• 제목/요약/키워드: Forced-convection

검색결과 297건 처리시간 0.021초

환형휜이 부착된 두 개의 원형관 배열에 대한 강제대류 열전달 (Forced Convection Heat Transfer for Two Circular Tube Arrays with Annular Fins)

  • 김승일;박상희
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.1093-1101
    • /
    • 2020
  • This study was carried out numerically to investigate the air flow and thermal performance around single and parallel fin-tube heat exchangers and the cooling performance of the fluid inside the heat exchangers. In this study, the air velocity(1~7m/s), the pitch of fin(4, 6.1, 8, 11.3, 18.3, 44mm) and the diameter of fin(31, 33, 35, 37, 39mm) were varied. The flow rate of the water at the fin-tube heat exchanger inlet is 89cc/min and the water temperature is 353K. The air temperature at the upstream region of the heat exchanger is 300K. flow rate of the water at the fin-tube heat exchanger inlet is 80cc/min and the water temperature is 353K. It was found that the air pressure drop around single and parallel fin-tube heat exchangers was highly dependent on the air velocity and the fin pitch, but was independent of the fin diameter. Also, it was shown that pressure drop increased more the parallel arrangements than in single heat exchanger. The temperature difference of water at the inlet and outlet of the heat exchanger depended on the air velocity, the fin pitch and the fin diameter, and it was found that the parallel arrangement method further reduced the temperature of water. It was shown that the Nusselt number increased as the Reynolds number and the fin pitch increased, and decreased as the fin diameter increased.

나선형 튜브 열교환 방식의 포화 상태 액체질소의 비등열전달 특성에 대한 실험적 연구 (Experimental Research of Characteristic of Pool Boiling Heat Transfer of Saturated Liquid Nitrogen with Helical Coil Type Heat Exchanger)

  • 서만수;이지성;김정한;강선일
    • 한국추진공학회지
    • /
    • 제24권3호
    • /
    • pp.59-70
    • /
    • 2020
  • 본 논문에서는 기존 적층형 배관의 총 열전달 계수 경험식을 활용할 때 발생하는 한계점을 해결하고자, 외부 총 열전달 계수의 강제 대류 열전달 계수 항을 독립적으로 도출하는 간소화된 모델링을 제안하고, 이를 극저온 환경의 실험 결과로 확인하였다. 액체 산소 냉각 나선형 열교환기가 액체 질소와 열교환하는 실험 장치를 구성하고 열교환기의 열전달량을 계측하여, 외부 총 열전달 계수를 도출하였다. 측정된 외부 총 열전달 계수가 모델링으로 예측 곡선과 일치함을 확인하였다.

고압수소 저장용기의 노즐 각도 및 길이/직경비에 따른 열적 특성 연구 (A Study on the Thermal Characteristics of High Pressure Hydrogen Storage Tank according to Nozzle Angle and Length/Diameter Ratio)

  • 윤정환;권준영;전경숙;오진식;오승준
    • 한국수소및신에너지학회논문집
    • /
    • 제34권5호
    • /
    • pp.431-438
    • /
    • 2023
  • Recently, study on hydrogen is being conducted due to environmental pollution and fossil fuel depletion. High-pressure gas hydrogen commonly used is applied to vehicle and tube trailers. In particular, high-pressure hydrogen storage tank for vehicles must comply with the guidelines stipulated in SAE J2601. There is a charging temperature limitation condition for the safety of the storage tank material. In this study, numerical analysis method were verified based on previous studies and the nozzle angle was changed for thermal management to analyze the increase in forced convection effect and energy uniformity due to the promotion of circulation flow. The previously applied high-pressure hydrogen storage tank has a length/diameter ratio of about 2.4 and was analyzed by comparing the length/diameter ratio with 8. As a result, the circulation flow of hydrogen flowing into the high-pressure hydrogen storage tank is promoted at a nozzle angle of 30° than the straight nozzle and accordingly, the effect of suppressing temperature rise by energy uniformity and forced convection was confirmed.

Theory and technology of growing striation-free crystals

  • Scheel, Hans J.
    • 한국결정성장학회지
    • /
    • 제14권4호
    • /
    • pp.174-186
    • /
    • 2004
  • Striations are growth-induced inhomogeneities which hamper the applications of solid-solution crystals and of doped crystals in numerous technologies. Thus the optimized performance of solid solutions often can not be exploited. The inhomogeneity problem can be solved in specific cases by achieving a distribution coefficient one in growth from melts and from solutions. Macrostep-induced striations can be suppressed by controlling the growth mode, by achieving growth on facets thereby preventing step bunching. Thermal striations are commonly assumed to be caused by convective instabilities so that reduced convection by microgravity or by damping magnetic fields was and is widely attempted to reduce such inhomogeneities. Here it will be shown that temperature fluctuations at the growth interface cause striations, and that hydrodynamic fluctuations in a quasi-isothermal growth system do not cause striations. The theoretically derived conditions were experimentally established and allowed the growth of striation-free crystals of $KTa_{1-x}Nb_xO_3$"KTN" solid solutions. Hydrodynamic variations from the accelerated crucible rotation technique ACRT did not cause striations as long as the temperature was controlled within $0.03^{\circ}$ at $1200^{\circ}C$ growth temperature. Alternative approaches to solve or reduce the segregation and striation problems in growth from melts and from solutions are discussed as well.

PIV 유동 계측을 통한 천장형 실내기의 최적 제어 설계 (Optimal Flow Control of Ceiling Type Indoor Unit by PIV Measurements)

  • 성재용;안광협;이기섭;최호선;이인섭
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1042-1050
    • /
    • 2003
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated to determine the design parameters for the optimal flow control. The flow was measured by a PIV(particle image velocimetry) system and an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number. This similarity is generally used in cases where the forced convection has similar magnitude of the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, experimental results show that 30$^{\circ}$is an optimal angle to avoid re-suction flows without significant increase in flow noise. Temperature distribution measured in the environmental chamber ensures the increased thermal comfort when compared to the case, 60$^{\circ}$angle. At the optimal angle, applying open/close control gives rise to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for thermal comfort.

원형 실린더 주위의 전도-대류 열전달 (Wall Heat Conduction and Convection Heat Transfer from a Cylinder in Cross Flow)

  • 이상봉;이억수;김시영
    • 한국해양공학회지
    • /
    • 제15권3호
    • /
    • pp.1-8
    • /
    • 2001
  • With uniform heat generation within the wall of the cylinder placed in a cross flow, heat flows by conduction in the circumferential direction due to the asymmetric nature of the fluid flow around the perimeter of the cylinder. The circumferential heat flow affects the wall temperature distribution to such an extent that in some cases significantly different results may be obtained for geometrically similar surfaces. In the present investigation, the effects of circumferential wall heat conduction on local convective heat transfer is investigated for the case of forced convection around horizontal cylinder in cross flow of air. Two-dimensional temperature distribution $T_w$/(${\gamma}$,${\theta}$) is presented through the numerical analysis. The one-dimensional and two-dimensional solutions are in good agreement with experimental results of local heat transfer coefficients.

  • PDF

진공 배기 및 초음파 접합 복합기 진동자 냉각에 관한 연구 (A Study on Cooling of Piezoelectric Element of Multifunction Equipment for Vacuum Exhaust and Ultrasonic Joining)

  • 박상준;이영림
    • 한국산학기술학회논문지
    • /
    • 제13권4호
    • /
    • pp.1511-1517
    • /
    • 2012
  • 진공유리 배기공정을 위해 진공챔버나 진공튜브를 이용하는데 챔버 혹은 튜브 내부 전체를 진공으로 만들기 위한 시간과 경비가 과도하게 요구된다. 이러한 문제점을 해결하기 위해 상압에서 진공배기 및 초음파 접합이 동시에 가능한 복합기를 개발하고자 하였는데, 이 경우 진동자인 피에조 온도가 과도하게 상승하여 복합기의 냉각을 최적화할 필요성이 대두되었다. 따라서, 본 연구에서는 수치해석 및 실험을 통해 자연대류 및 강제대류 냉각방식의 효과를 규명하였고 이를 통해 진공 배기 및 초음파 접합 복합기의 냉각 성능을 최적화하였다.

HALE 무인기의 태양전지 열특성에 관한 해석적 연구 (A Numerical Study On Thermal Characteristics of HALE UAV Solar Arrays)

  • 송지한;남윤광
    • 한국추진공학회지
    • /
    • 제21권5호
    • /
    • pp.29-36
    • /
    • 2017
  • 본 연구에서는 수치해석을 통해 장기체공 무인기(HALE UAV)에 사용되는 태양전지에 대해 유동 및 열전달 해석을 수행하였다. 무인기가 운용되는 성층권에서는 강한 태양복사에너지가 유입되며, 자연대류에 의한 열전달이 감소하고 주위 유동에 의한 강제대류의 지배를 받는다. 이러한 환경에서의 태양전지 온도범위를 예측하기 위해 주익에 부착되어 있는 태양전지모듈을 대상으로 복합열전달 해석을 수행하였으며, 성층권 환경에서 시간에 따른 태양복사에너지, 비행속도, 밀도, 온도 등의 외기환경이 태양전지의 온도분포와 열전달 특성에 미치는 영향을 분석하였다.

천장형 실내기의 기류 가시화를 통한 최적 제어 설계 (Design of Optimal Vane Control for Ceiling Type Indoor Unit by PIV measurements)

  • 성재용;안광엽;이기섭;최호선;박승철;이인섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.533-536
    • /
    • 2002
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated using a PIV(particle image velocimetry) system For the PIV measurements, an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number, which is generally used in case that the forced convection has the similar magnitude as the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, the experimental results show that it should be less than $30^{\circ}$ to avoid re-suction flows which decrease the performance of the air-conditioner. At the vane angle of $30^{\circ}$, applying open/close control gives nae to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for the thermal comfort.

  • PDF

히트 파이프를 이용한 다중 LED 패키지의 방열 성능 연구 (Study on Thermal Performance of Multiple LED Packages with Heat Pipes)

  • 황순호;이영림
    • 대한기계학회논문집B
    • /
    • 제35권6호
    • /
    • pp.569-575
    • /
    • 2011
  • LED 조명기기의 경우 칩의 고밀도 발열로 인한 심각한 수명감소 및 광효율 저하, 색온도 변이의 문제점 등이 야기되므로 이를 해결하기 위해 주로 LED 패키지나 방열케이스를 최적화하는 연구가 이루어져 왔다. 최근들어 고출력 자동차 헤드램프나 가로등도 LED로 대체되어 가고 있는데 자연대류식 방열로는 그다지 효과적이지 않다. 따라서 본 연구에서는 고출력 조명기기 방열 성능 최적화에 강제대류를 이용한 히트파이프 사용의 타당성을 알아보았다. 또한, 팬의 수명이 LED 수명에 비해 일반적으로 낮으므로 이를 보완하기 위한 최적화된 팬의 정지-작동 제어가 팬 수명 증가에 미치는 영향도 고찰하였다.