• 제목/요약/키워드: Formaldehyde(HCHO)

검색결과 123건 처리시간 0.026초

신축 공동주택에서의 강제환기장치 사용에 따른 실내공기질 개선효과 실증연구 (Experimental Study on the Effect of Ventilation System on Indoor Air Quality in New Apartment Buildings)

  • 이규동;박영석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.143-146
    • /
    • 2006
  • There has been growing concern regarding IAQ(Indoor Air Quality) recently, and IAQ problems from the air-tightness and use of chemical materials addition to the building materials have become increasingly important factors in the built environment. Ventilation is supposed as the solution of healthy indoor quality, and Korea government requests that all new apartment buildings must have a ventilation system as a matter of duty since January, 2006. The purpose of this study is to investigate the indoor concentration change of VOCs include the Formaldehyde according to many different ventilation supply types. Results showed that the reduction effect of target pollutants by the ventilation system was very slight. The cause of these results was attribute to increase the emission rate of building materials by increasing the ventilation rate.

  • PDF

신축 공동주택 및 건축자재에서의 오염물질 방출 특성 (A Study on the Emission Characteristics of Gaseous Organic Contaminants from Building Materials and Newly Constructed Apartments)

  • 김윤덕;이윤규
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.563-570
    • /
    • 2006
  • We investigated the emission characteristics of gaseous organic contaminants from building materials and newly constructed apartments. The emission test for building materials was done with small chamber method, and field measurements in newly constructed apartment were carried out by Korea Standard Test Method for Indoor Air Quality. First, the emission test by small chamber showed that the TVOC emission from building materials was much higher than formaldehyde. On the other hand, as expected, considerably high concentration of both TVOC and HCHO was detected in the new apartment.

광촉매공정과 필터를 이용한 흡연부스 공기정화연구 (Air Purification of Smoking Booth Using Photocatalytic Process and Air Filter)

  • 김태영;조영태;김재용
    • 공업화학
    • /
    • 제27권4호
    • /
    • pp.433-438
    • /
    • 2016
  • 본 연구에서는 CO, HCHO, $CH_3CHO$, PM10, PM2.5 등의 담배연기 내에 포함된 유해물질들의 농도를 지표로 광촉매와 필터로 구성된 공기정화장치를 부착한 흡연부스 내의 공기질을 평가하였다. 또한 광촉매에서 발생되는 OH 라디칼과 담배연기 내 가스상 유해물질들과의 반응성을 향상시켜 제거효율을 높이기 위해 적외선을 주사하였다. 공기정화장치와 필터를 활용한 흡연부스의 실험 결과, 시스템 가동 전보다 가스상 오염물질은 포름알데히드 포함 최대 85.2% 향상된 제거효율을 나타냈다. 처리 후의 미세먼지는 최대 89.4% 향상된 제거효율을 나타냈다.

합판 공장 부산물을 이용한 파티클보드의 물성에 관한 연구 - 표층 구성요소 및 파티클 전처리 여부에 따른 비교 - (Properties of Particleboard Using Byproduct of Plywood Manufacture - Evaluation on the Elements of Surface Layer and Pre-treatment of Particles)

  • 황정택;피덕원;강석구
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권1호
    • /
    • pp.33-41
    • /
    • 2013
  • 본 연구에서는 최근 파티클보드(Particle Board ; 이하 PB)의 원재료로 재활용되고 있는 목재 폐기물 중 합판공장의 부산물을 원재료로 사용하고 비포름알데히드계 EMDI접착제의 적용을 통한 제조조건을 최적화하여 재활용 원재료의 효과적인 활용을 통한 고(高)내수성 PB의 개발과 그에 대한 물리 기계적 특성을 규명하고자 하였다. 그 결과, (1) 베니어 적층 복합보드에 EMDI수지를 사용하였을 경우 휨 강도가 섬유방향 57.7 $N/mm^2$, 섬유 직각방향 25.1 $N/mm^2$의 강도를 나타내었다. (2) 두께팽윤율과 수분흡수율은 U형, M형, P형 실험에서 EMDI수지가 UF수지보다 높은 수준의 내수성을 나타내었다. (3) 잔존 포름알데히드의 양을 줄이고자 실행하였던 72시간 수침전처리는 파티클보드의 포름알데히드 방산량을 증가시키는 결과를 초래하였다.

호남지역의 다중이용시설별 실내공기질 실태 조사 (Indoor Air Quality in Various Type of Public Facilities at Honam Province)

  • 서병량;정만호;전준민
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

일부 수도권지역에서의 키즈카페 내 유해물질 노출수준 평가 (Assessment for Exposure Levels of Hazardous Substances in Kids Cafes within Some Metropolitan Area)

  • 김호현;안선민;이재영;최인석;이정훈;남의현;유시은;정다영;이철우;박충희
    • 한국환경보건학회지
    • /
    • 제45권1호
    • /
    • pp.54-61
    • /
    • 2019
  • Objectives: In this study, we investigated an assessment for exposure levels of hazardous substances to kids cafes that unregulated by law. Methods: Heavy metals, volatile organic compounds, formaldehyde, pesticides and phthalate were measured at 20 kids cafes in Gyeonggi-do and Incheon. Samplings were conducted from April to July in 2018. Results: Heavy metals were detected over the standard mainly around the floor and walls in the 19 kids cafes. Pesticides were detected in 7 locations with chlorpyrifos, diazinon and cypermethrin, and showed the highest detection level of chlorpyrifos. The concentrations of DEHP in all kids cafes were exceeded with standard. The risk assessment results showed that HCHO as carcinogen had a safety level and DEHP as non-carcinogens had a safety level as assessed to be under than 0.1. Conclusions: Considering the exposure investigation results and the importance of child health protection, kids cafe should be included in the legal management list of children's activities zones.

광촉매 건축자재와 환기시스템 적용에 따른 건축 환경 개선 방안 (Improvement of the Architectural Environment by Applying Photocatalyst Building Materials and Ventilation Systems)

  • 송용우;김성은;임세현;심성진
    • 토지주택연구
    • /
    • 제14권4호
    • /
    • pp.103-110
    • /
    • 2023
  • 하루 평균 대부분을 실내에서 보내는 현대인들은 내외부적으로 발생하는 실내오염물질에 지속적으로 노출되고 있다. WHO(World Health Organization) 2022년 보고서에 따르면 매년 세계적으로 약 700만명 이상의 사망 원인이 공기오염으로 실내오염물질의 심각성을 강조하고 있다. 대기오염물질 중에는 인체에 심각한 영향을 끼치는 질소산화물(NOx), 폼알데하이드(HCHO), 휘발성 유기화합물(VOCs) 등이 포함되는데, 이러한 실내공기 오염물질을 제거할 수 있는 물질로 광촉매가 있다. 광촉매는 미세먼지 전구물질 제거 성능뿐만 아니라 향균, 살균, 탈취 성능 또한 가지고 있어, 실내공기질 개선에 효과적이다. 이에, 본 연구에서는 광촉매를 건축물에 적용할 수 있는 부위 및 방안을 제시하였다. 적용 가능한 부위로는 내외장재, 콘크리트 등을 포함한 건축자재, 유기도료, 환기장치 등이 있으며, 각 부위에 최적 적용 방안에 대한 연구를 진행하였다.

서울시 일부 학교의 실내 공기질 조사 및 인식도 평가 (Assessment of Conscious Coginition Degree and Survey on the Indoor Air Quality at a public School in Seoul)

  • 손종렬;변상훈;김영환;김종혁;조윤수;이재영;박윤주
    • 환경위생공학
    • /
    • 제18권3호통권49호
    • /
    • pp.100-109
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and schools has been concern of people, scientists and related the public. And so in Seoul has recognized the healthy effect related to IAQ in schools. Therefore, the objective of this study reported in this article were to measure and compare the perception of IAQ of selected air pollutants at three different schools in Seoul. We performed a questionnaire survey of 400 students about their awareness for the importance of IAQ in our school. And we measured the IAQ of 3 schools considering as site region, construction year and studying level. The indoor air pollutants and parameters such as temperature, relative humidity, respirable particulate matter(PM10), formaldehyde(HCHO), total bacteria counts(TBC), carbon dioxide(CO$_2$), and noise were monitored in indoors. In results, all most response of occupant has recognized the awareness of IAQ at schools. The PMIO, TBC and Noise level of all schools were higher than the standard of the public 150 ${mu}$g/m$^3$ and 500CFU/m$^3$, the level formaldehyde(HCHO) was below 0.1 ppm of the healthy guideline of Korea And the concentration of CO$_2$ were investigated below 1,000 ppm of the standard implying ventilation in 2 schools except for 1 school(c school). Finally, the control of most important pollutants of IAQ in school were PM10, TBC and Noise. Therefore, it can be concluded that the indoor air quality of selected 3 schools studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems in schools, and all member relating school need to be effort to reduce the exposure of sources to undesirable indoor pollutants such as Particlate and Noise.

소형챔버를 이용한 건축자재 오염물질 방출시험방법 평가 (Evaluation of sampling and analytical method for emission experiment of pollutants in building materials using small chamber)

  • 이석조;장성기;김미현;이홍석;임준호;장미;서수연
    • 분석과학
    • /
    • 제18권4호
    • /
    • pp.344-354
    • /
    • 2005
  • 최근 들어 실내공기질 악화의 주 오염원인 건축자재에 대한 관심이 고조되면서 건축자재 오염물질 방출시험 자료 구축이 중요하게 됨에 따라, 신뢰성 있는 자료 확보를 위해 건축자재 방출시험 정도 관리에 대한 필요성이 대두되었다. 이에 본 연구는 건축자재 방출시험 성능에 대한 정도관리를 위해 총 휘발성 유기화합물과 포름알데히드에 대하여 기기분석 재현성, 회수율, 검출한계, 중복 및 반복채취 재현성, 파과용량 평가 등을 실시하였다. 기기분석 및 시료채취에 대한 재현성은 20~30% 이내의 양호한 결과를 보였으며, 회수율은 80% 이상으로 나타났으며, 파과 역시 일어나지 않아 소형챔버법에 의한 성능은 전반적으로 만족할 만한 수준을 보였다. 따라서, 소형챔버를 이용한 건축자재 오염물질 방출시험방법은 신뢰성있는 자료를 제공해 줄 수 있을 것으로 판단된다.

The Occupant Perception and Investigation of Indoor Air Quality at Home in Seoul

  • Sohn, Jong-Ryeul;Kim, Young-Whan;Byeon, Sang-Hoon
    • 환경위생공학
    • /
    • 제18권1호
    • /
    • pp.51-57
    • /
    • 2003
  • 최근 산업장 뿐만아니라 주택에서의 실내환경오염은 대단히 중요한 관심사이다. 특히 미국 EPA에서는 성인이 하루에 약 80 % 이상을 실내 공간에서 생활하고 있는 것으로 보고하고 있으며, 이러한 생환 방식의 변화에 인한 최근 도시화 지역에서의 실내 공기질(indoor air quality)의 문제가 새로운 환경 이슈로 부각되고 있고, 일본을 비롯한 구미 각 국에서도 21세기 환경문제 중 실내환경(indoor environment) 문제를 최우선으로 다루고 있다. 그러므로 본 연구에서는 주택에서의 실내공기질을 평가하기 위하여 설문지를 통하여 인식도를 조사하고 그를 토대로 6개의 다른 주거환경을 가진 주택을 대상으로 실내공기오염도를 측정하였다. 본 연구에서 평가한 측정항목은 온도, 습도, CO, $CO_2$, 호흡성분진, 포름알데히드, 총부유세균(TBC)이었으며, 주택의 지역 및 계절별로 나누어 측정하였는데, 측정결과 호흡성분진은 주택 5,6 에서 국내의 기준을 초과하였으며, 총부유세균은 흥콩과 싱가폴의 실내기준 권고치인 $500{\;}CFU/m^3$을 초과였고, HCHO는 모든 대상 주택에서 초과하였다. 또한 통계적으로 분석한 결과 주택의 건축년도와 CO, TBC가 0.01 수준에서 유의성 관계를 나타냈으며, 습도는0.05 수준에서 유의성을 나타냈다. 또한 주택의 거주자 500인을 대상으로 조사한 설문지 결과에서는 대부분 응답자가 실내공기오염에 대하여 인식하고있으며, 실내오염으로 인해 피로>두통>눈 아픔>기침 등을 호소하고 있으며, 실내공기정화장치가 필요하다고 응답하였다. 결론적으로 본 연구의 목적은 주택에서의 실내공기질을 평가하여 실내공기질의 중요성을 인식시키고, 그에 대한 구체적인 대책방안을 제시하여 관련 기준을 준비하는데 기초적인 자료를 마련하고 주민들이 쾌적한 삶을 유지하는데 기여하고자 한다.