Initial Pole Position Estimation Algorithm of a Z-Axis PMLSM (Z축 선형 영구자석 동기전동기의 초기 자극위치 추정 알고리즘)

  • Lee, Jin-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.41-45
    • /
    • 2008
  • This paper deals with the estimation method on the initial pole position of a z-axis permanent magnet linear synchronous motor(PMLSM) without magnetic pole sensors such as Hall sensors. The proposed method takes account of the gravitational force at z-axis and also the load conditions. The algorithm consists of two steps. The first step is to approximately estimate the initial q-axis by monitoring the movements due to the test current at predefined different test q-axes. The second step is to estimate the real q-axis as accurately as possible by using the outputs corresponding to torques due to the test current at three different test q-axes in order to avoid the effect of load mass variations. Experimental results on the z-axis PMLSM show good estimation characteristics of the proposed method irrespective of load mass conditions.

Design of electromagnetic type transducer to drive round window with high efficiency (고효율 전자기형 정원창 구동 트랜스듀서의 설계)

  • Lee, Jang-Woo;Kim, Dong-Wook;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.449-455
    • /
    • 2010
  • Implantable middle ear hearing devices(IMEHDs) have being actively studied to overcome the problems of conventional hearing aids. Vibration transducer, an output devices of IMEHDs, is attached on the ossicular chain and transmits mechanical vibration to cochlea. This approach allows us to hear more clear sound because mechanical vibration is effective to transfer high frequency acoustics, but occurs some problems such as fatigue accumulation to ossicular chian and reduction of vibration displacement caused by mass loading effect. Recently, many studies for the round window stimulation are announced, because it does not cause such problems. It have been studied by older transducers designed for attaching on ossicular chain. In this paper, we proposed a new electromagnetic transducer which consists of two magnets, three coils and a vibration membrane. The magnet assembly, magnet coupled in opposite direction, were placed in the center of three coils, and the optimum length of each coil generating maximum vibrational force was calculated by finite element analysis(FEA). The transducer was implemented as the calculated length of each coil, and measured vibration displacement. From the results, it is verified the vibration displacement can be improved by optimizing the length of coils.

Evaluation of Remote Handling Performance with the Polarized Stereo Monitoring System (편광방식 스테레오 모니터링 시스템의 원격조작성 평가)

  • Lee, Yong-Bum;Lee, Nam-Ho;Park, Soon-Yong;Lee, Jong-Min;Jin, Sung-Il
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.55-62
    • /
    • 1996
  • This paper describes development of Polarized Stereo Monitoring System (KAERI-PSM) and compares the remote handling performance of KAERI-PSM with that of other monitoring systems, electric shutter type stereo monitoring system and general TV monitoring system. Remote handling performance is evaluated by total time and error number on remote operating experiments. Four kinds of remote handling experiments are carried out through 1) directly 2) general TV 3) electric shutter type monitor, and 4) KAERI-PSM. In these experiments six employees are participated and PUMA robot with force-torque reflectional joystic is used. The result of experiments show that camera angle against object is significant factor in monitoring and stereo monitoring system give more performance benifits in terms of accuracy and speed of remote handling operation than general TV monitoring system. In comparision of the polarized and electric shutter type stereo monitoring system, both have similar accuracy and speed for remote handling operation, but the former is superior in image quality and stability of the performance.

  • PDF

Fabrication, Performance Evaluation of Components of Planar Type MEMS Solid Propellant Thruster (평판형 MEMS 고체 추진제 추력기 요소 제작 및 성능 평가)

  • Park, Jong-Ik;Kwon, Se-Jjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.6
    • /
    • pp.581-586
    • /
    • 2008
  • The MEMS solid propellant thrusters have very low thrust level for applying to the propulsion system of micro/nano satellites or the side jet thruster of smart bombs. In this research, the fabrication possibility of planar type MEMS solid propellant thrusters that have enlarged burning surface area was examined and the safety of the structure of thruster during the firing test was confirmed. The performance of a micro igniter which is the key component of the MEMS solid propellant thruster was estimated by the ANSYS Icepak and evaluated by the experiment. Finally, the thrust was measured by the micro force sensor. The levels of thrust were 300, 600 mN in the case of K=15, 20.

A Development of Rehabilitation System for Upper Limb Using Robot Manipulator (로봇을 이용한 상지 재활 시스템에 관한 연구)

  • 원주연;심형준;한창수
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.309-318
    • /
    • 2003
  • In this paper a 6 degree-of-freedom robot was studied for medical purpose. In the past the robot used for industry field was utilized for medical robot but in these days the robot used for rehabilitation. welfare, and service. This system was Proposed for a stroke patient or a patient who can not use one arm. A master-slave system was constructed to exercise either paralysis or abnormal arm using normal arms movement. Study on the human body motion result was applied to calculate a movement range of humans elbow and shoulder. In addition, a force-torque sensor is applied to estimate the rehabilitation extent of the patient in the slave robot. Therefore, the stability of the rehabilitation robot could be improved. By using the rehabilitation robot, the Patient could exercise by himself without any assistance In conclusion. the proposed system and control algorithm were verified by computer simulation and system experiment.

A Study on the Correlation Improvement between FEA and Test for a Pedestrian Lower Legform Impact (보행자보호 Lower Legform 충격의 해석 대 시험 상관성 개선에 관한 연구)

  • Park, Dong-Kyou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1515-1522
    • /
    • 2011
  • This paper proposed the finite element analysis technique for improving the correleration accuracy between FEA and test on a pedestrian lower legform impact. Europe has been evaluating the bumper pedestrian impact by Euro-NCAP, and it will also be applied in a domestic area by K-NCAP in 2013. By using the compression test result of bending resisting stiffener, a pedestrian bumper modeling guide was presented by analayzing the force-displacement curve of stiffener. And by using the sensor measurement results in car pedestrian test, pedestrian impact behavior was analyzed between test and finite element analysis result. Finally, the finite element analysis guide for a pedestrian bumper impact was presented to improve the correleration accuracy.

Verification of Long-distance Vision-based Displacement Measurement System (장거리 영상기반 변위계측 시스템 검증)

  • Kim, Hong-Jin;Heo, Suk-Jae;Shin, Seung-Hoon
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.47-54
    • /
    • 2018
  • The purpose of this study is to verify the long - range measurement performance for practical field application of VDMS. The reliability of the VDMS was verified by comparison with the existing monitoring sensor, GPS, Accelerometer and LDS. It showed the ability to accurately measure the dynamic displacement by tracking a motion of free vibration of target. And using the PSD function of measured data, the results in the frequency domain were also analyzed. We judged that VDMS is able to identify the higher system mode and has sufficient reliability. Based on the reliability verification, we conducted tests for long-distance applicability for actual application of VDMS. The distance from the stationary target model structure was increased by 50m interval, and the maximum distance was set to 400m. From the distance of 150m, the image obtained by the commercial camcorder has an error in the analysis, so the measured displacement comparison was performed between the LDS and the refractor telescope measurement results. In the measurement results of the displacement area of VDMS, the data validity was deteriorated due to the data shift by the external force and the quality degradation of the enlarged image. However, even under the condition that the effectiveness of the displacement measurement data of VDMS is low, the first mode characteristic included in the free vibration of the object is clearly measured. If the influence from the external environment is controlled and stable data is collected, It is judged that reliability of long-distance VDMS can be secured.

Analysis and Training Contents of Body Balance Ability using Range of Motion of Lumbar Spine and Center of Body Pressure (요추 관절가동범위와 신체압력중심을 이용한 신체균형능력 분석 및 훈련 콘텐츠)

  • Goo, Sejin;Kim, Dong-Yeon;Shin, Sung-Wook;Chung, Sung-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.279-287
    • /
    • 2019
  • In this paper, we attempted to analyze the balance ability of the body by measuring changes in body motion and plantar pressure distribution. So we developed a program that can measure and analyze range of motion and center of body pressure using inertial measurement unit(IMU) and FSR(Force Sensing Resistor) sensor, we also produced a contents that can help improve the balance ability. The quantitative values of range of motion and center of body pressure measured by this program are visualized in real time so that the user can easily recognize the results. In addition, the contents were designed to be adjusted according to the direction of improving the balance ability by adjusting the difficulty level based on the measured balance information. This can be achieved by increasing the concentration and participation will by using visual feedback method that proceeds while watching moving objects according to the user's motion.

Hysteresis Behavior in Electric Resistance-hydrogen Concentration of Pd Thin Films (Pd 박막의 전기저항-수소농도 이력현상)

  • Lee, Eunsongyi;Lee, Jun Min;Jeon, Kye Jin;Lee, Wooyoung
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.6
    • /
    • pp.372-377
    • /
    • 2009
  • We report on hysteresis behavior in the electrical resistance-hydrogen concentration of Pd thin films. The variation of the electrical resistance has been investigated during the process of absorption and desorption of hydrogen gas ($H_{2}$) as a function of thickness of Pd thin films. The hysteresis behavior in the electrical resistance with $H_{2}$ concentration was found for Pd thin films and consists of $\alpha$ phase, ${\alpha}+{\beta}$ phase, and $\beta$ phase regions. The sensitivity of Pd thin films with $H_{2}$ concentration was found to follow Sieverts' law in the $\alpha$ phase region. However, the sensitivity was observed to increase abruptly with $H_{2}$ concentration in the ${\alpha}+{\beta}$ phase co-exist region. This is because Pd-H interaction is stronger in the $\beta$ phase than in the $\alpha$ phase and needs a higher concentration gradient as a driving force to desorb. The formation of the $\beta$ phase also was observed to cause the structural change because of the lattice expansion during absorption. The hysteresis height and the trace of structural change were affected by the thickness of the Pd film. As the film becomes thinner, the hysteresis height becomes lower and the amount of delamination on the surface becomes smaller. For films thinner than 20 nm in thickness, the delamination was not found but electrical resistance hysteresis was still observed.

Effects of Vibrotactile Bio-Feedback Providing Pressure Information in Real Time on Static Balance and Weight Bearing Rate in Chronic Stroke Patients - Pilot Study (실시간 압력정보 제공 진동 촉각 피드백이 만성 뇌졸중 환자의 정적균형능력과 체중 지지율에 미치는 영향 - 예비실험연구)

  • Kil, Ki-Su;Kim, Ho;Shin, Won-Seob
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.1
    • /
    • pp.41-48
    • /
    • 2021
  • Purpose : The purpose of this study is to find out if it helps to improve static balance ability and weight bearing rate for chronic stroke patients with poor balance in clinical intervention through a method of correcting movement errors while performing a task by vibrotactile bio-feedback providing pressure information. Methods : Fifteen chronic stroke patients (12 male and 3 female) were participated in this study. To examine the effects of vibrotactile bio-feedback and general standing without bio-feedback on static balance ability and weight distribution symmetric index in all subjects randomized with R Studio. The static balance ability and weight distribution symmetric index of the participants was evaluated using a force plate. A paired t-test was used for comparison of each conditions. Statistical significance was set at α=0.05. Results : The comparisons of static balance ability and weight distribution symmetric index in chronic stroke patients after two different condition are as follows. In the static balance ability and weight distribution symmetric index, the vibrotactile feedback providing pressure information showed a significant difference compared to none feedback (p<.001). Conclusion : The vibrotactile bio-feedback providing pressure information in real time can support an improve in static balance ability, uniform weight bearing rehabilitation in chronic stroke patients. In the future, it is hoped that a follow-up study that provides a better direction of intervention compared to various feedback interventions commonly used in clinical practice.