DOI QR코드

DOI QR Code

Strength Evaluation of the Plant Facility for Fluid Machinery Using Schmidt Hammer in Cold Regions

극한지에서의 유체기계를 위한 플랜트 설비구조물의 비파괴 건전도 평가

  • Hong, Seung-Seo (Korea Institute of Civil Engineering and Building Technology) ;
  • Kim, YoungSeok (Korea Institute of Civil Engineering and Building Technology)
  • 홍승서 (한국건설기술연구원 지반연구소) ;
  • 김영석 (한국건설기술연구원 지반연구소)
  • Received : 2016.03.29
  • Accepted : 2016.04.30
  • Published : 2016.06.01

Abstract

The Schmidt hammer test is one of the best nondestructive tests to measure the strength without breaking structures, which has been used to measure the strength of concrete structures in a simple way at construction sites. However, the future research is needed to apply Schmidt hammer in cold regions. This study is intended to investigate the correlation between unconfined compression test result of the oil storage facilities foundation taken at the King Sejong Antarctic Station and Schmidt hammer test result at the sample-taking site. Also, the equation for uniaxial compression strength using Schmidt hammer rebound value is proposed.

Keywords

References

  1. 연길환, 윤석천, 송인춘, 1987, "반발도법과 초음파속도법의 복합법에 의한 콘크리트 압축강도의 추정," 대한건축학회지, Vol. 3, No. 3, pp. 161-169.
  2. 권영웅, 박송철, 김민수, 2006, "슈미트 해머 시험에 의한 고강도 콘크리트의 강도 추정식," 한국콘크리트학회논문집, Vol. 18, No. 3, pp. 389-396.
  3. 김영석, 이종섭, 홍승서, 2012, "남극 세종기지 방문기," 한국지반공학회지, Vol. 28, pp. 8-19.
  4. Hudson, J. A. and Harrison, J. P., 2000, Engineering Rock Mechanics - an introduction to the principles, Pergamon, pp. 177-181.