• 제목/요약/키워드: Fluid Measure

검색결과 473건 처리시간 0.028초

소형태양수구내(小型太陽水構內) 중간경계면(中間境界面)에서 수력학적(水力學的) 안정(安定)에 관(關)한 각종(各種) 지배변수(支配變數)의 비교(比較) (A Comparison of Various Governing Parameters on Hydrodynamic Stability in Interface on Small Solar Pond)

  • 박이동
    • 태양에너지
    • /
    • 제5권2호
    • /
    • pp.11-19
    • /
    • 1985
  • In this paper, the interface stability not to occur mixing and entrainment between the adjacent layers has been studied in the case of the selective withdrawal of a stratum and the injection in stratified fluid formed by the density difference in a small solar pond. There are stability parameter, Richardson number, Rayleigh number and Froude number as the parameters governing stability in order to measure the interface stability on the stratified fluid. The model which could measure the interface stability on the stratified fluid was the small solar pond composed by 1 meters wide, 2 meters high, and 5 meters long. In order to measure the interface stability on the stratified fluid at the inlet port, the middle section and the outlet port, Richardson number, Rayleigh number, and Froude number involved in the parameters governing the stability were calculated by means of the data resulted from the test of the study on hydrodynamic stability between the convective and nonconvective layers in that solar pond. Richardson number written by the ratio of inertia force to buoyancy force can be used in order to measure the stability on the stratified fluid related to the buoyancy force generated from the injection of fluid. Rayleigh number written by the product of Grashof number by Prandtl number can be used in order to measure the stability of the fluid related to the heat flux and diffusivity of viscosity. Froude number written by the ratio of gravity force to inertia force can be used in order to measure the stability of the nonhomogeneous fluid related to the density difference. As the result of calculating the parameters governing stability, the interface stability on the stratified fluid couldn't be identified below the 70cm height from the bottom of the solar pond, but it could be identified above the 70cm height from it at the inlet port, the middle section and the outlet port. When compared with such the three parameters as Richardson number, Rayleigh number, Froude number, the calculated result was in accord with them at inlet port, the middle section and the outlet port. Henceforth, it is learned that even though any of the three parameters is used for the purpose of measuring the interface stability on the stratified fluid, the result will be the same with them. It is concluded that all the use of Richardson number, Rayleigh number, and Froude number, is desirable and infallible to measure the interface stability on the stratified fluid in the case of considering the exist of the fluid flow and the heat flux like the model of the solar pond.

  • PDF

Measurement of Sound Speed Following the Fluid Temperature Using Acoustic Inspection Device

  • Jeon, E.S.;Kim, W.T.;Kim, I.S.;Park, H.
    • 비파괴검사학회지
    • /
    • 제30권3호
    • /
    • pp.207-211
    • /
    • 2010
  • In this paper, the fluid AID(acoustic inspection device) was developed to measure SOS(speed of sound) since fluids used in most of industrial fields have different properties and its equipment is highly expensive. From AID developed, it is intended to get potentially the capability to distinguish the kind of fluid using the measurement by the SOS at various fields. In order to measure the sound speed of specific fluids, the measurement system and ultrasonic sensors are composed. The fluid used in the experimental work are soybean oil, glycerin, diesel oil and the error of time difference due to the container wall is extracted for preliminary experiment. As results, the variations of sound speed according to the temperature change of target fluid were analyzed and the polynomial equations were proposed.

ISO 10767-1에 기초한 유압 펌프의 유량 맥동 측정 및 정밀도 평가 (Measurement of Hydraulic Pump Flow Ripple Characteristics Based on the ISO 10767-1 and the Evaluation of the Measuring Accuracy)

  • 김지웅;강만곤;이일영
    • 유공압시스템학회논문집
    • /
    • 제4권3호
    • /
    • pp.22-27
    • /
    • 2007
  • The source flow ripple and the source impedance in hydraulic pump are characteristic values showing fluid-borne vibration characteristics decisively. We cannot measure these two characteristic values directly, but can measure them by some indirect methods. One representative indirect measuring method is ISO 10767-1. The authors constructed a hardware and a software for the measuring method based on ISO 10767-1. Through the error evaluation of the measured results, accuracy of the measuring method using ISO 10767-1 was examined in detail.

  • PDF

수분 섭취량 측정법에 관한 연구 (A Study on Fluid Intake Measurements)

  • 이창관;김유경;서명화;이경미;이주은
    • 성인간호학회지
    • /
    • 제25권5호
    • /
    • pp.567-573
    • /
    • 2013
  • Purpose: The purpose of this study was to compared two methods for measuring fluid intake and to assess the most effective method. Methods: Data from 44 hospitalized patients with chronic kidney disease was analyzed. Two methods were used. The liquid method is to measure the daily intake of water in the form of pure water or some other beverage and IV fluid, the liquid-solid method is to measure the daily intake of water which enters by the oral route and IV fluid. Results: The daily intake of fluid was 1483.10mL and 2245.99mL respectively. The fluid output was 1883.72 mL. The Intra-Class Correlation (ICC) between the liquid method and the liquid-solid method and fluid output was 0.64 and 0.69, respectively. The correlation between differences of fluid in two methods and body weight change was r=.47 (p<.001) and r=.56 (p<.001), respectively. Conclusion: The results of this study suggest that there are no difference between the two measuring methods as to reflecting the most close value to fluid output. And the difference between intake and output by two methods is correlated with body weight change. Therefore, it can be suggested that the either method could be useful as patients' fluid intake measurement.

Two-Fluid Model을 이용한 교통신호제어시스템 개선에 따른 거시적 교통류 변화 분석 (Analysis of the Macroscopic Traffic Flow Changes using the Two-Fluid Model by the Improvements of the Traffic Signal Control System)

  • 정영제;김영찬;김대호
    • 대한교통학회지
    • /
    • 제27권1호
    • /
    • pp.27-34
    • /
    • 2009
  • 도로교통망의 시스템변화에 대한 효과분석의 일환으로 1979년 Herman이 제시한 Two-Fluid Model을 적용하여 거시적인 교통류 변화특성을 분석하였으며, 이를 통해 도로시설의 운영개선 효과를 정량적으로 확인하였다. 본 연구에서는 일반국도 3호선 의정부 전체 구간의 약 8km, 총 31개 신호교차로를 분석 대상으로 하며, TSIS CORSIM 및 Run Time Extension을 이용한 미시적 시뮬레이션 분석으로 현황 및 개선 대안에 대한 개별차량의 주행정보를 추출하였다. Two-Fluid Model의 파라메타 산출결과 현황 대비 신호제어시스템 개선 시 네트워크의 서비스 질을 의미하는 단위거리 당 평균최소통행시간(Tm)은 약 35% 감소하였으며, 네트워크 수요증가에 대한 저항성을 의미하는 파라메타 n은 약 28%의 향상된 결과를 나타내었다. 국도 축을 대상으로 하는 시뮬레이션 기반의 자료 수집으로 인해 제한된 연구결과이나 Two-Fluid Model이 신호 최적화 및 연동형 반감응제어의 적용 등 신호제어시스템 개선에 대한 우수한 거시적 효과평가 지표로 활용되어 질 수 있음을 확인하였다.

A Calculation for the Viscosity of Fluid at the Critical Point

  • Kim, Won-Soo;Chair, Tong-Seek
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권11호
    • /
    • pp.1524-1526
    • /
    • 2002
  • It is very difficult to measure the fluid viscosity at the critical point, there are seldom found experimental values of fluid viscosity at the critical point. Few theories can explain the critical viscosity quantitatively. A theory of viscosity previously proposed by authors10 is applied to the fluid at the critical point. This theory can be simplified as a simple form with no adjustable parameters, allowing for easy calculation. Viscosities at the critical point for some substances have been calculated, and calculated results are satisfactory when compared with the observed values.

극한지에서의 유체기계를 위한 플랜트 설비구조물의 비파괴 건전도 평가 (Strength Evaluation of the Plant Facility for Fluid Machinery Using Schmidt Hammer in Cold Regions)

  • 홍승서;김영석
    • 한국유체기계학회 논문집
    • /
    • 제19권3호
    • /
    • pp.25-28
    • /
    • 2016
  • The Schmidt hammer test is one of the best nondestructive tests to measure the strength without breaking structures, which has been used to measure the strength of concrete structures in a simple way at construction sites. However, the future research is needed to apply Schmidt hammer in cold regions. This study is intended to investigate the correlation between unconfined compression test result of the oil storage facilities foundation taken at the King Sejong Antarctic Station and Schmidt hammer test result at the sample-taking site. Also, the equation for uniaxial compression strength using Schmidt hammer rebound value is proposed.

전자기력에 의한 자성유체의 2차원 자유표면 형상 제어에 관한 연구 (Study on the two-dimensional Formation Control of Free Surface of Magnetic Fluid by Electromagnetic Force)

  • 안창호;지병걸;이은준;박명관
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.979-982
    • /
    • 2003
  • In this study, because of change in electromagnetic force, deformation of the free surface motion of a magnetic fluid is changed. Deformation of the free surface motion of a magnetic fluid for the change in electromagnetic force is discussed and carried out theoretically and experimentally on the basis of Rosensweig Ferrohydrodynamic Bernoulli Equation. Objective of this study explicates free surface motion by electromagnetic force and planes to designed controller. To control free surface of magnetic fluid, it embody designed two-dimensional free surface form of magnetic fluid. By using this characteristics, they applied to oscillator for surface control, flow control, boundary layer control. Strength of magnetic field and height of free surface of magnetic fluid measure as a hall-effect sensor. As performing height control of magnetic fluid, the result will be presented possibility of free surface deformation control.

  • PDF

미소입자영상유속계를 이용한 굴절률이 다른 두 유체 유동 측정 (Micro PIV Measurement of Two-Fluid Flow with Different Refraction Indices)

  • 김병재;유임정;성형진
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.107-114
    • /
    • 2003
  • The influence of property difference in refraction index on micro PIV measurement of two-fluid flow in a microchannel was analyzed. The difference of measurement planes in two fluids would bring misunderstanding of the physics. The objective-imaging system for two-fluid flow measurement was presented, and the condition for measurement of valid velocity profile across two-fluid interface was derived. A micro PIV experimental system was set up to measure two-fluid flow inside a Y-shape microchannel. Under the conditions, three cases of two-fluid flow of glycerol solutions at different concentration (${\phi}$), e.g., (${\phi}=0\;and\;{\phi}=0.2,\;{\phi}=0.1\;and\;{\phi}=0.5,\;{\phi}=0\;and\;{\phi}=0.6$, were measured. Close agreement of experimental and numerical results was found.

  • PDF