챔버에 의한 생활제품(가구류) 방출오염물질 특성연구)

  • Park, Jae-Hyoung;Knag, Yoon-Kyung;Lee, Yun-Gyu
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.742-747
    • /
    • 2008
  • Formaldehyde(HCHO) and total volatile organic compounds(VOCs) can cause adverse health effects to the building occupants and may contribute to symptoms of 'Sick Building Syndrome'. These chemical contaminants are emitted from furnishings and electronic equipments as well as building materials. The purpose of this study is to measure and analyze VOCs and HCHO emission concentration from furnitures composed of wood materials including various chemicals by the large chamber method. This paper presents experiment results on the emission concentration of TVOCs and HCHO released from furnitures, such as bed, kitchen, sofa and table by a large chamber($24m^3$). The temperature and air humidity in the chamber are controlled to $25{\pm}1{\circ}C$ and $50{\pm}5%$ for this experiment. When the air change rate is $0.5hr^{-1}$, the background concentrations within the large chamber are below $50{\mu}g/m^3$ for TVOC, $5{\mu}g/m^3$ for HCHO and individual VOCs. The study is investigated the characterization of the chemical emission TVOC and HCHO concentrations and unknown VOCs from 6 furnitures.

  • PDF