• Title/Summary/Keyword: Force Display System

Search Result 139, Processing Time 0.025 seconds

Modeling and Control of a Four Mount Active Micro-vibration Isolation System

  • Banik, Rahul;Gweon, Dae-Gab;Hong, Dong-Pyo
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.10a
    • /
    • pp.150-153
    • /
    • 2006
  • Micro vibration isolation, typically originated from ground, is always a prime concern for the nano-measurement instruments such as Atomic Force Microscopes. A four mount active vibration isolation system is proposed in this paper. Modeling and control of such a four mount system as analyzed. Combined active-passive isolation principle is used for vibration isolation by mounting the instrument on a passively damped isolation system made of Elastomer along with the active stage in parallel that consists of very soft actuation system, the Voice Coil Motor. The active stage works in combination with the passive stage for working as a very low frequency vibration attenuator.

  • PDF

Study on Flow Analysis in Glass Panel Vacuum Lift System (Glass 패널 진공흡착시스템의 유동해석 연구)

  • Kim, Dong-Kyun;Yoon, Cheon-Seog
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.11
    • /
    • pp.886-893
    • /
    • 2009
  • To develop glass panel vacuum lift system for the post process in module line of FPD(Flat panel display) such as LCD and PDP, new vacuum adsorption parts of this system are proposed. These parts are composed of variable geometry configurations utilizing ceramic porous medium for variable size of glass panels. In order to design this device, detail understanding of flow phenomena in the flow path of vacuum adsorption system is essential. Thus, CFD analysis and designs are performed for several configurations in terms of pressure drop and balancing force at the adsorption side. From the result, new configuration is recommended for optimum design and manufacturing purpose.

Collision Detection and Response Calculation for 3-D Computer Animation (3차원 컴퓨터 애니메이션을 위한 충돌 검색 및 반응 계산)

  • 김현준;경종민
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.3
    • /
    • pp.130-138
    • /
    • 1993
  • A mechanism for collision detection in general animation system is necessary to prevent the interpenetration among multiple objects. On the other hand, a dynamic simulation system which is a part of animation system simulates realistic motions using dynamics after the collision, which is called collision response. In this paper, a method for reducing the CPU time for collision detection by removing redundant calculations and object sorting is proposed. A dynamic simulation system including collision detection and response function was implemented to demonstrate the proposed methods, where the input data as elasticity, friction, gravity, object shape, external force and external torque are given by the user. The system simulates motions of multiple objects using dynamics, and generates the wireframe display.

  • PDF

Flow Analysis around the Roller Conveyor in a Clean Room (클린룸 내 롤러 컨베이어 운송장치 주위의 유동해석)

  • Jeon, Hyun-Joo;Park, Chan-Woo;Im, Ik-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1507-1512
    • /
    • 2009
  • Flow field in a roller conveyor system, induced from the movement of a cassette in which glasses for flat panel display are loaded, is numerically studied in this paper. Contamination on the glass surface by dust particles produced from mechanical friction between roller and cassette is predicted from the analysis results of flow fields. Results show that a large swirl flow is formed under the moving cassette with constant speed. This swirl flow is confined only under the cassette because two main streams from the backward and the fan filter unit on the top ceiling are sufficiently strong. Therefore, it can be said that possibility of the contamination by the particles originated from the friction is relatively low. It is also revealed that flow direction between glass plates is changed according to the speed of the cassette movement due to the shear force of glass plates.

  • PDF

Design of Continuous Passive Motion Medical Device System with Range of Motion Measurement Function (관절가동범위 측정 기능을 갖는 연속수동운동 의료기기 시스템 설계)

  • Kang Won Lee;Min Soo Park;Do Woo Yu;Oh Yang;Chang Ho Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.87-92
    • /
    • 2023
  • As the elderly population increases, the number of patients with various joint diseases, including degenerative arthritis, is steadily increasing. CPM medical devices are needed to effectively treat degenerative arthritis that is common in the elderly population. Domestic CPM medical devices have limited functions and are highly dependent on imports for expensive imported medical devices. To solve this problem, we designed a ROM measurement function using a current sensor that is not present in existing composite joint CPM medical devices. The algorithm was designed using the fact that the force caused by joint stiffness greatly increases the current flowing through the DC motor. In addition, the need for digital healthcare in the medical field is gradually expanding as the proportion of chronically ill patients increases due to the spread of the non-face-to-face economy due to COVID-19 and the aging population. Therefore, this paper aims to improve the performance of CPM medical devices by allowing real-time confirmation of rehabilitation exercise information and operation range measurement results in accordance with digital healthcare trends through a Bluetooth application developed as an Android studio.

  • PDF

Design of an Electromagnetically-driven Micromirror Through the Coupled Physics Analyses (복합장 해석에 의한 전자력 구동방식의 마이크로미러 설계)

  • Han, Seung-Oh;Kim, Byoung-Min;Pak, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.380-384
    • /
    • 2010
  • A micromirror for a laser display system actuated by the electromagnetic force induced by the surface coil and the permanent magnet was designed and analyzed through the coupled physics analyses incorporating the electromagnetics, mechanics, and electrothermal analysis because the mechanical rotation of the micromirror is driven by the electromagnetic driving force. The proposed micromirror has two torsion beams to sustain the mirror plate which has surface coils on the top and the two permanent magnets exists on both sides of the micromirror for an external magnetic field source. The designed micromirror has the resonant frequency of 3.82kHz. When the magnetic field of the permanent magnet is 0.4T, the coil has 4 turns, and the current density of coil is 3.6A/$mm^2$, the estimated z axis displacement of the mirror plate edge is 0.23mm which corresponds to the rotation angle of $14.2^{\circ}$. When considering the joule heating in the current-carrying coil, the maximum temperature of the mirror plate is obtained as 300.045K, which induces the negligible changes in the rotation angle and the resistance of the coil.

Measurement of postural instability before and after experiencing a VR system by using a force platform (힘판을 이용한 가상현실 체험 전후 신체동요의 측정)

  • 박재희;김영윤;김은남;김현택;고희동
    • Science of Emotion and Sensibility
    • /
    • v.5 no.4
    • /
    • pp.45-49
    • /
    • 2002
  • Recently, virtual environment systems are used in various application fields such as industry, medicine, and training and education. However, the negative effect, cybersickness including nausea, visual fatigue, and disorientation, could be happened while using VR systems. It prevents VR system from spreading much more. To control the cybersickness, first of all, the objective measurement method should be established. As one of alternative methods, the postural instability could be a measure of cybersickness. In this study, 45 participants' postural sway before and after experiencing a H driving simulator was measured by using a force platform. Especially, we examined if two factors, motion and feedback, could affect on the postural instability The results showed the postural instability slightly increased after experiencing the VR driving simulator. For the factors, the providing of motion synchronized to visual display showed statistical significant decrease in postural sway along lateral side. To check the effectiveness of postural instability as a cybersickness measure, further studies are needed.

  • PDF

Vision-Based Haptic Interaction Method for Telemanipulation: Macro and Micro Applications (원격조작을 위한 영상정보 기반의 햅틱인터렉션 방법: 매크로 및 마이크로 시스템 응용)

  • Kim, Jung-Sik;Kim, Jung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1594-1599
    • /
    • 2008
  • Haptic rendering is a process that provides force feedback during interactions between a user and an object. This paper presents a haptic rendering technique for a telemanipulation system of deformable objects using image processing and physically based modeling techniques. The interaction forces between an instrument driven by a haptic device and a deformable object are inferred in real time based on a continuum mechanics model of the object, which consists of a boundary element model and ${\alpha}$ priori knowledge of the object's mechanical properties. Macro- and micro-scale experimental systems, equipped with a telemanipulation system and a commercial haptic display, were developed and tested using silicone (macro-scale) and zebrafish embryos (micro-scale). The experimental results showed the effectiveness of the algorithm in different scales: two experimental systems applied the same algorithm provided haptic feedback regardless of the system scale.

  • PDF

A Study on the Performance Improvement of PZT Actuator Controller for Metal Jet (메탈젯용 PZT 액츄에이터 제어기 성능향상에 관한 연구)

  • Yun, So-Nam;Jo, Jeong-Dae;Lee, Taek-Min
    • 연구논문집
    • /
    • s.33
    • /
    • pp.81-88
    • /
    • 2003
  • A metal jet printing system based on ink jet printing technique is one of the effective equipments for manufacturing elements of display devices, electrical devices, information processing systems, and so on. In order to develop an actuator of the metal jet printing system, bimorph type PZT actuator(length 25.2mm, width 7.2mm, thickness 0.5mm, shim thickness 0.2mm) and its controller(voltage range $\pm24v$, built-in fast recovery diode) were suggested and investigated. Performance tests and characteristic analysis, such as displacement, force, hysteresis and frequency, were carried out. The results show that the suggested actuator and controller are suitable for the metal jet printing system.

  • PDF

The Monitoring system for the measurement of the operating performance of a LIM which can be drive a new vehicle (신교통 차량 추진용 리니어모터의 운전성능측정 및 모니터링시스템 구축)

  • Jang, S.M.;Park, Y.T.;Seo, J.H.;Jeong, S.S.;Lee, S.H.;Ham, S.Y.;Park, C.I.;Jeong, R.G.;Lee, J.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.74-76
    • /
    • 1997
  • This paper describes the implementation for electrical quanties and mechanical quanties monitoring system of the LIM driven by a inverter. The monitoring system can be display the characteristics of it's quanties, such as voltage, current, power, power factor, frequency, apparent power, thrust, speed, position, normal force, on the real time.

  • PDF