• 제목/요약/키워드: Flow sensors

검색결과 472건 처리시간 0.031초

Reed Switch 센서를 이용한 원격 검침용 상수도 계량기에서 Chattering 오차 감소 방안 연구 (Reduction Chattering Error of Reed Switch Sensor for Remote Measurement of Water Meter)

  • ;권종원;박용만;구상준;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.377-379
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors used for automatic remote measurement of water supply system, a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used in measurement application by detecting the rotational or translational displacement. To apply for flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just installed simply on the mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor, two steel leaf springs make mechanical contact and apart as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But it occurs data difference or errors by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing car near to the switch sensor installed location. In order to reduce chattering error, most system uses just software methods for example using filter and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical hysteresis characteristics.

  • PDF

연속흐름 중합효소연쇄반응칩 제작을 위한 인듐 산화막 전극의 특성분석 (Characteristics of Indium-Tin-Oxide Electrode for Continuous-flow PCR Chip)

  • 정승룡;김준혁;이인제;강치중;김용상
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.561-565
    • /
    • 2007
  • We propose glass and PDMS (polydimethylsiloxane) chips for DNA amplification with continuous-flow PCR (polymerase chain reaction). The PDMS microchannel was fabricated using a negative molding method for sample injection. Three heaters and sensors of ITO (indium-tin-oxide) thin films were fabricated on glass chip. ITO heaters and sensors were calibrated accurately for the temperature control of the liquid flow. ITO heater generated stable heat versus applied power. ITO sensor resistance was changed linearly versus temperature increase as a RTD (resistance temperature detector) sensor. As a result, we enable precision temperature control of continuous-flow PCR chip. Using the continuous-flow PCR chip DNA plasmid pKS-GFP 720 bp was successfully amplified.

축류 홴의 익단누설와류 및 후류에서 유량에 따른 변동속도의 주파수 특성 (Frequency Characteristics of Fluctuating Velocity According to Flow Rates in a Tip Leakage Vortex and a Wake Flow in an Axial Flow Fan)

  • 장춘만;김광용;후카노토오루
    • 대한기계학회논문집B
    • /
    • 제28권2호
    • /
    • pp.181-188
    • /
    • 2004
  • The frequency characteristics in an axial flow fan operating at a design and three off-design operating conditions have been investigated by measuring the velocity fluctuation of a tip leakage vortex and a wake flow. Two hot-wire probe sensors rotating with the fan rotor. a fixed and a moving ones, were introduced to obtain a cross-correlation coefficient between two sensors as well as the fluctuating velocity. The results show that the spectral peaks due to the fluctuating velocity near the rotor tip are mainly observed in the reverse flow region of higher flow rates than those in the peak pressure operating condition. However, no peak frequency presents near the rotor tip for near stall condition. Detailed wake flow just downstream of the rotor blade was also measured by the rotating hot-wire sensor. The peak frequency of a high velocity fluctuation due to Karman vortex shedding in the wake region is mainly observed at the higher flow rate condition than that in the design point.

분체 밀도와 속도를 이용한 유량검출기의 개발 (The Development of Flow-Meter System Using the Granule Flow Density And Velocity)

  • 김재현;황건호;이용식;정성원
    • 조명전기설비학회논문지
    • /
    • 제23권5호
    • /
    • pp.9-17
    • /
    • 2009
  • 본 논문은 발전소 보일러 및 제철소 고로의 미분탄 연소방식에 적용이 가능한 유량계 개발에 관한 연구로서 분체의 밀도와 속도로 미분탄의 유량을 측정하는 시스템을 개발하였다. 관에 흐르는 미분탄의 밀도는 관의 표면에 전극을 설치하여 기준극과 측정극사이의 커패시터를 이용하여 측정한다. 속도는 일정 거리에 두 개의 전극을 설치하고 이 전극으로부터 두 개의 파형을 교차 상관관계 알고리즘을 이용하여 계산하였다. 분체의 유량을 측정된 밀도와 속도에 의하여 계산한다. 이 시스템에 설치된 로드셀에 의한 데이터와 개발한 유량 측정 시스템의 데이터를 비교하여 신뢰성을 확인하였다.

고응답 열식 질량공기유량센서의 제작 및 열거동 특성 (Micro-Fabrication and Thermal Characteristics of a Thermal Mass Air Flow Sensor for Real-time Applications)

  • 박병규;이준식
    • 대한기계학회논문집B
    • /
    • 제32권7호
    • /
    • pp.542-548
    • /
    • 2008
  • A thermal mass air flow sensor (MAFS), which consists of a micro-heater and thermo-resistive sensors on the silicon-nitride ($Si_3N_4$) thin membrane structure, is micro-fabricated by MEMS processes. Two thermo-resistive temperature sensors are located at $100{\mu}m$ upstream and downstream from the micro-heater respectively. The thermal characteristics are measured to find the best measurement indicator. The micro-heater is operated under constant power condition, and four flow indicators are investigated. The normalized temperature indicator shows good physical meaning and is easy to use in practice. It is found that the configurations and heating power of thermal-resistive elements are the dominant factors to determine the range of the flow measurement in the MAFS with higher sensitivity and accuracy.

Design and Fabrication of Six-Degree of Freedom Piezoresistive Turbulent Water Flow Sensor

  • Dao, Dzung Viet;Toriyama, Toshiyuki;Wells, John;Sugiyama, Susumu
    • 센서학회지
    • /
    • 제11권4호
    • /
    • pp.191-199
    • /
    • 2002
  • This paper presents the design concept, theoretical investigation, and fabrication of a six-degree of freedom (6-DOF) turbulent flow micro sensor utilizing the piezoresistive effect in silicon. Unlike other flow sensors, which typically measure just one component of wall shear stress, the proposed sensor can independently detect six components of force and moment on a test particle in a turbulent flow. By combining conventional and four-terminal piezoresistors in Si (111), and arranging them suitably on the sensing area, the total number of piezoresistors used in this sensing chip is only eighteen, much fewer than the forty eight piezoresistors of the prior art piezoresistive 6-DOF force sensor.

Fabrication and Characteristics of Micro-Electro-Mechanical-System-Based Gas Flow Sensor

  • Choi, Ju-Chan;Lee, June-Kyoo;Kong, Seong-Ho
    • 센서학회지
    • /
    • 제20권6호
    • /
    • pp.363-367
    • /
    • 2011
  • This paper proposes a highly-sensitive gas flow sensor with a simple structure. The sensor is composed of a micro-heater for heating the gas medium and a pair of temperature sensors for detecting temperature differences due to gas flow in a sealed chamber on one axis. Operation of the gas flow sensor depends on the transfer of heat through the air medium. The proposed gas flow sensor has the capability to measure gas flow rates <5 $cm^3$/min with a resolution of approximately 0.01 $cm^3$/min. Furthermore, this paper reports some additional experiment results, including the sensitivity of the proposed gas flow sensor as a function of operating current and the flow of different types of gas(oxygen, carbon dioxide, and nitrogen). The fabrication process of the proposed sensor is very simple, making it a good candidate for mass production.

The Deposition and Characteristics of Ni Thin Films according to Annealing Conditions for the Application of Thermal Flow Sensors

  • Noh, Sang-Soo;Lee, Eung-Ahn;Lee, Sung-Il;Jang, Wen-Teng
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권4호
    • /
    • pp.161-165
    • /
    • 2007
  • In this work, Ni thin films with different thickness from $1,523{\AA}\;to\;9,827{\AA}$ were deposited for the application of micro thermal flow sensors by a magnetron sputtering and oxidized through annealing at $450^{\circ}C$ with increasing annealing time. The initial variation of resistivity decreased radically with increasing films thickness, then gradually stabilizes as the thickness increases. The resistivity of Ni thin films with $3,075{\AA}$ increased suddenly with increasing annealing time at $450{\circ}C$, then gradually stabilizes as the thickness increases after the annealing time 9 h. In case of $3,075{\AA}\;and\;9,827{\AA}$ films, the average of TCR values, measured for the operating temperature range of $0^{\circ}C\;to\;180^{\circ}C$, were $2,413.1ppm/^{\circ}C\;and\;4,438.5ppm/^{\circ}C$, respectively. Because of their high resistivity and very linear TCR, Ni oxide thin films are superior to pure Ni and Pt thin films for flow and temperature sensor applications.

수중 유속 및 유향의 동시 측정을 위한 이미지 분석 기술에 관한 연구 (Image Analysis for the Simultaneous Measurement of Underwater Flow Velocity and Direction)

  • 서동민;오상우;변성훈
    • 센서학회지
    • /
    • 제32권5호
    • /
    • pp.307-312
    • /
    • 2023
  • To measure the flow velocity and direction in the near field of an unmanned underwater vehicle, an optical measurement unit containing an image sensor and a phosphor-integrated pillar that mimics the neuromasts of a fish was constructed. To analyze pillar movement, which changes with fluid flow, fluorescence image analysis was conducted. To analyze the flow velocity, mean force analysis, which could determine the relationship between the light intensity of a fluorescence image and an external force, and length-force analysis, which could determine the distance between the center points of two fluorescence images, were employed. Additionally, angle analysis that can determine the angles at which pixels of a digital image change was selected to analyze the direction of fluid flow. The flow velocity analysis results showed a high correlation of 0.977 between the external force and the light intensity of the fluorescence image, and in the case of direction analysis, omnidirectional movement could be analyzed. Through this study, we confirmed the effectiveness of optical flow sensors equipped with phosphor-integrated pillars.

Infusion Pump용 Drop Sensor 개발에 관한 연구

  • 이종실;권장우;이응혁;박정선;구자일;홍승홍
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.18-21
    • /
    • 1995
  • When we inject drugstuffs to a patient for a long time, it is important to control proper injection amount and flow rate. Since inproper injection amount and a flow rate would cause bad a recovery a patient, the relience of sensors which detect injection amount is an important factor for whole injection systems' performance. In this research, we've compared the suitability of three sensors for injection pump monitoring system. The three types of sensors, piezo film sensor, photo transistor made up with three transmitting photodiodes and receving photodiode, and photo array, were selected for comparing. Using suggested data processing technique and photo amy sensors, we could minimize the effect of interference, disturbance, illumanation change, and sensitivity change caused by sensor's position. According to the experiments, the photo amy showed the higher reliance than any other the three types of sensors. The developed systems could be the foundation of beginning home production of infusion pump system and available for the base model of whole monitoring and control systems.

  • PDF