• 제목/요약/키워드: Fluidity Concrete

Search Result 499, Processing Time 0.023 seconds

An Experimental Study on the Effect on Strength and Internal Structure for UHPC by Silics Fume Replacement Ratio (실리카 퓸의 첨가량에 따른 UHPC의 강도와 내부조직에 미치는 영향에 관한 실험적 연구)

  • Park, Jung-Jun;Kang, Su-Tae;Ryu, Gum-Sung;Koh, Gyung-Taek;Kim, Sung-Wook;Lee, Jang-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.765-768
    • /
    • 2008
  • Silica fume is a very important gradient in UHPC(Ultra High Performance Concrete) and its amount is normally over 25% of cement(wt.%). But we surely need to comprehend the influence of the amount of silica fume on the UHPC. In this paper, it was investigated how the amount of silica fume influence on the properties such as fluidity, compressive strength, elastic modulus, and flexural strength. Furthermore, it was examined the internal micro structure on UHPC through the test of SEM and MIP. In results, If we properly use silica fume in UHPC, fluidity and strength of UHPC was increased. It can be ascertained through the test of MIP that silica fume effectively increased density of UHPC by posolanic reaction and acting as filler. Especially, In case of Cement to silica fume ratio$0.1{\sim}0.25%$, we can be concluded that UHPC has similar to mechanical property.

  • PDF

Examination on Application of High-Performance Concrete using Fine Fly Ash as Replacement Material of Silica Fume (고성능콘크리트의 제조에 사용되는 실리카 흄의 대체재로써 고분말 플라이애시의 적용성 검토)

  • Lee, Bum-Sik;Kim, Sang-Kyu;Kim, Sang-Youn;Choi, Sun-Mi;Lee, Gun-Su
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.9
    • /
    • pp.502-509
    • /
    • 2007
  • This paper investigated how Fine Fly Ash (FFA) with $14,000\;cm^2/g$ of Fineness affects the micro structure and material properties of High-Performance Concrete (HPC) before and after hardening from Material Test of HPC and Cement Paste. FFA is applied as a substitute of Silica Fume which is used necessarily in producing HPC. As a Material Test results, 5% FFA series specimen shows the lower fluidity than SF series specimen. When, however, the Fluidity of 10% FFA series specimen is increased reversely to the similar value of SF series specimen. The Porosity of FFA series specimen of 3 day age is displayed to $21{\sim}24%$, which is higher than $19{\sim}20%$ porosity of SF series specimen, while that of 28 day age is reached to $8{\sim}9%$, which is improved compared with 10% fo SF series specimen. It can be thought that FFA has better influence on the porosity of HPC in case of long term age. The Compressive strength of FFA series specimen shows the similar result with the property of porosity. The compressive strength of 28 day age FFA series specimen is $98{\sim}106%$ of SF series specimen and 107% of plain specimen to reveal better strength development.

Fundamental Properties of Concrete Using Liquid Type High Early Strength Agent with Water to Binder Ratio (물결합재비 변화에 따른 액상형 조강제를 사용한 콘크리트의 기초적 특성)

  • Noh, Sang-Kyun;Oh, Sang-Baek;Lee, Gun-Cheol;Lee, Mun-Hwan;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.57-60
    • /
    • 2007
  • This study is to discuss the effect of the liquid type high early strength agent considering early strength, developing strength, and economics of the concrete using admixtures. The powder type high early strength agent does not helpful because the field application is not available such as the problem of mixing process and rack of economics. To make up these subjects, the plain mixture contains the standard type AE water reducing agent, and the types of the agents are the standard type AE water reducing agent(P),liquid type high early strength agent(AD),poly carboxylate high early strength type AE water reducing agent(E1), and naphthalene + melamine high early strength type AE water reducing agent(E2). As the Contents of the agents, E1 and E2 is two types each cases, and P is one type to satisfy the target fluidity and air content, AD is three types as 0.5, 1.0,and 1.5%. In the case that AD is mixed, the fluidity is decreased, but air content is increased. For increasing strength of the early age, using OPC is more effective than FA and BS for increasing the early strength of the concrete, and if the air content is secure as plain, the effect of the developing strength can be increased because the air content is increased about 2% in the case that AD is used.

  • PDF

Comparison Analysis of Fiber Distribution and Workability for Amorphous Steel Fiber Reinforced Concrete (비정질강섬유 보강콘크리트 작업성 및 섬유 분산성 비교분석)

  • Kim, Byoung-Il;Lee, Sea-Hyun
    • Resources Recycling
    • /
    • v.23 no.4
    • /
    • pp.47-57
    • /
    • 2014
  • The research was conducted to analyze workability and fiber distributions of amorphous steel fiber reinforced concrete by changing fiber length and fiber addition ratio. The inverted slump cone and vebe tests as well as slump test was performed to understand the fluidity of amorphous steel fibers which have quite different appearance compared to conventional steel fibers. Test results showed that thin plate type of amorphous steel fibers required different test approach to figure out workability since the reduction of workability from slump test was different that from inverted slump cone and vebe tests. In conclusion, fluidity of amorphous steel fibers to concrete was significantly degraded as fiber length and addition ratio increase. Also, fibers space in cement matrix was apparently reduced as the increase of fiber length and addition ratios without fiber balling.

Performance of Fresh and Hardened Ultra High Performance Concrete without Heat Treatment (상온 양생한 초고성능 콘크리트(UHPC)의 경화 전과 후의 성능 관계)

  • Kang, Sung-Hoon;Hong, Sung-Gul
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.1
    • /
    • pp.23-34
    • /
    • 2014
  • This study investigates the relationship between the performance of fresh and hardened Ultra-High Performance Concrete (UHPC) without heat treatment. The performance of fresh UHPC is determined by the slump flow test related to the fluidity of concrete mixtures, and the air content test. The variables of these tests are the water to binder ratio, superplasticizer dosages and volume fractions of steel fiber. Generally, insufficient fluidity and excessive air contents in concrete mixtures lead to the insufficient packing density related to the performance of harden concrete. The performance of hardened UHPC is determined by the compressive and flexural tensile tests. The results of the fresh UHPC tests show that there is the linear correlation between each variable and the slump flow diameter, and that the slump flow diameter is linearly decreased as the air content ratio increase. Using these results, the formula is developed to predict the fresh performance before mixing UHPC. The results of the hardened UHPC tests show that the hardened performance is not influenced by the air content ratio in the range of 3.2 to 4.2 per cent. However, the flexural tensile strength dominantly influenced by the volume fractions of steel fiber.

Fundamental and Shrinkage Properties of High Performance Concrete in Combined with Expansive Additive and Shrinkage Reducing Agent (팽창재와 수축저감제를 조합 사용한 고성능콘크리트의 기초물성 및 수축특성)

  • Han Cheon-Goo;Kim Sung-Wook;Koh Kyoung-Taek;Cheol Han-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.605-612
    • /
    • 2004
  • This study investigated the fundamental properties and shrinkage properties of high performance concrete with water/binder ratio of 0, 30 and with combination of expansive additive and shrinkage reducing agent. According to the results, the fluidity of high performance concrete showed lower the using method in combination with expansive additive and shrinkage reducing agent than the separately using method of that, so the amount of superplasticizer increased when the adding ratio of expansive additive and shrinkage reducing agent increased. However the air content of concrete increased when used in combination with expansive additive and shrinkage reducing agent, so the amount of AR agent decreased. The compressive strength showed the highest at $5\%$ of expansive additive, and decreased with an increase of the amount of shrinkage reducing agent. Furthermore, in order to reduce the shrinkage of high performance concrete, it was found that the using method in combination with expansive additive and shrinkage reducing agent was more effective than separately using method of that. Therefore, it analyzed that the combination of expansive additive of $5\%$ and shrinkage reduction agent of $1\%$ was the most suitable mixture, considering to the fluidity, strength and shrinkage under the condition of this experiment.

A Fundamental Study on the Effectiveness of Anti-freeze Agent Using Waste Coolant in Cold Weather Concreting (한중콘크리트에 있어서 폐부동액을 이용한 내한제의 효율성에 관한 기초적 연구)

  • Kim, Kyoung-Min;Won, Cheol;Kim, Gi-Cheol;Oh, Sun-Kyo;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.231-236
    • /
    • 2001
  • In this paper, tests are carried out in order to investigate the validities of anti-freeze agent, which is developed using waste coolant and existing anti-freeze agent through previous study, under various W/C and contents. According to test results, adequate dosage of developed anti-freeze agent shows positive performance in slump, air content and chloride contents in the mixture of 40% and 50% of W/C, accelerates setting time and drops the freezing temperature of concrete. Meanwhile, in the region of 30% of W/C, followings can be indicated that increasing the contents of anti-freeze agent leads to reduce fluidity, rapid setting and excessive chloride contents. Improved strength gain is shown when anti-freeze agent is used with in 8%.

  • PDF

Experimental Estimation of the Early Strength of Belite Cement Mortar Using Microwave (저열 포틀랜드(4종)시멘트 모르터의 마이크로파를 이용한 조기강도 추정에 관한 실험적 연구)

  • 김민석;박재한;정근호;이종균;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1077-1082
    • /
    • 2001
  • The most recent building trend is going large, high rise, high strength as overlarge project is developing in domestic construction business. Belite cement has properties like low heat, excellent long term strength, and durability without admixture(fly ash, silica fume). so, Belite cement is suitable for mass structure which is needed high strength, high fluidity and low heat property. This study is to examine the possibility of site adoption microwave-use early strength estimation method. Based on the existed study related the portland cement, the interrelation between Belite cement and microwave-use early strength estimation method is required. In this study, interrelation between mortar and Evaluating strength estimation method is investigated before the concrete experiment.

  • PDF

A experimental study on fluidity and strength propreties of cement using reject ash with high blaine value (가공된 잔사회를 사용한 시멘트 페이스트 유동성 및 강도특성에 관한 실험적 연구)

  • Hong, Man-Ki;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.301-302
    • /
    • 2010
  • The purpose of this study was to get basic information of using high blaine reject ash as a mineral admixtures in cement or concrete system. Compressive strength of mortar and rheological properties of slag cement with fly ash or high blaine reject ash($6,400cm^2/g$) were investigated.

  • PDF

An Experimental Study on the Early Strength Estimation of Belite Cement Concrete by Microwave Method (마이크로파 가열기법에 의한 저열 포틀랜드시멘트 콘크리트의 조기강도 추정에 관한 실험적 연구)

  • 이민경;황병준;전판근;박병근;김성식;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1041-1046
    • /
    • 2003
  • The most recent building trend is going large, high rise, high strength as overlarge project is developing in domestic construction business. Belite cement has properties like low heat, excellent long term strength, and durability without admixture (fly ash, silica fume). So, Belite cement is suitable for mass structure which is needed high strength, high fluidity and low heat property. This study is to examine the possibility of site adoption microwave-use early strength estimation method. Based on the existed study related the portland cement, the interrelation between Belite cement and microwave-use early strength estimation method is required.

  • PDF