• Title/Summary/Keyword: Flush-out

Search Result 79, Processing Time 0.021 seconds

Reduction of Indoor VOCs' Concentrations using Flush-out in a Newly Built Apartment (신축공동주택에서 플러쉬아웃 실시에 따른 실내 VOCs 농도저감 효과에 관한 연구)

  • Park, Sang-In;Park, Jun-Seok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.57-63
    • /
    • 2018
  • The purpose of this study was to confirm the effects of flush-out on the reduction of Volatile Organic Compounds(VOCs) concentration in newly built residential buildings. The field measurements were conducted in two complexes of multi-residential buildings which are located suburban areas of Seoul. About three samples of residential buildings were selected in the field measurements. Two samples, B and C, had been flush-out with outdoor air more than seven days. The sample A was maintained at same condition during the flush-out because of the comparison. The indoor concentrations of VOCs in the three samples were measured at three times, before, during, and after flush-out. From the field measurements, it was confirmed that two samples' indoor VOCs' concentrations were considerably decreased after the flush-out comapred with those of the sample A in which the flush-out was not conducted. The decreases of indoor VOCs concentrations were corresponding to about 50% ~ 92% of the concentrations of before. Through the reviews for the previous studies, it was also found that the reduction effects of the flush-out is similar with the those of the bake-out which were reported in the previous studies.

Effects of Flush-out in the Reduction of Formaldehyde in Newly Built Residential Buildings (신축 공동주택에서 플러쉬아웃에 따른 폼알데하이드 농도 저감 효과에 관한 연구)

  • Park, Sang In;Kim, Joo Han;Park, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.116-122
    • /
    • 2018
  • The purpose of this study was to confirm the effects of flush-out in the reduction of formaldehyde concentration in newly built residential buildings. The field measurements were conducted on two complexes of multi-residential buildings which are located in the suburban area of Seoul. About eight samples of residential buildings were selected to measure the changes in formaldehyde concentrations after flush-out from the two apartment complexes. The concentration of formaldehyde was measured using DNPH cartridge and HPLC. From the results of the field measurements, it was established that indoor formaldehyde concentration decreases 27.6~54.2% in the samples after flush-out. The number of days that the flush-out were conducted was noted to have no significant influence on the reduction rate of formaldehyde concentration when the flush-out continued more than 7 days. The comparison with Bake-out showed that flush-out also can reduce formaldehyde in newly built buildings as same levels of it.

Study of Energy Cost for Performing Flush-out in Newly Constructed Multi-residential Buildings during Winter Season (겨울철 신축 공동주택의 플러쉬아웃 시행 시 난방비용에 관한 연구)

  • Lee, Ki Yong;Kim, Kee Han;Park, Jun-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.110-114
    • /
    • 2016
  • Newly constructed multi-residential buildings with more than 500 households should be flushed out indoor contaminants using a mechanical ventilation system or large fans after the completion of construction and prior to occupancy by the Heath-friendly Housing Construction Standards since 2014. In addition, the standard recommends to maintain indoor temperature over $16^{\circ}C$ and relative humidity below 60% while performing the flush-out. However, it is difficult to maintain these recommended indoor conditions, especially during winter season because additional energy cost is needed for space heating. Therefore, in this study, additional energy cost including heating and ventilation energy cost in multi-residential household for flush-out during winter season was estimated using building energy simulation program called EnergyPlus. Additional energy cost according to various conditions for performing flush-out (such as performance period, ventilation rate, and heating set-point temperature) was analyzed. Based on the results of the energy simulation, the energy cost was estimated to be ranged from 14,625 to 29,452\/household in Incheon city and from 3,521 to 26,268\/household in Gwangju City. There was no significant change in energy cost according to the performing terms of flush-out between Incheon and Gwangju City.

Comparison of Rainfall-Runoff Characteristics at Stream in Urban and Rural Watershed (도시 및 농촌 유역 하천에서의 강우유출 특성 비교)

  • Kim, Ho-Sub;Kim, Sang-Yong;Park, Yun-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.6
    • /
    • pp.650-660
    • /
    • 2018
  • The objective of this study was to compare the rainfall-runoff characteristics in streams of classified urban and rural watershed using land use and population density. EMC (event mean concentration) of BOD, COD, TP and SS increased significantly in urban and rural watershed, but that of TN remained unchanged. Although there were no significant differences in EMC of BOD, COD, TN, TP depending on the watershed characteristics, EMC of BOD and COD significantly increased in the urban watershed, while EMC of TP increased in the rural watershed. In the urban watershed, the first flush time was faster and the first flush effect was stronger in BOD, COD, and TP. However, the difference between cumulative mass and cumulative volume was found to be less than 0.2 in the rural watershed, indicating a weak first flush effect. The discharged masses of BOD (70 %), COD (64 %), and TP (66 %) in the first flush of runoff were higher in urban watershed, while TN (67 %) was higher in rural watershed. The reproducibility of first flush time and the strength of first flush using CV (coefficient of variation) was found to be more reproducible for first flush time in both watersheds. In rural watershed, the CV value of first flush time for TP out of water quality parameters was lower. Whereas the CV values of first flush time for BOD, COD and TP in urban watersheds were similar.

Clinical Trial to Evaluate the Hot Flush Relief Efficacy and Safety of Yiseontang-gami in Climacteric Women with Hot Flushes (갱년기 여성의 안면홍조에 대한 이선탕가미방(二仙湯加味方)의 증상 완화 효과 및 안전성 평가를 위한 임상연구)

  • Jung, Su-Kyoung;Kim, Dong-Il
    • Journal of Oriental Medical Thermology
    • /
    • v.7 no.1
    • /
    • pp.1-13
    • /
    • 2009
  • Purpose: To evaluate the hot flush relief efficacy of Yiseontang-gami in climacteric women with hot flushes, a vasomotor symptom. Methods: The 20 subjects who signing on the clinical trial written consent by self-will is registered this clinical trial after decided suitable by selection and exception standard, after take a medical experiment and checkup according to clinical trial plan. Registered subject should valuated by settled schedule after take the testing medicine(Yiseontang-gami)during thirty-day. The evaluating indexes of this trial are hot flush VAS, hot flush frequency, hot flush consistence time, sweating VAS, palpitation VAS, sleep disturbance VAS, MRS, MENQOL, PGA. Results: The results were as follows 1. 4 subjects dropped out of the clinical trial and 16 subjects completed it. 2. After Yiseontang-gami treatment, hot flush VAS, hot flush frequent, sweating VAS, Palpitation VAS, sleep disturbance VAS improved significantly. 3. After Yiseontang-gami treatment, hot flush consistence time was not improved significantly. 4. After Yiseontang-gami treatment, blood test value were not different significantly. Conclusion: In this clinical trial we consider that Yiseontang-gami is suitable treatment for the hot flushes and related symptoms.

  • PDF

Clinical Trial to Evaluate the Hot Flush Relief Efficacy and Safety of Yiseontang-gami in Climacteric Women with Hot Flushes (갱년기 여성의 안면홍조에 대한 이선탕가미방(二仙湯加味方)의 증상완화 효과 및 안전성 평가를 위한 임상연구)

  • Jung, Su-Kyoung;Kim, Dong-Il
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.21 no.3
    • /
    • pp.75-89
    • /
    • 2008
  • Purpose: To evaluate the hot flush relief efficacy of Yiseontang-gami in climacteric women with hot flushes, a vasomotor symptom. Methods: The 20 subjects who signing on the clinical trial written consent by self-will is registered this clinical trial after decided suitable by selection and exception standard, after take a medical experiment and checkup according to clinical trial plan. Registered subject should valuated by settled schedule after take the testing medicine(Yiseontang-gami)during thirty-day. The evaluating indexes of this trial are hot flush VAS, hot flush frequency, hot flush consistence time, sweating VAS, palpitation VAS, sleep disturbance VAS, MRS, MENQOL, PGA. Results: The results were as follows 1. 4 subjects dropped out of the clinical trial and 16 subjects completed it. 2. After Yiseontang-gami treatment, hot flush VAS, hot flush frequent, sweating VAS. Palpitation VAS, sleep disturbance VAS improved significantly. 3. After Yiseontang-gami treatment, hot flush consistence time was not improved significantly. 4. After Yiseontang-gami treatment, blood test value were not different significantly. Conclusion: In this clinical trial we consider that Yiseontang-gami is suitable treatment for the hot flushes and related symptoms.

  • PDF

An Analysis on the First Flush Phenomenon by Stormwater Runoff in Eutrophic Lake Watershed (부영양상태 호수유역의 강우유출수에 의한 초기세척효과 분석)

  • Cho, Jae-Heon;Seo, Hyung-Jun
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.5
    • /
    • pp.341-350
    • /
    • 2007
  • Lake Youngrang is a lagoon whose effluent flows into the East Sea. Because two resort towns and two golf courses are situated at the lake basin, many tourists visit this area. Stormwater runoff surveys were carried out for the eight storm events from 2004 to 2005 in the eutrophic lake watershed to give a basic data for the diffuse pollution control of the lake. Dimensionless mass-volume curves indicating the distribution of pollutant mass vs. volume were used to analyze the first flush phenomenon. The mass-volume curves were fitted with a power function and polynomial equation curves. The regression analysis showed that the polynomial equation curves were better than the power function in representing the tendency of the first flush, and second degree polynomial equation curves indicated the strength of the first flush effectively.

Evaluation of First Flush Rainfall Inflow and Pollution Loads into Manhole against Combined and Sanitary Sewer Overflows (초기우수 관거유입계수 산정 및 오염부하 기여도 평가)

  • Kim, Hongtae;Shin, Dongseok;Kim, Yongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.67-70
    • /
    • 2015
  • Some data into combined and sanitary sewer system were collected in order to find out the characteristics of discharge from first flush rainfall inflow. The inflow ratios of combined and sanitary sewer system were 0.46 and 0.27 during rains from various survey data. The average inflow ratio 0.31 was appropriate for general application because many watersheds were not classified clearly as combined or sanitary sewage treatment areas. The percentage of first flush loads in the whole BOD load was about 10%. This result was thought some meaningful, comparing with similarity of first flush pollution load contribution previous surveyed by KECO (2004).

Effect of Grass Silage Supplementation on Performance in Lactating Cows Grazing on Pasture

  • Sung, K.I.;Okubo, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.10
    • /
    • pp.1409-1418
    • /
    • 2001
  • Two trials were carried out during two different grazing seasons to evaluate effect of grass silage supplementation, when amount of pasture is limited on dry matter intake (DMI), milk production, and gross energetic efficiency (GEE) of grazed lactating cows on a high forage-based diet. Fifty-one Holstein cows were randomly assigned to one of two dietary treatments: high pasture group or high silage group. In the spring flush, pasture and silage DMI, milk yield, milk fat percentage, and GEE were not different between the dietary groups. After the spring flush, pasture and silage DMI were higher for the high silage group than for the high pasture group. After the spring flush, although these were the higher total DMI of the high silage group than the high pasture group, milk yield was significantly (p<0.05) higher for the high pasture group than the high silage group. Milk fat percentage tended to be higher for the high silage group than the high pasture group. The GEE was significantly (p<0.05) higher for the high pasture group than the high silage group during after the spring flush. This study indicated that supplementation of grass silage, especially after the spring flush, can have a significant effect of increasing of forage intake and maintenance of the milk fat percentage; but not increase milk yield and GEE.

Critical Influence of Rivet Head Height on Corrosion Performance of CFRP/Aluminum Self-Piercing Riveted Joints

  • Karim, Md Abdul;Bae, Jin-Hee;Kam, Dong-Hyuck;Kim, Cheolhee;Park, Yeong-Do
    • Corrosion Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.92-101
    • /
    • 2019
  • This study investigates how rivet head height affects the corrosion performance of carbon fiber reinforced plastic (CFRP) to aluminum alloy self-piercing riveted joints. Specimens with two different head heights were prepared. A rivet head protruding out of the top CFRP laminate forms the proud head height while a rivet head penetrating into the top CFRP generates the flush head height. The salt spray test evaluated corrosion performance. The flush head joints suffered from severe corrosion on the rivet head. Thus, the tensile shear load of flush head joints was substantially reduced. Electrochemical corrosion tests investigated the corrosion mechanisms. The deeper indentation of the flush head height damaged the CFRP around the rivet head. The exposure of damaged fibers from the matrix increased the cathodic potential of local CFRP. The increased potential of damaged CFRP accelerated the galvanic corrosion of the rivet head. After the rivet head coating material corroded, a strong galvanic couple was formed between the rivet head base metal (boron steel) and the damaged CFRP, further accelerating the flush rivet head corrosion. The results of this study suggest that rivet head flushness should be avoided to enhance the corrosion performance of CFRP to aluminum alloy self-piercing riveted joints.