• 제목/요약/키워드: Flow line

Search Result 2,348, Processing Time 0.029 seconds

A Simulation Study on the Application of Cellular Manufacturing System in the Automated Welding Line Producing Excavator-parts (굴삭기 부품 용접 자동화라인의 셀생산방식 적용을 위한 시뮬레이션 연구)

  • Kim, Hye Jeong;Lee, Seung Woo;Moon, Dug Hee
    • Journal of the Korea Society for Simulation
    • /
    • v.22 no.2
    • /
    • pp.93-100
    • /
    • 2013
  • Mixed model production system means that various products are manufactured alternately in a line, and it has become a popular system in the era of multi-product small-quantity production. However, in the mixed model production system using flow line, the unbalance among stations is not inevitable because the workloads of stations cannot be the same. Thus, flow line system has been replaced to cellular manufacturing system for reducing the loss of waiting due to the unbalance of stations. In this paper, we introduce the simulation case study of an automated welding line which produces the parts of excavator. The factory has considered replacing the mixed model flow line to the cellular manufacturing system based on FMC concept. The increase of production quantity is estimated about 26.7%, and the lead time is reduced more than 55%. Furthermore sensitivity analyses are conducted considering the changes of product-mix.

A method for the determination of transient flow rates from pressure measurements (압력측정을 이용한 과도기유량의 결정방법에 관한 연구)

  • 이성래
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.724-729
    • /
    • 1992
  • A transient hydraulic flow rate computation scheme is described here so that the transient hydraulic flow rate can be determined using the dynamic pressure measurements at the ends of a straight flowline with a dynamic, model of the hydraulic line. Simulation results indicate that the method is relatively robust to realistic levels of uncertainties in the fluid properties.

  • PDF

A study on the GUI of load flow of power systemconsidering function of searching solutions (해 탐색기능을 고려한 전력조류의 GUI에 관한 연구)

  • Lee, Hee-Yeong
    • Journal of the Korea Computer Industry Society
    • /
    • v.5 no.9
    • /
    • pp.851-858
    • /
    • 2004
  • This paper presents improved teaching and learning GUI for easily analysis tool of load flow of power system with database function for searching solution. In this paper includes not only contingency analysis function but also searching function of conditional solution sets from database of solution for various load levels. The GUI is friendly for study for power system operation and control because picture provide a better visualizing of relationshipsbetween input parameters and effects than a tabula type result. This GUI enables topologyand the output data of load flow for line outages to be shown on same picture page. Userscan input the system data for power flow on the the picture and can easily see the theresult diagram of bus voltage, bus power, line flow. It is also observe the effects of different types of variation of tap, shunt capacitor, loads level, line outages. Proposed GUI has been studied on the Ward-Hale 6-Bus system.

  • PDF

Cause Analysis of Flow Accelerated Corrosion and Erosion-Corrosion Cases in Korea Nuclear Power Plants

  • Lee, Y.S.;Lee, S.H.;Hwang, K.M.
    • Corrosion Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.182-188
    • /
    • 2016
  • Significant piping wall thinning caused by Flow-Accelerated Corrosion (FAC) and Erosion-Corrosion (EC) continues to occur, even after the Mihama Power Station unit 3 secondary pipe rupture in 2004, in which workers were seriously injured or died. Nuclear power plants in many countries have experienced FAC and EC-related cases in steam cycle piping systems. Korea has also experienced piping wall thinning cases including thinning in the downstream straight pipe of a check valve in a feedwater pump line, the downstream elbow of a control valve in a feedwater flow control line, and failure of the straight pipe downstream of an orifice in an auxiliary steam return line. Cause analyses were performed by reviewing thickness data using Ultrasonic Techniques (UT) and, Scanning Electron Microscope (SEM) images for the failed pipe, and numerical simulation results for FAC and EC cases in Korea Nuclear Power Plants. It was concluded that the main cause of wall thinning for the downstream pipe of a check valve is FAC caused by water vortex flow due to the internal flow shape of a check valve, the main cause of wall thinning for the downstream elbow of a control valve is FAC caused by a thickness difference with the upstream pipe, and the main cause of wall thinning for the downstream pipe of an orifice is FAC and EC caused by liquid droplets and vortex flow. In order to investigate more cases, additional analyses were performed with the review of a lot of thickness data for inspected pipes. The results showed that pipe wall thinning was also affected by the operating condition of upstream equipment. Management of FAC and EC based on these cases will focus on the downstream piping of abnormal or unusual operated equipment.

CFD Analysis on Discharge Passage Flow of Hydrogen Reciprocating Compressor (왕복동식 수소압축기의 토출구 유동에 관한 CFD해석)

  • Lee, Gyeong-Hwan;Rahman, Mohammad-Shiddiqur;Chung, Han-Shik;Jung, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.561-566
    • /
    • 2008
  • The reciprocating compressor is widely used in the industry field, because it has simple principle and high efficiency. In this work, in order to improve design of discharge passage line in hydrogen compression system Numerical analysis was conducted. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including velocity, pressure and turbulence kinetic energy distribution of hydrogen gas going out from the cylinder to discharge-path line are presented in this paper. Discharge-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows velocity, pressure and turbulent kinetic energy are not distributed uniformly along the passage of the Hydrogen system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement might be done.

  • PDF

The Optimal Operating Points of Multiple UPFCs for Enhancing Power System Security Level (전력시스템 안전도 향상을 위한 다기 UPFC의 최적 운전점 결정)

  • 임정욱;문승일
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.8
    • /
    • pp.388-394
    • /
    • 2001
  • This paper presents how to determine the optimal operating points of Unified Power Flow controllers (UPFC) the line flow control of which can enhance system security level. In order to analyze the effect of these devices on the power system, the decoupled model has been employed as a mathematical model of UPFC for power flow analysis. The security index that indicates the level of congestion of transmission line has been proposed and minimized by iterative method. The sensitivity of objective function for control variables of and UPFC has been derived, and it represents the change in the security index for a given set of changes in real power outputs of UPFC. The proposed algorithm with sensitivity analysis gives the optimal set of operating points of multiple UPECs that reduces the index or increases the security margin and Marquart method has been adopted as an optimization method because of stable convergence. The algorithm is verified by the 10-unit 39-bus New England system that includes multiple FACTS devices. The simulation results show that the power flow congestion can be relieved in normal state and the security margin can be guaranteed even in a fault condition by the cooperative operation of multiple UPECs.

  • PDF

Modeling, Simulation and Fault Diagnosis of IPFC using PEMFC for High Power Applications

  • Darly, S.S.;Vanaja Ranjan, P.;Justus Rabi, B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.760-765
    • /
    • 2013
  • An Interline Power Flow Controller (IPFC) is a converter based controller which compensates and balance the power flow among multi-lines within the same corridor of the multi-line subsystem. The Interline Power Flow Controller consists of a voltage source converter based Flexible AC Transmission System (FACTS) controller for series compensation. The reactive voltage injected by individual Voltage Source Converter (VSC) can be controlled to regulate active power flow in the respective line in which one VSC regulates the DC voltage, the other one controls the reactive power flows in the lines by injecting series active voltage. In this paper, a circuit model for IPFC is developed and simulation of interline power flow controller is done using the proposed circuit model. Simulation is done using MATLAB Simulink and PSPICE. The results obtained by MATLAB are compared with the results obtained by PSPICE and compared with theoretical values.

Increase of Cell Concentration by the Automatic Analysis and Addition of glucose with an On-line Flow Injection Analysis System int he Cultivation of Saccharomyces cerevisiae Using a Korean Paper Digestion Wastewater (한지자숙폐액을 이용한 Saccharomyces cerevisiae의 배양에서 온-라인 FIA시스템에 의한 Glucose의 자동분석 및 첨가에 의한 증균)

  • 이형춘
    • KSBB Journal
    • /
    • v.15 no.4
    • /
    • pp.388-392
    • /
    • 2000
  • An on-line glucose flow injection analysis system was developed and used for the automatic analysis and addition of glucose in the cultivationof a Saccharomyces cerevisiae in a korean paper digestion wastewater in order to increase the cell concentration. The system was composed of a ceramic sampler a sampling valve an injection valve an immobilized glucose oxidase column a debbble a flow cell with platinum electrodes a potentiostat a computer and interface system and tubing pumps. The glucose concentration of the wastewater medium was mainitained at the low concentration of $176{\pm}31 mg/L$ with the on-line FIA system and by adding glucose and $>(NH_4)_2S0_4$ the cell concentration as total cell count can be increased by 3.1times.

  • PDF

무기담채를 이용한 폐수처리

  • Cha, Wol-Seok;Gwon, Gyu-Hyeok;Choe, Hyeong-Il;Jeong, Gyeong-Hun;Lee, Dong-Byeong;Jeong, Gil-Rok
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.343-347
    • /
    • 2003
  • Power of loess ball on nitrogen and phosphorous removal in wastewater treatment were investigated. flow line A ( anaerobic${\rightarrow}$oxic${\rightarrow}$anoxic(organic source methanol)${\rightarrow}$p-absorption) showed the results of T-P 0.5, T-N 1.0, and COD 10ppm bellow, and flow line B ( oxic${\rightarrow}$anoxic, organic source: methanol${\rightarrow}$p-absorption) showed the results of T-P 0.3, T-N 5.0, and COD 15 ppm bellow. flow line C ( anaerobic${\rightarrow}$oxic${\rightarrow}$anoxic, organic source: wastewater ${\rightarrow}$ p-absorption) showed the results of T-P 0.6, T-N 10, and COD 15 ppm bellow, and flow line D ( oxic${\rightarrow}$anoxic, organic source: methanol${\rightarrow}$p-absorption) showed the results of T-P 1, T-N 8m, and COD 20 ppm bellow. So the results of these experiments showed the probability of loess ball in wastewater treatment.

  • PDF