• Title/Summary/Keyword: Flow-delivery

Search Result 389, Processing Time 0.025 seconds

Theory and Prediction of Turbulent Transition

  • Dou, Hua-Shu;Khoo, Boo-Cheong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.114-132
    • /
    • 2011
  • We have proposed a new approach based on energy gradient concept for the study of flow instability and turbulent transition in parallel flows in our previous works. It was shown that the disturbance amplitude required for turbulent transition is inversely proportional to Re, which is in agreement with the experiments for imposed transverse disturbance. In present study, the energy gradient theory is extended to the generalized curved flows which have much application in turbomachinery and other fluid delivery devices. Within the frame of the new theory, basic theorems for flow instability in general cases are provided in details. Examples of applications of the theory are given from our previous studies which show comparison of the theory with available experimental data. It is shown that excellent agreement has been achieved for several configurations. Finally, various prediction methods for turbulent transition are reviewed and commented.

Research on scheduling and optimization under uncertain conditions in panel block production line in shipbuilding

  • Wang, Chong;Mao, Puxiu;Mao, Yunsheng;Shin, Jong Gye
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.398-408
    • /
    • 2016
  • Based on non-completely hybrid flow line scheduling of panel block in shipbuilding, several uncertain factors influencing the problem were analyzed in a real environment, and a nonlinear integer programming model was built for each sub-scheduling problem. To narrow the difference between theory and application, rolling horizon and rescheduling methods are proposed. Moreover, with respect to the uncertainty of processing time, arriving time and due time, we take the minimizing of the early and delayed delivery costs as the objective, and establish an evaluation with a global penalty function. Finally, numerical experiments and a simulation analysis were undertaken to demonstrate the effectiveness of the model and algorithm.

Precision Injection Molding Analysis of Plastic Part with Rectangular Micro-Holes (미세 사각홀을 갖는 플라스틱 부품의 정밀사출성형해석)

  • Lee S. H.;Jung T. S.;Heo Y. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.436-441
    • /
    • 2005
  • In this study, precision injection molding analysis for BGA connector fabrication was performed. A BGA connector model with rectangular micro-holes were introduced to investigate the effect of mirco patterns on the injection molding process. Dual domain(2.5D) mesh and full 3D mesh for BGA connector model were prepared to perform precision injection molding analysis. To verify the Present analysis, experiments of injection molding were performed based on the results of the analysis. It was shown that the type of mesh has a significant effect on the flow pattern of BGA connector

  • PDF

-Machining Route Selection with the Shop Flow Information Using Genetic Algorithm- (작업장 특성을 고려한 가공경로선정 문제의 유전알고리즘 접근)

  • 이규용;문치웅;김재균
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.54
    • /
    • pp.13-26
    • /
    • 2000
  • Machining route selection to produce parts should be based on shop flow information because of input data at scheduling tasks and is one of the main problem in process planning. This paper addresses the problem of machining route selection in multi-stage process with machine group included a similar function. The model proposed is formulated as 0-1 integer programing considering the relation of parts and machine table size, avaliable time of each machine for planning period, and delivery date. The objective of the model is to minimize the sum of processing, transportation, and setup time for all parts. Genetic algorithm approach is developed to solve this model. The efficiency of the approach is examined in comparison with the method of branch and bound technique for the same problem. Also, this paper is to solve large problem scale and provide it if the multiple machining routes are existed an optimal solution.

  • PDF

Performance evaluation study of a commercially available smart patient-controlled analgesia pump with the microbalance method and an infusion analyzer

  • Park, Jinsoo;Jung, Bongsu
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.2
    • /
    • pp.129-143
    • /
    • 2022
  • Background: Patient-controlled analgesia (PCA) has been widely used as an effective medical treatment for pain and for postoperative analgesia. However, improper dose errors in intravenous (IV) administration of narcotic analgesics from a PCA infusion pump can cause patient harm. Furthermore, opioid overdose is considered one of the highest risk factors for patients receiving pain medications. Therefore, accurate delivery of opioid analgesics is a critical function of PCA infusion pumps. Methods: We designed a microbalance method that consisted of a closed acrylic chamber containing a layer and an oil layer with an electronic balance. A commercially available infusion analyzer (IDA-5, Fluke Co., Everett, WA, USA) was used to measure the accuracy of the infusion flow rate from a commercially available smart PCA infusion pump (PS-1000, UNIMEDICS, Co., Ltd., Seoul, Korea) and compared with the results of the microbalance method. We evaluated the uncertainty of the flow rate measurement using the ISO guide (GUM:1995 part3). The battery life, delay time of the occlusion alarm, and bolus function of the PCA pump were also tested. Results: The microbalance method was good in the short-term 2 h measurement, and IDA-5 was good in the long-term 24 h measurement. The two measurement systems can complement each other in the case of the measurement time. Regarding battery performance, PS-1000 lasted approximately 5 days in a 1 ml/hr flow rate condition without recharging the battery. The occlusion pressure alarm delays of PS-1000 satisfied the conventional alarm threshold of occlusion pressure (300-800 mmHg). Average accuracy bolus volume was measured as 63%, 95%, and 98.5% with 0.1 ml, 1 ml, and 2 ml bolus volume presets, respectively. A 1 ml/hr flow rate measurement was evaluated as 2.08% of expanded uncertainty, with a 95% confidence level. Conclusion: PS-1000 showed a flow accuracy to be within the infusion pump standard, which is ± 5% of flow accuracy. Occlusion alarm of PS-1000 was quickly transmitted, resulting in better safety for patients receiving IV infusion of opioids. PS-1000 is sufficient for a portable smart PCA infusion pump.

Selection of Priority Management Target Tributary for Effective Watershed Management in Nam-River Mid-watershed (남강 중권역의 효율적인 유역관리를 위한 중점관리 대상지류 선정)

  • Jung, Kang-Young;Kim, Gyeong-Hoon;Lee, Jae-Woon;Lee, In Jung;Yoon, Jong-Su;Lee, Kyung-Lak;Im, Tae-Hyo
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.514-522
    • /
    • 2013
  • The major 24 tributaries in Nam-River mid-watershed were monitored for discharge and water quality in order to understand the characteristics of the watershed and to select the tributary catchment for improving water quality. According to the analytical results of discharge and water quality monitoring data of 24 tributaries, the mean value of discharge below $0.1m^3/s$ was 62.5% among the monitored tributaries and it mostly exceeded the water quality standards of Nam-river mid-watershed ($BOD_5$ = 3 mg/L, T-P = 0.1 mg/L over). According to the stream grouping method and the water quality delivery load density ($kg/day/km^2$) based on the results of tributary discharge and water quality monitoring, the tributary watersheds for improving the water quality were selected. In the Nam-River mid-watershed, tributaries in the GaJwaCheon, HaChonCheon catchment (Group D, $BOD_5$ = 3 mg/L over) and in the UirYeongCheon, SeokGyoCheon catchment (Group A, T-P = 0.1 mg/L over), which have a small flow (and/or large flow) and a high concentrations of water pollutants. The various water quality improving scheme for tributaries, in accordance with the reduction of potential point source pollution by living sewage and livestock wastewater, should be established and implemented.

An Analysis of the Changes in the Financial Performance of Teaching Hospitals after the Implementation of the Separation Policy of Prescription and Drug Dispensing: A case of the teaching hospitals in D area (의약분업이후 대학병원 경영수지변화 비교 분석 (D지역 대학병원 사례를 중심으로))

  • Eun, Jong-Seong;Youn, Kyung-Il
    • Korea Journal of Hospital Management
    • /
    • v.8 no.1
    • /
    • pp.64-80
    • /
    • 2003
  • The separation policy of prescription and drug dispensing which has been implemented since the 1st of July, 2000, has brought about great changes in patients flow within the healthcare delivery system. The changes in the patients flow, in turn, resulted in the change in the distribution of financial resources among the participating entities in the healthcare delivery system: pharmacies, clinics, small hospitals, general hospitals, and teaching hospitals. The purpose of this study is to shed some light in the change in the financial performance of teaching hospitals under the separation policy that has created environmental changes such as the decrease in the number of out patients visits, the increase in the capital expenditures, the rapid increase in labor costs and so on. For the purpose, this study has compared and analyzed the balance sheets, the income statements and other operational data of three teaching hospitals located in D area. The data include two periods: before(year 1999) and after(year 2001) the implementation of the separation policy. The analysis was conducted with an emphasis on the changes in the financial ratios such as liquidity, turnover ratio, performance ratio. and capitalization ratio. The results show that the financial performances of the hospitals under study were weaker than before the implementation of the separation policy, and that, while the operating expenses have increased remarkably, there was no tendency to corresponding increase in revenue. And the result of analysis of other operational indicators also show that the performance of the hospitals is getting worse. Based on the results, this study has suggested the directions of the healthcare policies. This study suggests to improve the current model of separation of prescription and drug dispensing, to grant subsidies for the training of residents in teaching hospitals, and to lower the rate of patients' out of porket payment in teaching hospitals.

  • PDF

Delivered Pollutant Loads of Point and Nonpoint Source on the Upper Watershed of Lake Paldang - Case Study of the Watershed of Namhan River and Gyeongan Stream (팔당호 상류유역의 점·비점오염원 유달부하 특성 - 남한강·경안천 수계를 대상으로)

  • Park, Ji Hyoung;Kong, Dong Soo;Min, Kyung Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.750-757
    • /
    • 2008
  • This study is conducted to characterize and evaluate delivered pollutant loads of point and nonpoint source on the upper watershed of lake paldang. The study area consists of 12 watersheds in Namhan-river and Kyungahcheon, which are approximately 80% of total area of Namhan-river and Kyungahcheon. Based on daily delivered loads from watersheds, 61% of $BOD_5$, 81% of T-N and 70% of T-P were from nonpoint sources, suggesting that delivered loads of nonpoint pollutants be crucial to water quality. On the other hand, 78% of $BOD_5$, 92% of T-N and 87% of T-P as delivered load were from nonpoint sources in an upper watershed of Namhan-river, while 48% of $BOD_5$, 70% of T-N and 57% of T-P as delivered load were from nonpoint sources in a lower watershed of Namhan-river, suggesting higher dependency of point sources than upper watershed of Namhan-river. In the characteristic of delivered loading pollutants from point and nonpoint pollution sources, delivered load of nonpoint pollutants differed significantly by seasonal flow, and as though discharged load of point pollutants were yearly uniform, delivered load of point pollutants was found to be flow-dependent because its delivery ratio was changed.

Modelling of Sediment Transportation and Deposition in GIS (GIS를 이용한 토사이송 및 퇴적분포 예측기법 개발)

  • Son, Kwang-Ik
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.3 s.152
    • /
    • pp.223-233
    • /
    • 2005
  • In this study, a two-dimensional model for identifying areas of erosion and deposition over a basin was developed based on the mass balance principle in a distributed model. The program consists of three steps: (a) estimation of soil erosion; (b) determination of flow amount and direction; and (c) estimation of mass balance. Soil erosion was estimated with USLE. A single-direction (SF) and a multi-direction flow algorithm (MF) were applied to estimate slope length (L). The Maximum Downhill Slope Method (MDS) and the Neighborhood Method (NBH) were used to estimate the slope degree (S). Sediment transport resulting from eroded soil was estimated using Ferro's (1998) and Swift's (2000) sediment delivery ratio (DR). The model was validated by comparing the predicted sediment yields for three basins with measured data. The developed algorithm showed that Ferro's DR method combined with the MDS and MF produced the best agreement with the dredging records of three agricultural reservoir basins in Korea.

Deriving Mobile Robot Delivery Service Security Requirements Using STRIDE Threat Modeling (STRIDE 위협모델링을 활용한 이동로봇 배송 서비스 보안 요구사항 도출)

  • Ji-Yong Choi;Jae-Dong Jang;Sang-Joon Lee
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.34 no.5
    • /
    • pp.927-947
    • /
    • 2024
  • Due to the global low birth rate and aging population, there is a growing interest in utilizing robot technology as a solution to address labor shortages. Specifically, mobile robots, which are growing rapidly, have become intelligent enough to recognize their environment and avoid obstacles to carry out tasks. However, the integration of IT technology into these robots has led to an increase in potential security vulnerabilities, and security research has been conducted to prepare countermeasures. However, research to examine the security threats of mobile robots in general is insufficient. To enhance the overall security of robot systems, it is imperative to systematically identify security threats starting from the design phase. In this paper, we identify security threats within the mobile robot delivery service environment using a structured approach that involves Data Flow Diagram and STRIDE threat modeling. Additionally, we visualize vulnerabilities and attack techniques through Attack Tree based on the Attack Library, and a Check List has finally been created to derive security requirements. We have been conducted this study with the hope that the results derived from this study will be utilized in establishing guidelines and policies related to robot security and contribute to the establishment of a safe robot foundation.