• 제목/요약/키워드: Flushing system

Search Result 129, Processing Time 0.025 seconds

Effect of Water-Back-Flushing Time on Recovery Efficiency in Ceramic Filtration System for Paper Wastewater Treatment (세라믹 여과 시스템으로 제지폐수 처리시 회수 효율에 대한 물 역세척 시간의 영향)

  • Park Jin Yong
    • Membrane Journal
    • /
    • v.14 no.4
    • /
    • pp.329-338
    • /
    • 2004
  • In this study the discharged wastewater from paper manufacturing plant was filtrated by 4 kinds of tubular ceramic microfiltration and ultrafiltration membranes (carbon material) with periodic water-back-flushing, and we tried to find the optimum back-flushing time (BT). As results of water-BT effect for each ceramic membrane, the longer BT was more effective for a membrane having the larger pore size. And we could acquire the most volume of total permeate and the highest recovery efficiency of purified water, Then, the results of permeate flux vs. initial permeate flux during 180 min's operation showed that the longer BT was more effective for longer filtration time (FT) to obtain the higher permeate flux because membrane fouling proceeded deeply at long FT condition. And the optimum BT that founded from the trends of membrane fouling resistances almost accorded with the optimum BT from the trends of permeate flux, too.

Rainwater Harvesting System as an Alternative Water Source

  • Kim, Phil-S.;Yoo, Kyung-H.;Kim, Sun-Joo;Lee, Nam-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.524-528
    • /
    • 2009
  • The objectives of this study were to install RCR systems at a typical single family house and a school in Alabama, and evaluate the feasibility and efficiency of using the RCR systems for water harvesting in Alabama. The RCR systemswere equipped with a control system and a CR10X data logger to monitor the system operation and to collect data on precipitation, temperature, overflow, water depth in the storage tank and daily uses of toilet flushing. Daily average water use of the home for toilet flushing was 95 liter and 2100 liter was used at the school during the school days. Rainwater harvesting efficiency was 83.3 and 89 percent and RCR use efficiency was 18 and 98 percent from the home and the school, respectively. A computer program was developed to estimate potential effectiveness of RCR systems. From the analysis result with 10 years rainfall data, a total of 67,000 liters of rainwater could be harvested for domestic uses from a typical single family house which supplies 190 liters per day.

  • PDF

Container System Actively Maintaining High CO2 Concentration for Improved Sensory Quality of Kimchi

  • Lee, Hye Lim;An, Duck Soon;Jung, Yong Bae;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.22 no.3
    • /
    • pp.79-84
    • /
    • 2016
  • A kimchi container actively controlling $CO_2$ concentration by timely flushing of $CO_2$ gas was structured and tested in its capability and effectiveness because high $CO_2$ concentration enhances the sensory flavor of the product. The inlet and outlet valves of $CO_2$ gas were programmed to open and close allowing synchronous vent/$CO_2$ flush according to the requirements of its dissolution in the contained kimchi. During the chilled storage, the headspace of container could be maintained at desired high $CO_2$ concentration providing the preferred kimchi in sensory quality compared to control of the conventional container. However, there was no significant difference between the high $CO_2$ container and control (container simply closed with air) in kimchi quality attributes of pH, titratable acidity, total viable bacterial count, Lactobacillus sp. count and Leuconostoc sp. count. The flow rate and time interval of $CO_2$ flushing need to be adjusted considering the kimchi amount, headspace volume and ripening time. The designed system has potential to be applied in refrigerator appliances in homes and food service industry.

Permeation Behavior of Semiconductor Rinsing Wastewater Containing Si Particles in Ultrafiltration System -I. Permeation Characteristics of Polysulfone Flat Plate Membrane- (Si 입자를 함유한 반도체 세정폐수의 한외여과 특성[I] -Polysulfone 평판막에 의한 투과분리-)

  • 곽순철;이석기;전재홍;남석태;최호상
    • Membrane Journal
    • /
    • v.8 no.2
    • /
    • pp.102-108
    • /
    • 1998
  • Permeation behavior of the semiconductor rinsing wastewater containing Si particles was examined by ultrafiltration using the polysulfone plate membrane. The permeation flux was gradually decreased with time. It was due to the growth of cake deposited on the membrane surface and the pore plugging by Si particles. Permeation flux of cross flow type was 1.4 times higher than that of the dead end flow type. Nitrogen back flushing which is the removing method of membrane fouling was superior to the water sweeping. With nitrogen back flushing, the decrease of permeation flux due to the fouling was recovered about 85 % to the initial flux in the flat plate membrane system. The rejection rate of Si particles was about 90 % and the size of Si particle in the permeate was about 70 nm.

  • PDF

Atmosphere and Green Pepper Quality Influenced by Active Air Flushing in Fresh Produce Container Controlled in Real-time $O_2$ Concentration (실시간 $O_2$ 농도 제어 풋고추 용기에서 능동기체치환 시스템이 기체조성과 품질보존에 미치는 효과)

  • Jo, Yun Hee;An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.20 no.2
    • /
    • pp.29-33
    • /
    • 2014
  • Active air flushing mini-pumps were installed in a rigid polypropylene container ($32cm{\time}23cm{\time}18cm$) containing 900 g of fresh green peppers for effectively controlling its $O_2$ concentration on real time basis to preserve the product quality. The performance of the constructed system was compared to that of the modified atmosphere (MA) container system with gas diffusion tube controlled in close/open cycles responding to real time $O_2$ concentration at 10 and $20^{\circ}C$. In the control logic, the $O_2$ concentration was programmed to be located exactly at 13% or stay in the range of 13-15%. The active air flushing system could control the $O_2$ concentration in the desired level or range at both temperatures, while the passive diffusion system could work only under the low temperature condition of $10^{\circ}C$. At higher temperature of $20^{\circ}C$, the passive diffusion system could not manage the produce respiration increased more highly than the gas transfer through the diffusion tube, resulting in too low $O_2$ concentration and too high $CO_2$ concentration which would be injurious to the green pepper. When tested at $20^{\circ}C$, the MA container system could preserve the green pepper better than the perforated air package in terms of weight loss, ascorbic acid and chlorophyll contents and firmness.

  • PDF

Column cleaning, regeneration and storage of silica-based columns (실리카 기반 컬럼의 세척, 재생 및 보관 가이드)

  • Matt James;Mark Fever
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.1.1-1.4
    • /
    • 2024
  • This article provides comprehensive guidance on the maintenance, cleaning, regeneration, and storage of silica-based HPLC (High-Performance Liquid Chromatography) columns. The general considerations emphasize the importance of using in-line filters and guard cartridges to protect columns from blockage and irreversible sample adsorption. While these measures help, contamination by strongly adsorbed sample components can still occur over time, leading to an increase in back pressure, loss of efficiency, and other issues. To maximize column lifetime, especially with UHPLC (Ultra-High Performance Liquid Chromatography) columns, it is advisable to use ultra-pure solvents, freshly prepared aqueous mobile phases, and to filter all samples, standards, and mobile phases. Additionally, an in-line filter system and sample clean-up on dirty samples are recommended. However, in cases of irreversible compound adsorption or column voiding, regeneration may not be possible. The document also provides specific recommendations for column cleaning procedures, including the flushing procedures for various types of columns such as reversed phase, unbonded silica, bonded normal phase, anion exchange, cation exchange, and size exclusion columns for proteins. The flushing procedures involve using specific solvents in a series to clean and regenerate the columns. It is emphasized that the flow rate during flushing should not exceed the specified limit for the particular column, and the last solvent used should be compatible with the mobile phase. Furthermore, the article outlines the storage conditions for silica based HPLC columns, highlighting the impact of storage conditions on the column's lifetime. It is recommended to flush all buffers, salts, and ion-pairing reagents from the column before storage. The storage solvent should ideally match the one used in the initial column test chromatogram provided by the manufacturer, and column end plugs should be fitted to prevent solvent evaporation and drying out of the packing bed.

  • PDF

A pediatric case of idiopathic Harlequin syndrome

  • Kim, Ju Young;Lee, Moon Souk;Kim, Seung Yeon;Kim, Hyun Jung;Lee, Soo Jin;You, Chur Woo;Kim, Jon Soo;Kang, Ju Hyung
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.sup1
    • /
    • pp.125-128
    • /
    • 2016
  • Harlequin syndrome, which is a rare disorder caused by dysfunction of the autonomic system, manifests as asymmetric facial flushing and sweating in response to heat, exercise, or emotional factors. The syndrome may be primary (idiopathic) with a benign course, or can occur secondary to structural abnormalities or iatrogenic factors. The precise mechanism underlying idiopathic harlequin syndrome remains unclear. Here, we describe a case of a 6-year-old boy who reported left hemifacial flushing and sweating after exercise. He had an unremarkable birth history and no significant medical history. Complete ophthalmological and neurological examinations were performed, and no other abnormalities were identified. Magnetic resonance imaging was performed to exclude lesions of the cerebrum and cervicothoracic spinal cord, and no abnormalities were noted. His final diagnosis was classic idiopathic harlequin syndrome. Herein, we report the first pediatric case of idiopathic harlequin syndrome in Korea.

Effects of Moxibustion on Physiological Indices and Autonomic Nervous Symptoms in Adults with Prehypertension (뜸요법이 전고혈압 성인의 생리적 지수와 자율신경계 증상에 미치는 효과)

  • Cho, Soon-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.5
    • /
    • pp.686-694
    • /
    • 2010
  • Purpose: This study was done to examine the effects of moxibustion on physiological indices, such as 24-hr blood pressure, pulse pressure, and pulse rate, and autonomic nervous symptoms among adults with prehypertension. Methods: Participants were adults whose systolic and diastolic blood pressures were in the prehypertension stage and were not under treatment for the condition. Both experimental and control group consisted of 13 participants who were taking classes on acupuncture and moxibustion at a private institute. The experimental group received moxibustion once a day for 15 min, at least 5 days a week for 8 weeks. The results were analyzed using $x^2$-test, t-test, Fisher's exact test, Wilcoxon rank sum test and repeated measures ANOVA with the SAS program. Bonferroni correction method was adopted for multiple comparisons. Results: No significant change was observed in the 24-hr systolic and diastolic blood pressure between the two groups. Differences in the 24-hr pulse pressure and pulse rate were also not significant. However, significant decreases in headache, symptoms of flushing and fatigue were observed in the experimental group. Conclusion: The results suggest that moxibustion contributes to alleviating symptoms such as headache, flushing and fatigue associated with the autonomic nervous system among adults with prehypertension.