DOI QR코드

DOI QR Code

Comparison Analysis of Fiber Distribution and Workability for Amorphous Steel Fiber Reinforced Concrete

비정질강섬유 보강콘크리트 작업성 및 섬유 분산성 비교분석

  • Kim, Byoung-Il (Advanced Building Research Division, Korea Institute of Construction Technology) ;
  • Lee, Sea-Hyun (Advanced Building Research Division, Korea Institute of Construction Technology)
  • Received : 2014.05.30
  • Accepted : 2014.08.01
  • Published : 2014.08.30

Abstract

The research was conducted to analyze workability and fiber distributions of amorphous steel fiber reinforced concrete by changing fiber length and fiber addition ratio. The inverted slump cone and vebe tests as well as slump test was performed to understand the fluidity of amorphous steel fibers which have quite different appearance compared to conventional steel fibers. Test results showed that thin plate type of amorphous steel fibers required different test approach to figure out workability since the reduction of workability from slump test was different that from inverted slump cone and vebe tests. In conclusion, fluidity of amorphous steel fibers to concrete was significantly degraded as fiber length and addition ratio increase. Also, fibers space in cement matrix was apparently reduced as the increase of fiber length and addition ratios without fiber balling.

본 논문에서는 비정질 강섬유의 길이 및 혼입률 변화에 의한 섬유보강콘크리트의 작업성과 섬유분산성에 대한 기초연구를 수행하였다. 일반적인 슬럼프시험 외에 역슬럼프 및 베베시험을 이용하여 일반 강섬유와는 외관 및 형상이 다른 비정질 감섬유의 유동성을 평가하였다. 실험결과, 얇은 판상형의 비정질강섬유의 작업성 평가를 위해서는 일반적인 슬럼프시험보다는 진동 하에서 수행된 역슬럼프 및 베베시험을 통한 유동성 평가가 바람직한 것으로 나타났다. 결론적으로 섬유의 혼입률 및 길이 증가는 콘크리트의 유동성을 현저히 감소시켰으며, 시멘트 메트릭스내에서 섬유간 간격 또한 감소시키는 결과를 보여주었다.

Keywords

References

  1. Yang, K .H., 2010 : Slump and Mechanical Properties of Hybrid Steel-PVA Fiber Reinforced Concrete, Journal of the Korea Concrete Institute, 22(5), pp. 651-658 https://doi.org/10.4334/JKCI.2010.22.5.651
  2. ACI Comittee 544, 1984 : Fiber Reinforced Concrete, ACI Special Publication SP-81, American Concrete Institute
  3. Shah, S. P., Ludirdja, D., Daniel, J. I., and Mobasher, B., 1988 : Toughness-Durability of Glass Fiber Reinforced Concrete System, ACI Materials Journal, 85(5), pp. 352-360
  4. Johnston, C. D., 1974 : Steel Fibre Reinforced Mortar and concrete-A Review of Mechanical Properties, Fiber Reinforced Concrete, SP-44, ACI, pp. 127-142
  5. Cha, S. W., Kim, K, H., Kim, S. W., Park, J. J., and Bae, S. G., 2010 : Models for hydration Heat Development and Mechanical Properties of Ultra High Peformance Concrete, Journal of the Korea Concrete Institute, 22(3), pp. 389-397 https://doi.org/10.4334/JKCI.2010.22.3.389
  6. Kang, S. T., and Ryu, G. S., 2011 : The Effect of Steel-Fiber Contents on the Compressive Stress-Strain Relation of Ultra High Performance Cementitious Composites (UHPCC), Journal of the Korea Concrete Institute, 23(1), pp. 67-75 https://doi.org/10.4334/JKCI.2011.23.1.067
  7. Jang, Y. I., Park, S. B., and Lee, B. J., 2010 : An Experimental Study on the Mechanical Properties of Ultra-High Strength Steel Fiber Reinforced Mortar Using Composite Slag Fine Aggregate, Journal of Korea Society of Waste Management, 27(3), pp. 204-211
  8. Kim, Y. Y., Kim, J. S., Kim, H. S., Ha, G. J., and Kim, J. K., 2005 : Mechanical Properties of an ECC(Engineered Cementitious Composite) Designed Based on Micromechanical Principle, Journal of the Korea Concrete Institute, 17(5), pp. 709-716 https://doi.org/10.4334/JKCI.2005.17.5.709
  9. Kim, Y. Y., 2003 : Mechanical and Repair Performance of Sprayed Ductile Fiber Reinforced Cementitous Composite(ECC), Journal of the Korea Concrete Institute, 15(3), pp. 462-469 https://doi.org/10.4334/JKCI.2003.15.3.462
  10. Mindess, S., Young, J. F., and Darwin, D., 2003 : Concrete, Prentice Hall, pp. 599-617
  11. ASTM C 995, 2004 : Standard Test Methods for Time of Flow of Fiber-Reinforced Concrete through Inverted Slump Cone, Annual Book of ASTM Standards
  12. BS 1881-104, 2004 : Testing concrete. Method for determination of vebe time, British Standards Institution
  13. Kim, B. I., 2010 : Transport Coefficients and Effect of Corrosion Reisistnace for SFRC, Journal of the Korea Concrete Institute, 22(6), pp. 867-873 https://doi.org/10.4334/JKCI.2010.22.6.867

Cited by

  1. Experimental Study on the Mechanical Properties of Amorphous Metallic Fiber-Reinforced Concrete vol.18, pp.3, 2018, https://doi.org/10.9798/KOSHAM.2018.18.3.1