• Title/Summary/Keyword: Fluorescent Lamps

Search Result 381, Processing Time 0.02 seconds

Electromagnetic distribution looped Electrodeless Fluorescent Lamps (환형 무전극 램프의 전자계 분포특성)

  • Jo, Ju-Ung;Lee, Seong-Jin;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.312-315
    • /
    • 2003
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[kHz] and some specific conditions.

  • PDF

A Study on Emission Characteristics of Ar Gas Using a Single Langmuir Probe Method in Radio-Frequency Inductively Coupled Plasma (13.56MHz ICP에서 단일 탐침법에 의한 Ar 가스의 발광특성 연구)

  • Jo, Ju-Ung;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.611-615
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, Electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The electrodeless fluorescent lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, electron temperature and electron density were measured in a radio-frequency inductively coupled plasma using a Langmuir probe method for emission characteristics. Measurement was conducted in an argon discharge for pressure from 10 [mTorr] and input RF power 100 [W] to 150 [W]. As for the electron density, a electron temperature was more distinguished for a emission characteristic. The results of ideal may contribute to systematic understanding of a electrodeless fluorescent lamps of emission characteristics.

  • PDF

Electromagnetic Properties of Ring-Shaped Electrodeless Fluorescent Lamps (환형 무전극 형광램프의 전자계특성)

  • Jo, Ju-Ung;Lee, Seong-Jin;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.521-524
    • /
    • 2003
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250kHz and some specific conditions.

  • PDF

The Comparison of the Economical Efficiency of Light Sources for a Tunnel Lighting (터널조명용 광원의 경제성 비교)

  • Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.32-42
    • /
    • 2011
  • In this paper to compare the economical efficiency of light sources for a tunnel lighting, we define a model tunnel and design tunnel lighting. And to examine economical efficiency of various tunnel lightings we compare the lighting expenses of tunnels. The results shows high pressure sodium lamps are more economical than fluorescent lamps.

A Study on the Dimming Control of Electrodeless Fluorescent Lamps (무전극 형광램프의 조광제어에 관한 연구)

  • Jang, Tae-Eun;Kim, Hee-Jun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.11
    • /
    • pp.553-560
    • /
    • 2005
  • This paper presents a study on the dimming control of electrodeless fluorescent lamp. To do this the equivalent model of electrodeless fluorescent lamp (ENDURA 100w Type) was first established. The resulted model of the lamp was applied to the two kinds of dimming control method, one is the variable switching frequency method and the other is the variable dc link voltage method. And the comparison results of the dimming characteristics between the two methods was presented. Theoretical predictions were verified by the experimental results on the ENDURA 100W type electrodeless fluorescent lame.

A Study on the Optical Characteristics of LED Lamp as Alternative Type of FPL Lamp (FPL형광램프 대체형 LED램프의 조도특성에 관한 연구)

  • Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.1-6
    • /
    • 2015
  • As lamps using LEDs are developed actively, also there have been large request for LED lamps that can replace traditional lamps like fluorescent lamps and metal halide lamps. But so far there are no proper standards that manufacturer can use and test their lamps. As a result of this, manufacturers are not only unable to develop LED lamps but also sell it even though they have technology. In this study, It is proposed that proper test method by investigating compatibility between all-type control gear and LED lamps by analyzing control gear for fluorescent lamp such as magnetic or electronic ballast that is currently used in the market.

Electronic Ballast of High Power Factor Using SEPIC Converter for Electrodeless Fluorescent Lamps (SEPIC 컨버터를 이용한 무전극형광램프용 고역률 전자식 안정기)

  • 장도현;주형종;권명일
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.285-293
    • /
    • 2004
  • In this Paper the electronic ballast using the SEPIC(Single Ended Primary Inductor Converter) converter for the multiple electrodeless fluorescent lamps is proposed, which has the structure of the active PFC and self oscillating function. The SEPIC converter system has the characteristics of the power factor with low input current harmonic distortion. The proposed control method is based on the aveage-current-mode using the dedicated integrated circuit UC3854. The proposed electronic ballast has the reduction effect for the energy and manufacturing cost because it is designed for tripple electrodeless fluorescent lamps. The experimental results shows that the power factor is higher and the THD is lower.

Design and Control of a Multi-Output Electronic Ballast Using Microcontroller (마이크로 컨트롤러를 이용한 가변출력형 전자식 안정기의 설계 및 제어)

  • 곽재영;여인선
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.4
    • /
    • pp.59-65
    • /
    • 1997
  • This paper proposes a new approach for the design of a multi-output electronic ballast for fluorescent lamps of different outputs and control method. At first, a standard-output electronic ballast is constructed and then fluorescent lamps with different outputs are lighted by the frequency control of inverter circuit using MeV. This multi-output electronic ballast consists of a rectifier circuit, an inverter circuit, and a frequency control circuit to determine the optimal frequency for the lamps of different output. In order to verify the proposed design method, a prototype of a multi-output electronic ballast for 11 [WJ. 15[WJ compact fluorescent lamps and 20W fluorescent lamp is constructed. Results of observing the voltage and current characteristics of lamps are in accord with those of PSpice simulation. Also its efficacy is nearly the same as the other electronic ballasts. From the result, therefore, validity of the proposed design method of a multi-output electronic ballast for fluorescent lamps is verified.

  • PDF

A Study on Pseudo DC Discharging Electronic Bal lasts for Fluorescent Lamp (의사 DC 방전용 형광등 전자 안정기에 관한 연구)

  • 이범익;정화진;지철근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.11-15
    • /
    • 1992
  • Currently-using low-pressure lamps are usually drivel by the AC power supply. There are good and bad points according to high or low frequency in AC power driving type. For the low-pressure lamps, its efficiency increases and flicker decreases when it ignites at high frequency. So we already use the high-frequency electronic ballast of the low-pressure discharge lamps broadly. But there are EMI interference in high-frequency driving type because of giving the fluorescent lamp the high- frequency current. So recently, we have a tendency to compensate for that defects by DC driving method. As follows, we suggest pseudo DC discharging electronic bar lasts for fluorescent lamps which have the characteristics of high efficiency and no flicker by driving constant current boosted square wave.

  • PDF

A study on the safety LED lamp using internal control gear as the alternative type of fluorescent lamp (형광램프 대체 컨버터 내장형 LED램프의 안전성 확보방안)

  • Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.30-38
    • /
    • 2015
  • As products using LEDs are developed actively, also there has been large request for LED products that can replace traditional lamps like fluorescent lamps and metal halide lamps. But so far there is no proper standard that manufacturer can use and test it. As a result manufacturer can't develop retrofit LED lamps and sell it even they have technology. In this study, by analyzing control gear for fluorescent lamp that is currently used in market which is magnetic or electronic ballast, I'd like to develop proper test method by investigating compatibility between all-type control gear and LED retrofit products.