• 제목/요약/키워드: Foot Sensor

검색결과 137건 처리시간 0.03초

뇌졸중 환자에서 지팡이 종류에 따른 지팡이와 양발의 체중지지에 미치는 영향 (The Effect of Changes in Walking Aids on Weight Bearing on the Cane and Foot in Stroke)

  • 정경심;정이정
    • The Journal of Korean Physical Therapy
    • /
    • 제24권2호
    • /
    • pp.113-117
    • /
    • 2012
  • Purpose: The purpose of this study was to analyze the weight bearing of the cane and foot for the different walking aids during walking. Methods: A total of 12 subjects (6 males, 6 female) with stroke were enrolled in the study. Foot sensor and an instrumented cane were integrated to analyze the vertical peak force on the foot and cane. Results: The vertical peak force applied on the quad cane gait resulted in a significantly higher rate, which was $10.60{\pm}6.48%$ of the body weight, when compared to that of mono cane gait which was $7.91{\pm}4.11%$. The results indicated significantly lower vertical peak force on the affected foot, without the help of a walking aid, as compared to that of walking with a cane (respectively, p<0.05). However, results showed that the differences in vertical peak force on the affected foot, between mono cane and quad cane, were not significant. Conclusion: In conclusion, the vertical peak forces were significantly greater, during a comparison between walking with a quad cane and walking with a mono cane. On the contrary, no significant difference in the vertical peak force on the affected foot between walking with quad cane and walking with a mono cane. Muscle activation pattern and walking pattern should be measured in future studies, to study the differences between walking with various walking aids in the lower and higher functioning hemiparetic subjects, as its use may mask underlying gait impairment.

Development of Intelligent Powered Gait Orthosis for Paraplegic

  • Kang, Sung-Jae;Ryu, Jei-Cheong;Moon, In-Hyuk;Kim, Kyung-Hoon;Mun, Mu-Seung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1272-1277
    • /
    • 2005
  • In this study, we wolud be developed the fuzzy controlled PGO that controlled the flexion and the extension of each PGO's joint using the bio-signal and FSR sensor. The PGO driving system is to couple the right and left sides of the orthosis by specially designed hip joints and pelvic section. This driving system consists of the orthosis, sensor, control system. An air supply system of muscle is composed of an air compressor, 2-way solenoid valve(MAC, USA), accumulator, pressure sensor. Role of this system provide air muscle with the compressed air at hip joint constantly. According to output signal of EMG sensor and foot sensor, air muscles and assists the flexion of hip joint during PGO gait.

  • PDF

센서 네트워크를 이용한 2족 보행 로봇의 워킹 방법에 관한 연구 (A study of Human robot Walking Method Using Zigbee Sensor Network)

  • 신대섭;이형철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.375-377
    • /
    • 2009
  • This paper researched the algorithm of robot's walking and action on the basis of robot studied and made at our laboratory and studied how to efficiently control the robot joints by developing wireless Digital Servo Motor using Zigbee Sensor Network Module which is using at wide part recently. I realized the stable walking by adopt Press Sensor at the bottom of robot foot to get stability of walking. Also I let the algorithm calculate the robot movement to make the joint motion and monitored the robot walk to its motion. At this Paper, I studied the method organizing the motion by the each robot walking and measuring the torque applying to the joint. And I also knew that it is possible to make its control and construct hardware more conveniently than them of the existing studied and controling 2Legs Walking Robot by applying it at walking robot and developing wireless servo motor by Zirbee Sensor Network.

  • PDF

자폐성 장애 아동의 시공간 및 압력분포 변인을 통한 장애물보행 분석 (Analysis of Obstacle Gait Using Spatio-Temporal and Foot Pressure Variables in Children with Autism)

  • 김미영;최범권;임비오
    • 한국운동역학회지
    • /
    • 제21권4호
    • /
    • pp.459-466
    • /
    • 2011
  • The purpose of this study was to analyze of obstacle gait using spatio-temporal and foot pressure variables in children with autism. Fifteen children with autism and fifteen age-matched controls participated in the study. Spatio-temporal and foot pressure variables was investigated using GAITRite pressure sensor system. Each footprint was divided into 12 equal trapezoids and after that the hindfoot, midfoot and forefoot analysis was developed. Independent t-test was applied to compare the gait variables between the groups. The results showed that the autism group were significantly decreased in velocity, cadence, cycle and swing time compared to the control group. The autism group were significantly increased in step width and toe out angle compared to the control group. The autism group were significantly increased at midfoot and forefoot of lateral part of footprint and forefoot of medial part of footprint in the peak time compared to the control group. The autism group were significantly increased at midfoot and hindfoot in $P^*t$, at midfoot in active area, and at hindfoot in peak pressure compared to the control group. In conclusion, the children with autism showed abnormal obstacle gait characteristics due to muscle hypotonia, muscle rigidity, akinesia, bradykinesia and postural control impairments.

RGB-D 이미지에서 인체 영역 검출을 위한 프레임워크 (A Framework for Human Body Parts Detection in RGB-D Image)

  • 홍성진;김명규
    • 한국멀티미디어학회논문지
    • /
    • 제19권12호
    • /
    • pp.1927-1935
    • /
    • 2016
  • This paper propose a framework for human body parts in RGB-D image. We conduct tasks of obtaining person area, finding candidate areas and local detection in order to detect hand, foot and head which have features of long accumulative geodesic distance. A person area is obtained with background subtraction and noise removal by using depth image which is robust to illumination change. Finding candidate areas performs construction of graph model which allows us to measure accumulative geodesic distance for the candidates. Instead of raw depth map, our approach constructs graph model with segmented regions by quadtree structure to improve searching time for the candidates. Local detection uses HOG based SVM for each parts, and head is detected for the first time. To minimize false detections for hand and foot parts, the candidates are classified with upper or lower body using the head position and properties of geodesic distance. Then, detect hand and foot with the local detectors. We evaluate our algorithm with datasets collected Kinect v2 sensor, and our approach shows good performance for head, hand and foot detection.

Temple and Maternity Ward Security using FPRS

  • Ambeth Kumar, V.D.;Ramakrishnan, M.;Jagadeesh Kannan, R.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.633-637
    • /
    • 2013
  • A wide range of applications for Foot Print Recognition System is discussed in this paper. The whole concept works under the principle that foot print is a parameter associated with biometrics that is very common as well as distinct. Its foremost application is at the government hospitals in the under developed and third world nations where there aren't the best of facilities. This system can be applied in the maternity ward of the hospitals for the identification or differentiation of the infants. Till date there has been no specialized system adopted for this purpose. The Foot Print Recognition System will overcome all the defects of any biometrics when applied here. Since the child will be very delicate for an iris scan and it will not be able to open its eyes wide or to correctly place its finger print on the sensor since the hands of a new born infant will be closed for a while. The Foot Print Recognition system can also be implemented in temples where there are cases of theft often reported. This can be used to grant access to the karpagraham of the deity by authorized users alone. These 2 applications of FPRS are discussed in this paper.

전자-기계식 클러치를 이용한 장하지 보조기용 무릎관절 자동 제어 장치의 개발 (Development of the Automatic Knee Joint Control System for a Knee-Ankle-Foot Orthosis Using an Electromechanical Clutch)

  • 이기원;강성재;김영호;조강희
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권4호
    • /
    • pp.359-368
    • /
    • 2001
  • A new knee-ankle-foot-orthosis(KAFO) which uses an automatically-controlled electromechanical wrap spring clutch for the knee joint was developed in the present study. It was found that the output voltage from the foot switches of the developed KAFO was proportionally increased with respect to the applied load. The output voltage from the infrared sensor also decreased as the knee flexion angle increased. The knee joint system for the new KAFO weighs only 780g lighter than any other commercially available developed system. In addition, the solenoid reduces the reaction time for the automatic control of the knee joint. The static torque of the clutch was measured for three persons, and it satisfied the normal knee extension moment during the pre-swing. Three-dimensional gait analyses for three different gait patterns (normal gait, locked-knee gait, controlled-knee gait) from five normal subjects were conducted. Controlled-knee gait showed the maximum knee flexion angle of 40.56$\pm9.55^{\circ}$ and the maximum knee flexion moment of 0.20$\pm$0.07Nm/kg at similar periods in the normal gait. Our KAFO system satisfies both stability during stance phase and free knee flexion during the swing phase at the proper period during the gait cycle. Therefore, our KAFO system would be very useful in various low extremity orthotic applications.

  • PDF

접촉성 손-위치 반응(Contactual Hand-Orientating Response)이 만성 뇌졸중환자의 일어서기 동작에 미치는 영향 (The Effects of Contact Hand-Orientation Response(CHOR) During Sit-to-stand(STS) in People with Stroke)

  • 서태화;양시은;이홍균
    • 신경치료
    • /
    • 제22권3호
    • /
    • pp.31-36
    • /
    • 2018
  • Purpose The purpose of this study was to investigate the effects of contact handorientation response(CHOR) during sit-to-stand(STS) in people with stroke. Methods The subjects of the study were Thirty hemiplegia participated (Rt. hemiplegia/Lt. hemiplegia: 15/15, mean age: $65.82{\pm}8.53$) in this study. The analysis of muscles activation (rectus femoris, biceps femoris, tibialis anterior, gastrocnemius) distribution was conducted by the EMG, and the analysis of foot pressure distribution was conducted by the resistive pressure sensor. Hemiplegic stroke patients were instructed to perform STS three times with the non-affected side hand and affected side hand on the table. Results There was a significant positive correlation between rectus femoris, tibialis anterior muscle activation and affected side hand contact during STS(p<0.05). The STS correlated with the foot pressure in the affected side hand contact(p<0.05). Conclusion AS a result, CHOR during STS is related to muscle activation and the characteristics of foot pressure. This information was observed in the affected side hand contact on the table, suggestion that rehabilitation programs should be implemented.

충격흡수 및 통기기능 인솔을 적용한 개발 전투화의 족저압력 및 온도변화 연구 (A Study on the Foot Plantar Pressure and Temperature changes of the Developed Combat boots with Functional Impact Absorption and Ventilation Insole)

  • 한기훈;이중숙;배강호;신진형;정상옥
    • 한국응용과학기술학회지
    • /
    • 제35권1호
    • /
    • pp.89-98
    • /
    • 2018
  • 본 연구의 목적은 충격흡수 및 통기기능 인솔을 적용한 개발 전투화의 족저압력 및 온도변화를 연구하는데 있다. 남성 피험자 11명(age: $21.8{\pm}2.2yrs$, height: $174.3{\pm}3.6cm$, weight: $71.6{\pm}8.6kg$, foot length: $261.0{\pm}1.0mm$)을 대상으로 총 3종류 전투화의 족저압력 및 온도 변화를 비교하였다: 전투화 A(보급형 일반 전투화), 전투화 B(통기구가 적용된 개발 전투화), 전투화 C(전투화 B에 통기기능 및 충격흡수용 인솔 적용). 족저압력 측정을 위해 Pedar-X를 사용하였고, 전투화의 내부온도는 휴대용 써미스터의 온도센서를 사용하였다. 전투화의 종류별 족저압력 및 온도 변화결과를 비교하기 위해 일원변량분석(one-way ANOVA)을 실시한 결과, 첫째, 족저압력 변인에서, 기능성 인솔을 적용한 전투화 C가 전투화 A보다 오른발/왼발 후족부의 최대족저압력에서 통계적으로 유의하게 낮았으며, 전투화 C가 전투화 B보다 왼발 후족부의 평균족저압력에서 통계적으로 유의하게 낮은 압력을 나타내었다. 둘째, 내부온도에서 보행시작 후 40분경과 시점부터 개발 전투화인 B, C가 일반 전투화인 A보다 낮은 내부 온도를 보였다.

한복 버선에 관한 연구 -버선 원형의 비교를 중심으로- (A Study on Boesun -On the Comparison of the Basic Patterns of Boesun-)

  • 문명옥;김야지
    • 한국의류학회지
    • /
    • 제9권2호
    • /
    • pp.45-55
    • /
    • 1985
  • The main purpose of this study is to investigate the suitability of Boesun (the Korean Socks) to the foot. In order to find the problem of Boesun, I made up the questionnaire. The suitabltity of Boesun to the foot was experimented by 'the replica method', 'the fuse method' and 'the deform painting method'. The pressure of Boesun to the foot was measured by utilizing a human sensitivity as a sensor. The results were as follows. 1. In the questionnaire, the fore part of Boesum was uncomfortable by the pressure. 2. The surface area of Boesun was generally smaller than the surface area of the foot, but the ratio of two surface area related closely to the individual. 3. At the cross-sections from No. 1 to No. 10, the breadth of the worn Boesun was smaller than the breadth of the foot. Because of the smaller breadth of the worn Boesun, the foot was get the pressure at the fore part of Boesun. This result accorded with the result of the questionnaire. 4. The location of the deformation by 'deform painting method' was almost the fore part of Boesun. 5. The pressure of Kwon's Boesun was 2.57$\~$2.99kg, the pressure of Kim's Boesun was 1.31$\~$1.74 kg and the pressure of Lee's Boesun was 3.42$\~$3.88kg. Compared with the distribution chart of the pressure, Kwon's Boesun was involved the back part of 'slightly pressured' and the fore part of 'pressured', Kim's Boesun was involved the fore part of 'slightly pressured' and Lee's Boesun was involved the middle part of 'pressured'.

  • PDF