• 제목/요약/키워드: Flux of reverse osmosis membrane

검색결과 120건 처리시간 0.022초

역삼투막을 이용한 음식폐기물 액비의 농축 (Accumulation of Food Wastes Liquid Fertilizer using Reverse Osmosis Membrane System)

  • 차기철;황명구;이명규;태민호
    • 한국물환경학회지
    • /
    • 제18권2호
    • /
    • pp.159-168
    • /
    • 2002
  • A lab-scale Reverse Osmosis(RO) membrane reactor was installed to investigate the membrane permeability, characteristics of membrane fouling at each conditions, and performance of elimination at different trans-membrane pressure(TMP) in the liquid fertilizer accumulated system. Experimental setup was divided to three different TMP conditions. As a result of experiment, permeability of RO membrane was proportional to the increase of TMP and temperature. After experiment was completed, two types chemical cleaning(remove the organic foulant and inorganic foulant) was done, and recover rate of permeability was each 99.8, 99.7 and 99.7%, respectively. From this experimental data, membrane fouling could be determined that the most of it was recoverable in this system, and major reason of fouling was concentration polarization. Elimination rate of solute substance in the liquid fertilizer indicated very stable(above 99%), except ammonia nitrogen, and the most stable elimination rate was investigated at the highest TMP condition (Run 3).

역삼투막을 이용한 해수담수화 플랜트에서 전처리 공정 기술 (An Overview of the Pretreatment Processes in Seawater Desalination Plants using Reverse Osmosis Membranes)

  • 안창훈;이원일;윤제용
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.811-823
    • /
    • 2009
  • Seawater desalination process using a reverse osmosis (RO) membrane has been considered as one of the most promising technologies in solving the water scarcity problems in many arid regions around the world. To protect RO membrane in the process, a thorough understanding of the pretreatment process is particularly needed. Seawater organic matters (SWOMs) may form a gel layer on the membrane surface, which will increase a concentration polarization. As the SWOMs can be utilized as a substrate, membrane biofouling will be progressed on the RO membrane surface, resulting in the flux decline and increase of trans-membrane pressure drop and salt passage. In the middle of disinfection, an optimal chlorine dosage and neutralizer (sodium bisulfite, SBS) should be practiced to prevent oxidizing the surface of RO membranes. Additional fundamental research including novel non-susceptible biofouling membranes would be necessary to provide a guide line for the proper pretreatment process.

Pilot scale membrane separation of plating wastewater by nanofiltration and reverse osmosis

  • Jung, Jaehyun;Shin, Bora;Lee, Jae Woo;Park, Ki Young;Won, Seyeon;Cho, Jinwoo
    • Membrane and Water Treatment
    • /
    • 제10권3호
    • /
    • pp.239-244
    • /
    • 2019
  • Plating wastewater containing various heavy metals can be produced by several industries. Specifically, we focused on the removal of copper (Cu2+) and nickel (Ni+) ions from the plating wastewater because all these ions are strictly regulated when discharged into watershed in Korea. The application of both nanofiltration (NF) and reverse osmosis (RO) technologies for the treatment of wastewater containing copper and nickel ions to reduce fresh water consumption and environmental degradation was investigated. In this work, the removal of copper (Cu2+) and nickel (Ni+) ions from synthetic water was studied on pilot scale remove by before using two commercial nanofiltration (NF) and reverse osmosis(RO) spiral-wound membrane modules (NE2521-90 and RE2521-FEN by Toray Chemical). The influence of main operating parameters such as feed concentration on the heavy metals rejection and permeate flux of both membranes, was investigated. Synthetic plating wastewater samples containing copper ($Cu^{2+}$) and nickel ($Ni^{2+}$) ions at various concentrations(1, 20, 100, 400 mg/L) were prepared and subjected to treatment by NF and RO in the pilot plant. The results showed that NF, RO process, with 98% and 99% removal for copper and nickel, respectively, could achieve high removal efficiency of the heavy metals.

정밀여과를 이용한 역삼투법 해수담수화 전처리 공정의 장기운전 특성 (Long Term Operation of Microfiltration as a Pretreatment for Seawater Reverse Osmosis Processes)

  • 김수한;김충환;강석형;임재림
    • 상하수도학회지
    • /
    • 제24권6호
    • /
    • pp.735-741
    • /
    • 2010
  • A pilot test was carried out to investigate the long term operation characteristics of Microfiltration (MF) system as a pretreatment for seawater reverse osmosis (SWRO) processes for two years. A commercialized MF module with pressurized operation type was used to filter seawater to remove particles which can foul reverse osmosis (RO) membrane. Silt Density Index (SDI) values of filtered seawater by the MF system were ranged from 0.14 to 1.79, which meet the SDI standard for RO feed water as depicted in previous literatures. Although the tested seawater is quite clean (i.e., dissolved organic cabon (DOC) concentration and turbidity were about 1 mg/l and less than 1 NTU, respectively) enough not to foul the MF membrane, steep increase in trans-membrane pressure (TMP) with a constant flux were observed over a whole operation period. A set of operation and water analysis data implies that the steep increase in TMP was resulted from iron and maganese fouling by the combination of metal corrosion by seawater and oxidation state by aeration and residual chlorine.

Seawater-driven forward osmosis for direct treatment of municipal wastewater

  • Sun, Yan;Bai, Yang;Tian, Jiayu;Gao, Shanshan;Zhao, Zhiwei;Cui, Fuyi
    • Membrane and Water Treatment
    • /
    • 제8권5호
    • /
    • pp.449-462
    • /
    • 2017
  • Direct treatment of municipal wastewater by forward osmosis (FO) process was evaluated in terms of water flux decline, reverse salt diffusion, pollutants rejection and concentration efficiency by using synthetic seawater as the draw solution. It was found that when operating in PRO mode (active layer facing the draw solution), although the FO membrane exhibited higher osmotic water flux, more severe flux decline and reverse salt diffusion was also observed due to the more severe fouling of pollutants in the membrane support layer and accompanied fouling enhanced concentration polarization. In addition, although the water flux decline was shown to be lower for the FO mode (active layer facing the feed solution), irreversible membrane fouling was identified in both PRO and FO modes as the water flux cannot be restored to the initial value by physical flushing, highlighting the necessity of chemical cleaning in long-term operation. During the 7 cycles of filtration conducted in the experiments, the FO membrane exhibited considerably high rejection for TOC, COD, TP and $NH_4{^+}-N$ present in the wastewater. By optimizing the volume ratio of seawater draw solution/wastewater feed solution, a concentration factor of 3.1 and 3.7 was obtained for the FO and PRO modes, respectively. The results demonstrated the validity of the FO process for direct treatment of municipal wastewater by using seawater as the draw solution, while facilitating the subsequent utilization of concentrated wastewater for bioenergy production, which may have special implications for the coastline areas.

Acrylic폐수의 전처리 및 UF/RO공저의 적용 (Pretreatment of Acrylic Wastewater and Application of UF/RO Processes)

  • 이광현
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2001년도 춘계 총회 및 학술발표회(한국막학회)
    • /
    • pp.135-138
    • /
    • 2001
  • 본 연구는 acrylic폐수의 COD제거를 위한 전처리 공정 및 전 처리된 acrylic폐수를 한외여과 중공사형 모듈과 역삼투 나권형 모듈에 적용하여 투과 플럭스를 고찰하였다. 이로부터 한외여과 및 역삼투 막의 적정 역세척 시간을 결정하고, 운전시간에 따른 막오염을 고찰하였다. 12시간을 기준으로 한외여과 중공사형 모듈에서의 flux가 급격히 떨어지고 있으며 역삼투 나권형 모듈도 비슷한 경향을 나타내고 있다. C3O 및 활성탄으로 전처리된 처리수의 COD, TDS는 한외여과 및 역삼투 공정만으로는 배출허용기준치 이하로 제거하기 어려우므로 UF/RO 공정 적용을 위한 전처리 공정의 개선이 필요하다.

  • PDF

폴리아미드 역삼투막을 이용한 염화나트륨, 아세트산나트륨, 구연산나트륨 용액의 농축 (Concentration of Sodium Chloride, Sodium Acetate and Sodium Citrate Solutions by using Polyamide Reverse Osmosis Membrane)

  • 이흥길;김인호
    • Korean Chemical Engineering Research
    • /
    • 제56권5호
    • /
    • pp.679-686
    • /
    • 2018
  • 폴리아미드 역삼투막을 이용하여 염화나트륨, 아세트산나트륨, 구연산나트륨 용액의 역삼투 농축실험을 행하고, 농도분극 현상을 압력, 용질의 종류, 농축액의 초기 농도를 변수로 연구하였다. 투과 플럭스에 대한 압력과 농도의 영향을 살펴보면, 공정 압력이 증가할수록 그리고 원액의 초기 농도가 작을수록 투과플럭스가 증가하였다. 농도분극이 일어나면 막 표면의 농도가 증가하여 투과플럭스가 감소한다. 농도분극은 농축이 진행됨에 따라 투과 플럭스의 감소로 이어지고 농도분극 층에서 용질 역확산을 통하여 점차 감소하였다. 이온의 크기, 분자량, 전하량이 증가함에 따라 막표면에서 정전기적 반발력이 커서 농도분극의 이론적 해석과 실험값의 차이가 컸다.

Choline chloride-Glycerol (1:2 mol) as draw solution in forward osmosis for dewatering purpose

  • Dutta, Supritam;Dave, Pragnesh;Nath, Kaushik
    • Membrane and Water Treatment
    • /
    • 제13권2호
    • /
    • pp.63-72
    • /
    • 2022
  • Choline chloride-glycerol (1:2 mol), a natural deep eutectic solvent (NADES) is examined as a draw solution in forward osmosis (FO) for dewatering application. The NADES is easy to prepare, low in toxicity and environmentally benign. A polyamide thin film composite membrane was used. Characterization of the membrane confirmed porous membrane structure with good hydrophilicity and a low structural parameter (722 ㎛) suitable for FO application. A dilute solution of 20% (v/v) NADES was enough to generate moderate water flux (14.98 L m-2h-1) with relatively low reverse solute flux (0.125 g m-2h-1) with deionized water feed. Application in dewatering industrial wastewater feed showed reasonably good water flux (11.9 L m-2h-1) which could be maintained by controlling the external concentration polarization and fouling/scaling mitigation via simple periodic deionized water wash. In another application, clarified sugarcane juice could be successfully concentrated. Recovery of the draw solute was accomplished easily by chilling utilizing thermo responsive phase transition property of NADES. This study established that low concentration NADES can be a viable alternative as a draw solute for dewatering of wastewater and other heat sensitive applications along with a simple recovery process.

정수기용 역삼투 폐분리막 필터의 세정 및 성능 향상 연구 (Cleaning of the Waste Reverse Osmosis Membrane Filters for the Household Water Purifier and Their Performance Enhancement Study)

  • 조영주;임지원
    • 멤브레인
    • /
    • 제27권3호
    • /
    • pp.232-239
    • /
    • 2017
  • 본 연구에서는 사용 후 폐기되는 정수기용 역삼투(Reverse Osmosis; RO)막 필터를 세정하여 새 필터의 수준으로 복원시키는 연구를 수행하였다. 화학적 세정액으로는 수산화나트륨, 중아황산나트륨, EDTA용액을 사용하였으며 마이크로버블 발생 장치와 함께 in-situ의 방법으로 세정하였다. EDTA를 0.1%의 농도로 제조한 뒤 마이크로버블과 함께 사용하여 30분 세정하였을 때 가장 좋은 결과를 나타내었다. 이때 폐 필터와 세정 후 폐필터의 성능을 비교해 보았을 때 투과도는 19.9%, 회수율은 49.5%증가하였으며 NaCl 100 mg/L 용액에 대한 염제거율은 2.3% 감소되었는데, 이는 새 필터와 동등한 수준으로 회복이 되었다. 또한 전자현미경 분석을 이용하여 막 표면의 오염물의 제거를 육안으로 확인하였다. 이로써 전량 매립 또는 소각 되어지는 정수기용 폐 RO막 필터의 세정을 통하여 재사용이 가능할 것으로 판단된다.

정삼투 분리막 공정 적용을 위한 n-nitrilotris(methylene) Phosphonic Acid Potassium Salt 유도용질의 합성 (Synthesis of n-nitrilotris(methylene) Phosphonic Acid Potassium Salt as a Draw Solute in Forward Osmosis Process)

  • 이혜진;최진일;권세이;김인철
    • 멤브레인
    • /
    • 제28권5호
    • /
    • pp.368-377
    • /
    • 2018
  • 정삼투 공정에 유용한 유도용질로서 n-nitrilotris(methylene) phosphonic acid (NTPA) 염을 합성하였다. NTPA에 첨가하는 KOH의 함량을 변화시켜 NTPA-4K, NTPA-5K, NTPA-6K 세 종류의 유도용질을 합성하고 $^1H$-NMR, $^{13}C$-NMR을 통하여 확인하였다. 유도용질의 물성을 확인하기 위해 삼투압, 점도, 수투과도, 역염 투과도를 측정하였다. 정삼투 공정에서는 증류수를 유입용액으로 사용하고 0.5 M의 유도용액으로 실험한 결과 각각 수투과도는 35.8, 38.8, 42.2 LMH를 나타내고 5.4, 6.9, 7.4 gMH의 역염 투과도를 나타내었다. 이는 기존의 NaCl 유도용액보다 높은 수투과도와 훨씬 낮은 역염 투과도를 확인하였다. 정삼투 공정 후 묽어진 유도용질의 회수를 위해 나노여과 방식으로 상용막을 사용하여 제거율을 측정한 결과 90% 이상의 높은 성능을 확인하였다.