• Title/Summary/Keyword: Fluoride-Ion

Search Result 222, Processing Time 0.023 seconds

Study on the Distribution of Fluorides in Plants and the Estimation of Ambient Concentration of Hydrogen Fluoride Around the Area of the Accidental Release of Hydrogen Fluoride in Gumi (구미 불산 누출사고 지점 주변 식물의 불소화합물 농도 분포 및 공기 중 불화수소 농도 추정에 관한 연구)

  • Gu, Seulgi;Choi, Inja;Kim, Won;Sun, Oknam;Kim, Shinbum;Lee, Yungeun
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.4
    • /
    • pp.346-353
    • /
    • 2013
  • Objectives: The goal of this study is to identify the distribution of the foliar fluorine content of vegetation surrounding the area where hydrofluoric acid was accidently released in Gumi, Gyeongsangbuk-do on September 27, 2012. In addition, it also aims to estimate the concentration of hydrogen fluoride in the air on the day of the accident. Methods: Samples of plant leaves were collected on October 7, 2012 within 1 km from the site where the accident occurred. These samples were analyzed for soluble fluorine ion with an ion selective electrode. The ambient concentration of hydrogen fluoride was calculated using the fluoride content in the plant via the dose-rate equation (${\Delta}F$=KCT). Results: The arithmetic and geometric means of the concentrations were 2158.2 and 1183.7mg F $kg^{-1}$ for leaves and, 2.4 and 1.1 ppm HF for the air, respectively. The highest concentration of hydrogen fluoride in the air was 14.7 ppm, which is higher than the maximum concentration reported by the government (1 ppm) and the exposure limit (ceiling, 3 ppm). The concentrations of both fluorine and hydrogen fluoride decreased with increasing distance from the accident site and showed a significant decrease outside of a 500m radius from the site (p <0.05). Conclusions: The area around the accident site was highly polluted with hydrogen fluoride according to the results of this study. Considering the persistency of hydrogen fluoride in the environment, long-term monitoring and environmental impact assessment should be pursued.

Exposure Assessment Study on Lithium-Ion Battery Fire in Explosion Test Room in Battery Testing Facility

  • Mi Sung Jo;Hoi Pin Kim;Boo Wook Kim;Richard C. Pleus;Elaine M. Faustman;Il Je Yu
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.114-117
    • /
    • 2024
  • A lithium-ion battery is a rechargeable battery that uses the reversible reduction of lithium ions to store energy and is the predominant battery type in many industrial and consumer electronics. The lithium-ion batteries are essential to ensure they operate safely. We conducted an exposure assessment five days after a fire in a battery-testing facility. We assessed some of the potentially hazardous materials after a lithium-ion battery fire.We sampled total suspended particles, hydrogen fluoride, and lithium with real-time monitoring of particulate matter (PM) 1, 2.5, and 10 micrometers (㎛). The area sampling results indicated that primary potential hazardous materials such as dust, hydrogen fluoride, and lithium were below the recommended limits suggested by the Korean Ministry of Labor and the American Conference of Governmental Industrial Hygienists Threshold Limit Values. Based on our assessment, workers were allowed to return to work.

Anion Sensing Properties of New Colorimetric Chemosensors Based on Thiourea and Urea Moieties

  • Kim, Dong-Wan;Kim, Jung-Hwan;Hwang, Jae-Young;Park, Jong-Keun;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.1159-1164
    • /
    • 2012
  • A new colorimetric sensors containing thiourea (1-(4-nitrophenyl)-3-quinolin-6-ylthiourea; 1) and urea(1-(4-nitrophenyl)-3-quinolin-6-ylurea; 2) moieties for fluoride were designed and synthesized. These simple receptors were characterized their stoichiometry, and investigates the mechanism of their selectivity as anion receptors. The addition of tetrabutylammonium fluoride salts to the solution of receptors caused a dramatically and clearly observable color changes from colorless to yellow. To examine their application as anion receptors by UV-vis and $^1H$ NMR spectroscopy results revealed their higher selectivity for fluoride ion than other anions. The receptors and fluoride ion formed a 1:1 stoichiometry complex through strong hydrogen bonding interactions in the first step, followed by a process of deprotonation in presence of an excess of $F^-$ in DMSO solvent.

Low Dielectric Constant of MeV ion-Implanted Poly(vinylidene fluoride)

  • Lee, Sang-Yun;Kim, Bo-Hyun;Park, Soung-Kyu;Jinsoo Joo;Beag, Yowng-Whoan;Koh, Seok-keun
    • Macromolecular Research
    • /
    • v.11 no.1
    • /
    • pp.9-13
    • /
    • 2003
  • Poly (vinylidene fluoride) (PVDF) samples were implanted by using high energy (MeV)F$^{2+}$ and Cl$^{2+}$ ions. We observed that AC dielectric constant of the ion-implanted PVDF samples decreased from 10.5 to 2.5 at 1 kHz as the ion dosage increased from 10$^{11}$ to 3 $\times$ 10$^{14}$ ions/$\textrm{cm}^2$. From differential scanning calorimetry experiments, we observed that PVDF samples become more disordered state through the ion implantation. The decrease of the number of bonding of C-H and C-F and the increase of unsaturated bonding were observed from X-ray photoelectron spectroscopy experiments. The emission of HF and H$_2$ molecules during the ion implantation was detected by residual gas analyzer spectrum. Based upon the results, we analyzed that the low AC dielectric constant of the MeV ion-implanted PVDF samples originated from the reduction of polarization due to the structural change of the CF$_2$ molecules in the MeV ion-implanted PVDF samples.les.

Relationship of the use of some fluoride containing dentifrice on the korean market to children's fluoride intake in different age groups (국내 시판 일부 불소함유치약 사용 시 연령별 어린이 불소섭취량)

  • Lee, Kyeong-Hee;Choi, Choong-Ho;Hong, Suk-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.5
    • /
    • pp.881-896
    • /
    • 2012
  • Objectives : The purpose of this study was to examine the amount of daily fluoride intake among children using fluoride-containing dentifrice in an effort to pave the way for the selection of criteria for the development of safe dentifrice for different age groups to make a contribution to children's oral health. Methods : This study was implemented over approximately six months from May to October 2008 by recruiting subjects, asking their consent, conducting a survey, collecting samples and analyzing the collected data. The subjects in this study were preschool residents in Seoul and Gyeonggi province, who were at the western age of 2 to 5. The amount of fluoride withdrawn from their one-time toothbrushing was measured in two different ways. One was by using HMDS-facilitated modified diffusion method and fluoride ion electrode, and the other was by applying ion chromatography without the diffusion procedure. Results : The fluoride intake accounted for $46.5{\pm}19.1$ percent of the amount of fluoride used, and that percentage was statistically significantly different according to age(p<0.01). The one-time fluoride intake from dentifrice per weight(kg) was a mean of $0.009{\pm}0.006mg$. As a result of multiplying this amount by daily toothbrushing frequency, the daily fluoride intake from dentifrice per weight(kg) appeared to be $0.023{\pm}0.016mg$ on average. There was a large difference among the children in that regard, since that ranged from a low of 0.003mg to a high of 0.070mg. And age made a statistically significant difference to that(p<0.01). Conclusions : The above-mentioned findings of the study showed that the children's daily fluoride intake from dentifrice per weight was lower than the recommended daily fluoride intake from diets per weight for young children aged 1 to 12(0.05-0.07mg). However, there was a great disparity among the children in that aspect, and they are likely to take more fluoride from other things as well. Therefore it is required to prepare separate criteria for preschool and school-aged children.

Investigation on the material properties of Waste Oyster Shell to use as an Adsorbent for Fluoride Ion (불소(弗素) 이온 흡착제(吸着劑)로서의 활용(活用)을 위한 폐(廢)굴껍질의 특성(特性) 분석(分析))

  • Lee, Jin-Suk;Seo, Myung-Soon;Kim, Dong-Su
    • Resources Recycling
    • /
    • v.16 no.3 s.77
    • /
    • pp.12-18
    • /
    • 2007
  • The material properties of waste oyster shell, which is largely generated from the treatment of marine products, have been investigated for its possible utilization as an adsorbent for fluoride ion-containing wastewater. The major composition of waste oyster shell was analyzed to be $CaCO_3$ and loss of 46% in weight reduction occurred during its thermal treatment by the emission of moisture and $CO_2$. The surface structure of oyster shell was decomposed by the heating and its surface potential was negatively increased with pH. As the pH of wastewater was increased, the adsorbed amount of fluoride ion onto oyster shell was decreased and the wastewater was found to be neutralized during adsorption process by ${CO_2}^{3-}$ which generated from the partial dissolution of oyster shell

Cycling Performances of Lithium-Ion Polymer Cells Assembled with Surface-Modified Separators Containing Aluminum Fluoride (불화 알루미늄을 포함하는 표면 개질된 분리막으로부터 제조되는 리튬이온폴리머전지의 싸이클 특성에 관한 연구)

  • Eo, Seung-Min;Kim, Dong-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.2
    • /
    • pp.125-129
    • /
    • 2008
  • Rechargeable lithium-ion polymer batteries have been considered to be next-generation power sources for portable electronic devices and electric vehicles. In this work, we tried to improve the cycling performances of lithium-ion polymer cells by coating aluminum fluoride and acrylonitrile-methyl methacrylate copolymer to the polyethylene separator. It was found that the addition of aluminum fluoride to the surface-modified separator reduced the interfacial resistances and thus the cell exhibited a less capacity fading and better high rate performance. The cell showed an initial discharge capacity of 150 mAh/g and good capacity retention at 0.5 C rate.

Fluoride and Calcium in Tea Leaves

  • Takiyama, Kazuyoshi;Ishii, Yuuko
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.877-880
    • /
    • 1995
  • The determination of fluoride and the nutritious calcium in infusion of teas are explained. Tea leaves were pulverized and were immersed in boiling water. The solution was filtered and fluoride, calcium and oxalic acid were determined by the ion chromatography. The quantities of fluoride, calcium and oxalate ions extracted from 100 g of tea leaves were calculated. Tea leaves were also immersed in 0.5 M hydrochloric acid and extracted oxalate and calcium ions were analyzed. The free oxalic acid and calcium were extracted in boiling water and the total ones were extracted in hydrochloric acid. The quantity of calcium oxalate was calculated from the total and the free oxalic acids. The free calcium was estimated to be nutritious.

  • PDF

Performance of Membrane Capacitive Deionization Process Using Polyvinylidene Fluoride Heterogeneous Ion Exchange Membranes Part I : Preparation and Characterization of Heterogeneous Ion Exchange Membranes (폴리비닐플루오라이드 불균질 이온교환막을 이용한 막 결합형 축전식탈염공정의 탈염 성능 Part I : 불균질 이온교환막의 제조 및 특성)

  • Park, Cheol Oh;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.27 no.1
    • /
    • pp.84-91
    • /
    • 2017
  • In this study, heterogeneous ion exchange membranes were prepared by mixing cation or anion exchange resins and commercial polyvinylidene fluoride (PVDF) for MCDI process. The mixing ratios of PVDF and ion exchange resins were 1 : 1, 1.4 : 1, 2 : 1, and 3 : 1. We characterized SEM, water content, ion exchange capacity, methanol permeability, and ion conductivity. In the viewpoint of membrane characterization, the blending ratio of 2 : 1 showed the best. For the blending ratio of 2 : 1, heterogeneous cation exchange membrane showed the water content 34%, ion exchange capacity 1.54 meq/g, ion conductivity 0.019 S/cm, and methanol permeability $2.28{\times}10^{-7}{\sim}8.86{\times}10^{-7}cm^2/s$ while In the case of heterogeneous anion exchange membrane, the result showed 37%, 2.18 meq/g, and 0.034 S/cm and $1.46{\times}10^{-7}{\sim}8.66{\times}10^{-7}cm^2/s$.