• Title/Summary/Keyword: Flowing

Search Result 2,384, Processing Time 0.031 seconds

Flowing Ability and Mechanical Properties of Polypropylene Fiber Reinforced High Performance Concrete

  • Kim, Young-Ik;Sung, Chan-Yong
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.27-37
    • /
    • 2003
  • This study was performed to examine the flowing ability and filling ability of polypropylene fiber reinforced high performance concrete. The slump flow was decreased with increasing the polypropylene fiber content, rapidly. At the box-type filling ability, the difference of box height was increased with increasing the fiber content and the box-type passing ability was closed in fiber content 1 %. The final flowing distance of L-type was decreased with increasing the fiber content. Also, it was decreased above 0.75% of polypropylene fiber content, rapidly. The filling ability of L-type was badly showed above polypropylene fiber content 0.75%. Also, the compressive strength was decreased with increasing the fiber content, but the flexural strength was shown higher than that of the concrete without fiber. At the impact resistance, drop numbers for reaching in final fracture were increased with increasing the fiber content. Also, the drop numbers for reaching initial fracture of 1mm were increased with increasing the fiber content. At the acid resistance, the percent of original mass was decreased with increasing the fiber content.

Flowing and Strength Properties of Ternary System Inorganic Composite According to the Change of W/B and Addition Ratio of Na2SiO3 (3성분계 무기결합재의 W/B 및 규산나트륨 첨가율 변화에 따른 유동 및 강도특성)

  • Bae, Sang-Woo;Moon, Ji-Hwan;Lee, Yun-Seong;Lee, Kang-Pil;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.49-50
    • /
    • 2011
  • This study tried to utilize basic data for developing the cement substitute material through ternary system inorganic composite properties of flowing and strength. W/B and addition ratio of Na2SiO3 have been changed in ternary system inorganic composite combined blast furnace slag, red mud and fly ash. As to the experimental result inorganic composite, the flowing and intensity improvement effect was showed to be bigger than W/B according to the addition ratio change of the Na2SiO3. When particularly the Na2SiO3 addition ratio was 6%, the rapid flowing and strength improvement effect was confirmed.

  • PDF

In-Situ Application of High-Strength Antiwashout Underwater Concrete

  • Moon Han-Young;Song Yong-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.283-291
    • /
    • 2004
  • Recently, the construction of underwater structures has been gradually increased, but underwater concrete got some problems of quality deterioration and water contamination around cast-in-situ of construction. In addition, massive underwater structures such as LNG tank, underwater concrete structures of large and continuous high- strength subterranean wall under water are being demanded lower heat of hydration. In this paper, the mechanical properties of high-strength antiwashout underwater concrete (HAWC) containing with two kinds of mineral admixtures respectively were investigated. On the basis of these results, the pH value and suspended solids of HAWC manufactured in the mock-up test were 10.0$\Box$11.0 and 51 mg/${\iota}$ at 30 minutes later, respectively, initial and final setting time were about 30,37 hours, and the slump flow was 530$\pm$20Tm. In the placement at a speed of $27 m^3/hr$, there was no large difference in flowing velocity with or without reinforcing bar, and flowing slope was maintained at horizontal level. Compressive strength and elastic modulus of the cored specimen somewhat decreased as flowing distance was far; however, those of central area showed the highest value.

The Heat Transfer and Pressure drop Characteristics of R7l8 in Small Diameter Tubes (세관내 액단상의 열전달과 압력강하에 관한 연구)

  • 김세웅;홍진우;손창효;노건상;오후규
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.28-35
    • /
    • 2001
  • The heat transfer and pressure drop characteristics of R718 flowing in smooth horizontal copper tubes with inner diameter of 3.36 mm, 5.35 mm, 6.54 mm and 8.12 mm were investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. Experiments were peformed for the flowing range of variables : Reynolds number (1000 to 20000), mass flow rate of brine (450 kg/h) and refrigerant temperature (5$0^{\circ}C$). The main results were summarized as follows : (1) The heat transfer coefficient of 3.36 mm ID was about 10% to 30% higher than that of 5.35 mm, 6.54 mm and 8.12 mm ID, and the heat transfer coefficients for small diameter. tubes are about 20% to 27% higher than these predicted by Gnielinski. The new correlation is proposed to predict the experimental data. (2) As a result of comparison with correlation prosed by Blasius. the deviation of the experimental data slightly increased as the tube diameter decreased. (3) The ratio of heat transfer to friction factor (j/f) correlated by all experimental data increased as the tube diameter decreased.

  • PDF

Daily Living Service Flowing in Skilled Nursing Facilities for the Elderly -Focused on Dining and Bathing Area- (노인전문요양시설의 일상생활 지원 서비스 작업흐름 분석 -식사 및 목욕공간을 중심으로 -)

  • Lee Min Ah
    • Journal of Families and Better Life
    • /
    • v.22 no.6 s.72
    • /
    • pp.1-11
    • /
    • 2004
  • The purpose of this study was to provide basic information about efficient space use in the dining and bathing area through the analysis of service flowing. Four researchers observed the service flowing and the using behavior at those areas. The results of the study were as follows: Dining service was proceeded as resident moving, waiting, meal serving, dining, moving and arranging in order. The waiting stage was one of the problematic processes since the staffs made the residents wait to) long at a fixed position. The program right before the meal serving will be helpful for reducing tediousness of the elderly residents. Another problem was that the area was not big enough for the meal sowing. The legal regulation Is needed to prescnbe for the size of dining area per resident. The flowing of bathing service was proceeded as staff preparation, moving, waiting, undressing, bathing, drying, dressing, moving and arranging in order. There were more problems in the dressing area than in the bathing area. The elderly with stretcher or wheelchairs had difficulty in entering the narrow doorway. The dressing area was so crowded with the staffs, undressed elderly, dressed elderly, and other laundries. The division of dressing and undressing area is required to avoid the confusion of the users in the area.

Field Application of Concrete Using Drying Shrinkage-Reducing Superplasticizer (건조수축 저감형 유동화제를 사용한 콘크리트의 현장적용)

  • Shin, Jae-Kyung;Oh, Chi-Hyun;Choi, Jin-Man;Lee, Seong-Yeun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.13-16
    • /
    • 2006
  • This study investigates filed application in Daebul Free Trade Zone of a flowing method using drying shrinkage-reducing superplasticizer(SRS) and an insulating curing method using double bubble sheets. Test showed that fresh concrete satisfied target slump and air content. A structure adding SRS significantly decreased the total bleeding capacity and accelerated the setting time. As for the crack occurrence, the structure applying the flowing method and double bubble sheets simultaneously exhibited the most favorable crack endurance, while conventional concrete showed more than 1mm size of crack in overall, and a structure applying only the flowing method partially presented micro crack. For the area proportion of crack occurrence, the structure using the double bubble sheets indicated 9.8%, while others applying flowing method was 28%, compared with 100% of conventional one. Standard curing specimens had about $3{\sim}6%$ higher compressive strength than that of specimens cured at adjacent field construction. In addition, using SRS improved about $5{\sim}7MPa$, than that of conventional concrete at 91 days elapse.

  • PDF

A Novel Non-contact Measurement Method for the Detection of Current Flowing Through Concealed Conductors

  • Yang, Fan;Liu, Kai;Zhu, Liwei;Hu, Jiayuan;Wang, Xiaoyu;Shen, Xiaoming;Luo, Hanwu;Ammad, Jadoon
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • In order to detect the current flowing through concealed conductor, this paper proposes a new method based on derivative method. Firstly, this paper analyzes the main peak characteristic of the derivative function of magnetic field generated by a current-carrying conductor, and a relationship between the current flowing through the conductor and the main peak of the derivative function is obtained and applied to calculate the current. Then, the method is applied to detect the conductor current flowing through grounding grids of substations. Finally, the numerical experimental and field experiment verified the feasibility and accuracy of the method, and the computing results show that the method can effectively measure the conductor current of grounding grids with low error, and the error is within 5 %.

Evaluation of Mixing Conditions for the Production of Optimized High Flowing Concrete

  • Kim, Sang-Chel
    • KCI Concrete Journal
    • /
    • v.11 no.3
    • /
    • pp.79-88
    • /
    • 1999
  • Most difficulties of inducing high fluidity on the concrete mixing design with a strength range of 210 to 240kg/$\textrm{cm}^2$ result from the segregation of aggregates due to the shortage of cementitious binders. To solve the problem, this study concentrated on finding the optimized amount of binder material which does not affect the concrete strength and is also economical. Also there were studies on the use of intermediate sized aggregates to avoid the gap-grading between coarse and fine aggregates so that the material segregation in high flowing concrete was and minimalized the fluidity and penetration capacity of the reinforcing bars was enhanced. Throughout the parametric study with respect to water/binder ratio. superplasticizer. replaceable mineral admixture, the size of coarse aggregate and mixing methods, the effect of each constituent on the characteristics of high flowing concrete could be observed. As a result or partially using stone powder or an intermediate class of aggregate (max. diameter 13mm) . it was fund that the fluidity of concrete significantly increased without material segregation and any change of compressive strengths. It was also proved in this study that proper mixing time and speed are significant factors influence the performence of high flowing concrete.

  • PDF

An Experimental Study on the Strength Properties of Flowing Lightweight Aggregate Concrete with Age (재령에 따른 고유동 경량골재콘크리트의 강도특성에 관한 실험적 연구)

  • Jeon, Hyun-Kyu;Yoo, Taek-Dong;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.4
    • /
    • pp.186-193
    • /
    • 1998
  • The purpose of this research is to seek properties of flowing light-weight aggregate concrete and possibility of application. The experimental analysis results by using light-weight aggregate and industrial waste such flyash, furnace slag are as follow. 1) The research shows that flowing light-weight aggregate concrete of slump 23~27cm, slump flow 58~69 cm is possible, but material segregation is appeared above slump 26.5cm and slump flow 65 cm. 2) If mixing ratio of flyash is increase, strength deterioration is about 25 % in early age. It showed that effectiveness of long time strength improvement because strength manifestation ratio is above 95% in a long term. 3) This research showed possibility of substitution of blast furnace slag because strength deterioration by using mixing of furnace slag was appeared small deterioration range as below 10 %. 4) Each experimental compressive strength ratios were 77 %(1st week), 86 %(2nd week), 109 %(8th week), 115 %(13th week), 125 % (26th week) on the basis of 28 days. If mixing ratio of flyash is increase, long term strength increase ratio is improved.

  • PDF

Research on Protection Method for Ground Electrode of DC Systems from Corrosion (직류 접지극의 전식보호 방법 연구)

  • Jeong, Woo-Yong;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.90-95
    • /
    • 2021
  • In contrast to AC grounding systems, the ground electrode in DC systems continuously maintains positive or negative polarity. Ground electrodes with (+) polarity proceeds by oxidation reaction. Thus, the DC current should flow opposite to the polarity of the leakage current flowing through the (+) ground electrode by using a compensation electrode, and the current flowing through the (+) ground electrode can be 0A. However, according to protecting the (+) ground electrode, the compensation electrode corrodes and gets damaged. Thus, the (+) ground electrode must be protected from corrosion, and the service life of the compensation electrode must be extended. As an alternative, the average value of the current flowing through the compensation electrode should be equal with the value of the leakage current flowing through the (+) ground electrode by using the square waveform. Throughout the experiment, the degree of corrosion on the compensation electrode is analyzed by the frequency of the compensation electrode for a certain time. In the experiment, the frequencies of the square waveform are considered for 0.1, 1, 10, 20, 50, 100 Hz, and 1 kHz. Through experiments and analysis, the optimal frequency for reducing the electrolytic damage of the (+) electrode and compensation electrode in an LVDC grounding environment is determined.