• 제목/요약/키워드: Fluid limit

검색결과 223건 처리시간 0.031초

액셜 피스톤 펌프의 슈 홀드 스프링 설계 및 성능시험 (Design and Performance Test of the Shoe Holder Spring of the Axial Piston Pump)

  • 전영준;최진호;정희택;이상찬;김태일;김동우
    • 대한기계학회논문집A
    • /
    • 제26권11호
    • /
    • pp.2228-2236
    • /
    • 2002
  • The axial piston pump by which the mechanical energy is converted into hydraulic energy has been widely used in a press, a injection molding machine and construction equipments due to the high specific power compared to the electric power system. In this paper, the one-piece shoe holder spring of the axial piston pump to simplify its structure and reduce this manufacturing cost was designed and tested. The finite element analyses using the 3-D shell element and contact element were performed to determine the thickness, width and initial angle of the shoe holder spring. Also, the compressive tests of the shoe holder spring were performed and their results were compared with those of the finite element analysis. Also, the performance and endurance limit of axial piston pump with the shoe holder spring were tested and evaluated.

고 아음속 터빈 깃 주위의 열유동 및 내부 열전달에 관한 수치해석 연구 (A Numerical Investigation of External and Internal Heat Transfer in A High Subsonic in Turbine Cascade)

  • 김우진;김현식;곽재수;김학봉
    • 한국항공운항학회지
    • /
    • 제18권1호
    • /
    • pp.33-38
    • /
    • 2010
  • Developments of numerical methods are very important to design and analysis for a high subsonic turbine blade. In general, Analysis by experimental investigation has needed a lot of human resources and required time, indispensably, and equipments still have a limit to measure in conditions of high temperature. Rapid technological developments of CPU and integration level of memory make it possible to advance computation with almost exactly simulation so, recent developments of numerical methods are in spotlight. In the present study, the panel method, which is well-known as relatively simplified numerical method, and 2-dimensional ordinary differential Falkner-Skan equation were computed in order to analyze the outer flow, and FVM-based solid heat transfer equation, was also computed to forecast the temperature distribution of the airfoil and the turbine blade. Unstructured grid was constructed in the turbine blade, which has double cooling holes, in order to analyze the internal heat transfer. Cooling fluid was assumed as fully-developed turbulent flow and that circulated in cooling holes.

Exposure Assessment to Suggest the Cause of Sinusitis Developed in Grinding Operations Utilizing Soluble Metalworking Fluids

  • Park, Dong-Uk;Choi, Byung-Soon;Kim, Shin-Bum;Kwag, Hyun-Seok
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.326-329
    • /
    • 2005
  • A worker who grinded the inner parts of camshafts for automobile engines using water-soluble metalworking fluid (MWF) for 14 years was diagnosed with sinusitis. We postulated that the outbreak of sinusitis could be associated with exposure to microbes contaminated in water-soluble MWF during the grinding operation. To suggest responsible agents for this outbreak, quantitative exposure assessment for chemical and biological agents and prevalence of work-related respiratory symptoms by questionnaire were studied. The exposure ranges of MWF mist (0.59 $mg/m^3$to 2.12 $mg/m^3$) measured during grinding exceeded 0.5 $mg/m^3$ of the recommended exposure limit (REL). Grinder's exposures to bacteria, fungi and endotoxins were also generally higher than not only the proposed standards, but also those reported by several studies to identify the cause of respiratory effects. Statistical test indicated that the prevalence rate of reported symptoms related to nasal cavities showed no significant differences among the operations. Evaluation on grinding operation characteristics and quantitative exposure assessment indicated that repeated exposure to MWF mist including microbes contaminated from the use of water-soluble MWF may cause respiratory diseases like sinusitis or at least increase susceptibility to the development of sinusitis

  • PDF

두 대의 펌프가 병렬로 설치된 장치의 유량 특성 (FLOW CHARACTERISTICS OF A SYSTEM WHICH HAS TWO PARALLEL PUMPS)

  • 박정근;박종호;박용철
    • 한국전산유체공학회지
    • /
    • 제17권4호
    • /
    • pp.1-8
    • /
    • 2012
  • During a reactor normal operation, two parallel 50% capacity cooling pumps circulate primary coolant to remove the fission reaction heat of the reactor through heat exchangers cold by a cooling tower. When one pump is failure, the other pump shall continuously circulate the coolant to remove the residual heat generated by the fuels loaded in the reactor after reactor shutdown. It is necessary to estimate how much flow rate will be supplied to remove the residual heat. We carried out a flow network analysis for the parallel primary pumps based on the piping network of the primary cooling system in HANARO. As result, it is estimated that the flow rate of one pump increased about 1.33 times the rated flow of one pump and was maintained within the limit of the cavitation critical flow.

정체 유동장에 떠있는 난류 예혼합 화염의 일차 모멘트 닫힘 모사 (First Moment Closure Simulation of Floating Turbulent Premixed Flames in Stagnation Flows)

  • 이은주;허강열
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제20회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.122-132
    • /
    • 2000
  • Computational fluid dynamic simulation is performed for the floating turbulent premixed flames stabilized in stagnation flows of Cho et al. [1] and Cheng and Shepherd [2]. They are both in the wrinkled flamelet regime far from the extinction limit with $u'/S^{0}_{L}$ less than unity. The turbulent flux is given in the first moment closure as a sum of the classical gradient flux due to turbulent motions and the countergradient flux due to thermal expansion. The parameter $N_{B}'s$ are greater than unity with the countergradient flux dominant over the gradient flux. The countergradient flux is assumed to be zero in $\bar{c}<0.05$. The flame surface density is modeled as a symmetric parabolic function with respect to $\bar{c}$. The product of the maximum flame surface density and the mean stretch factor is considered as a tuning constant to match the flame location. Good agreement is achieved with the measured $\tilde{w}$ and $\bar{c}$ profiles along the axis in both flames.

  • PDF

전산유체역학을 위한 일반 곡률좌표계에서 운동량 방정식의 종속변수 선정에 관한 연구 (A Study on the Selection of Dependent Variables of Momentum Equations in the General Curvilinear Coordinate System for Computational Fluid Dynamics)

  • 김원갑;최영돈
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.198-209
    • /
    • 1999
  • This study reports the selection of dependent variables for momentum equations in general curvilinear coordinates. Catesian, covariant and contravariant velocity components were examined for the dependent variable. The focus of present study is confined to staggered grid system Each dependent variable selected for momentum equations are tested for several flow fields. Results show that the selection of Cartesian and covariant velocity components intrinsically can not satisfy mass conservation of control volume unless additional converting processes ore used. Also, Cartesian component can only be used for the flow field in which main-flow direction does not change significantly. Convergence rate for the selection of covariant velocity component decreases quickly as with the increase of non-orthogonality of grid system. But the selection of contravariant velocity component reduces the total mass residual of discretized equations rapidly to the limit of machine accuracy and the solutions are insensitive to the main-flow direction.

유동과 전기장 내에서의 액체입자의 거동과 전기장이 입자의 산란에 미치는 영향에 관한 수치적 연구 (Numerical Evaluation of charged Liquid Particle′s Behavior in Fluid Flow and Electric Field and The Electric Effect on the Particle Dispersion)

  • 김형민
    • 대한기계학회논문집B
    • /
    • 제26권4호
    • /
    • pp.570-577
    • /
    • 2002
  • Charged liquid particle's behavior in electric and flow field was simulated to define the effect of electric field on the contact area and its dispersion. For the simulation of flow and electric field finite volume method was applied. To find out the particle's moving path in that field lagrangian equation of motion was solved by Runge-Kutta methods. We assumed that the particle was charged 10% of Rayleigh limit while the particle passing through the electrode and the particle does not have an effect on the electric field. In case of 30[Kv] of voltage charging the particles injected from the central 60% of the nozzle injection area adhere to the grounded moving plate and no dispersion occurred. Increasing the charged voltage to 40[Kv], it brought about the same phenomena as that of 30[Kv] charging except the dispersion. Voltage increasing from 30[Kv] to 40 [Kv] caused higher Coulomb force acts on the particle and it made the particle dispersion.

대형배관 내부식 코팅공정의 온도 균일성 향상을 위한 와류날개 형상 연구 (A Study on the Temperature Uniformity for the Anti-Corrosion Coating Process of Large-Sized Water Pipes)

  • 박재현;박희성;김수태;강경무
    • 한국기계가공학회지
    • /
    • 제15권6호
    • /
    • pp.35-40
    • /
    • 2016
  • In this study, the thermal and fluid dynamic characteristics for the coating process of large-sized water pipes was studied by heating the inside of a pipe directly with a gas burner. Heat and flow analyses were performed on large pipes with various inlet shapes. Using large pipes for coating was shown to be the proper shape for heating large pipes uniformly. This type has a screw with a diameter of 200 mm installed at the inlet to provide a rotational motion to the heating air. The rotational motion resulted in a uniform temperature distribution that ranged from $289.1^{\circ}C$ to $352.1^{\circ}C$ The optimized geometric configuration of the inlet of the pipe successfully and uniformly enhanced the thermal characteristics of the devised temperature limit.

Experimental Study on the Thermal Performance of a Small-scale Loop Heat Pipe with Polypropylene Wick

  • Boo Joon Hong;Chung Won Bok
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.1052-1061
    • /
    • 2005
  • A small-scale loop heat pipe (LHP) with polypropylene wick was fabricated and tested for investigation of its thermal performance. The container and tubing of the system were made of stainless steel and several working fluids were tested including methanol, ethanol, and acetone. The heating area was $35\;mm\;{\times}\;35\;mm$ and nine axial grooves were provided in the evaporator to provide vapor passages. The pore size of the polypropylene wick inside the evaporator was varied from $0.5\; {\mu}m\;to\;25\;{\mu}m.$ The inner diameter of liquid and vapor transport lines were 2.0 mm and 4.0 mm, respectively and the length of which were 0.5 m. The size of condenser was $40\;mm\;(W)\;{\times}\;50\;mm\;(L)$ in which ten coolant paths were provided. Start-up characteristics as well as steady-state performance was analyzed and discussed. The minimum thermal load of $10\;W\;(0.8\;W\;/cm^{2})$ and maximum thermal load of $80\;W\;(6.5\;W\;/cm^{2})$ were achieved using methanol as working fluid with the condenser temperature of $20^{\circ}C$ with horizontal position.

대류가열 비정상 접촉융해에 대한 해석해 (An Analytical Solution for the Unsteady Close-Contact Melting by Convective Heating)

  • 유호선
    • 대한기계학회논문집B
    • /
    • 제24권3호
    • /
    • pp.450-458
    • /
    • 2000
  • This study deals with the unsteady close-contact melting of solid blocks on a flat surface subject to convective heating. Normalizing the model equations in reference to the steady solution successfully leads them to cover constant heat flux and isothermal limits at small and large extremes of the Biot number, respectively. The resulting equations admit a compactly expressed analytical solution, which includes the previous solutions as a subset. Based on the steady solution, the characteristics of close-contact melting can be categorized into constant heat flux, transition, and isothermal regimes, the boundaries of which appear to be nearly independent of the contact force. The unsteady solutions corresponding to Biot numbers in the transition regime show intermediate behaviors between those of the two limits. With a proper approximation, the present solution procedure can cope with the case of variable fluid temperature and heat transfer coefficient. Regardless of imposed conditions, the mean normalized Nusselt number during the unsteady process asymptotically approaches to a constant value as the Biot number comes close to each limit.