References
- Yang, K .H., 2010 : Slump and Mechanical Properties of Hybrid Steel-PVA Fiber Reinforced Concrete, Journal of the Korea Concrete Institute, 22(5), pp. 651-658 https://doi.org/10.4334/JKCI.2010.22.5.651
- ACI Comittee 544, 1984 : Fiber Reinforced Concrete, ACI Special Publication SP-81, American Concrete Institute
- Shah, S. P., Ludirdja, D., Daniel, J. I., and Mobasher, B., 1988 : Toughness-Durability of Glass Fiber Reinforced Concrete System, ACI Materials Journal, 85(5), pp. 352-360
- Johnston, C. D., 1974 : Steel Fibre Reinforced Mortar and concrete-A Review of Mechanical Properties, Fiber Reinforced Concrete, SP-44, ACI, pp. 127-142
- Cha, S. W., Kim, K, H., Kim, S. W., Park, J. J., and Bae, S. G., 2010 : Models for hydration Heat Development and Mechanical Properties of Ultra High Peformance Concrete, Journal of the Korea Concrete Institute, 22(3), pp. 389-397 https://doi.org/10.4334/JKCI.2010.22.3.389
- Kang, S. T., and Ryu, G. S., 2011 : The Effect of Steel-Fiber Contents on the Compressive Stress-Strain Relation of Ultra High Performance Cementitious Composites (UHPCC), Journal of the Korea Concrete Institute, 23(1), pp. 67-75 https://doi.org/10.4334/JKCI.2011.23.1.067
- Jang, Y. I., Park, S. B., and Lee, B. J., 2010 : An Experimental Study on the Mechanical Properties of Ultra-High Strength Steel Fiber Reinforced Mortar Using Composite Slag Fine Aggregate, Journal of Korea Society of Waste Management, 27(3), pp. 204-211
- Kim, Y. Y., Kim, J. S., Kim, H. S., Ha, G. J., and Kim, J. K., 2005 : Mechanical Properties of an ECC(Engineered Cementitious Composite) Designed Based on Micromechanical Principle, Journal of the Korea Concrete Institute, 17(5), pp. 709-716 https://doi.org/10.4334/JKCI.2005.17.5.709
- Kim, Y. Y., 2003 : Mechanical and Repair Performance of Sprayed Ductile Fiber Reinforced Cementitous Composite(ECC), Journal of the Korea Concrete Institute, 15(3), pp. 462-469 https://doi.org/10.4334/JKCI.2003.15.3.462
- Mindess, S., Young, J. F., and Darwin, D., 2003 : Concrete, Prentice Hall, pp. 599-617
- ASTM C 995, 2004 : Standard Test Methods for Time of Flow of Fiber-Reinforced Concrete through Inverted Slump Cone, Annual Book of ASTM Standards
- BS 1881-104, 2004 : Testing concrete. Method for determination of vebe time, British Standards Institution
- Kim, B. I., 2010 : Transport Coefficients and Effect of Corrosion Reisistnace for SFRC, Journal of the Korea Concrete Institute, 22(6), pp. 867-873 https://doi.org/10.4334/JKCI.2010.22.6.867
Cited by
- Experimental Study on the Mechanical Properties of Amorphous Metallic Fiber-Reinforced Concrete vol.18, pp.3, 2018, https://doi.org/10.9798/KOSHAM.2018.18.3.1