• 제목/요약/키워드: Flow data acquisition

검색결과 183건 처리시간 0.025초

가스 유량 계측 및 제어 시스템 연구 (Development of a Gas Flow Measurement and Control System)

  • 전학진;양종화
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.255-259
    • /
    • 1996
  • This paper describes a system for measurement and control of a gas flow. In order to measure the flux of gas and control a vavle according to flux, this system was developed. This system is implemented on the personal computer and its environment is developed tool called TMS. This system includes a main program and Tele-Metering Unit for transmitting correcting flow value based on temperature and pressure in flow computer and AD converter for transmitting instantaneous flow rate, temperature and pressure as interface part of personal computer. This system was made by Visual C++ program. Using this system, inspected data for the recognition of transmitting flow value are generated on the screen, file and printer. The activity, reliability of this system was verified on Daegu-Citygas that aids the system for the acquisition of inspected data by realtime application.

  • PDF

상태추정을 이용한 고 신뢰도 측정데이터 확보방안 연구 (Preparation of Reliable Measurement Data by Using State Estimation)

  • 김홍래
    • 한국산학기술학회논문지
    • /
    • 제8권5호
    • /
    • pp.1020-1025
    • /
    • 2007
  • 전력시스템을 안정적이고 경제적으로 운영하기 위하여 EMS(energy management system)와 SCADA(supervisory control and data acquisition) 시스템이 사용되고 있다. EMS 내의 조류계산, 상정고장해석, 안전도해석과 같은 다양한 기능들의 신뢰성을 높이기 위해서는 정확한 데이터의 확보가 필수적이다. EMS 내에서 상태추정이 이와 같은 역할을 수행할 수 있으며, 본 논문에서는 정확한 상태추정을 위한 가관측성 해석 및 불량데이터 처리 프로그램을 개발하였다. 기본적인 알고리즘을 설명하고 사례연구를 통해 제안된 기법의 타당성을 검증하였다.

  • PDF

고형물 이송을 위한 유압구동 선형 피스톤 펌프의 개발 (Development of the Linear Piston Pump Driven by the Hydraulic Power for the Solid Transferring)

  • 김봉환;안국찬;정성원;김영훈
    • 한국기계가공학회지
    • /
    • 제8권3호
    • /
    • pp.82-89
    • /
    • 2009
  • The purpose of this study is to investigate the actual field application of the linear piston pump for the solid transferring driven by the hydraulic power unit. In this paper, the numerical analysis and performance evaluating experiments were performed. CFX program has been used to obtain the solutions for the problems of three-dimensional, turbulent water flow in the linear piston pump. The velocity and the pressure distributions are obtained using the turbulent $k-\varepsilon$ model. To evaluate the performance of the linear piston pump, the performance test stand and data acquisition system were manufactured. The numerical predictions agree favorably with experimental results within 7% error. Speed of the piston which is satisfied the flow rate 3,000l/min which considers from basic design became 0.33m/s. This paper could be applied to the design of the linear piston pump for the fish transferring.

  • PDF

성별, 쇼핑동기, 플로우 경험이 쇼핑행동에 미치는 영향 (Effects of gender, shopping motivation, flow experience on shopping behavior)

  • 최자영;이규혜
    • 디지털융복합연구
    • /
    • 제10권5호
    • /
    • pp.53-66
    • /
    • 2012
  • 본 연구에서는 소비자들의 쇼핑행동 이해에 필요한 쇼핑 동기, 쇼핑 플로우 경험, 그리고 구매 간의 관계에서 구조적 관계를 파악하기 위해 이에 대한 인과구조 모형을 개발하여 그 모형에 대한 실증 분석을 하였다. 또한 쇼핑 동기는 성별의 차이가 크다는 여러 이론 및 연구를 바탕으로 성별이 쇼핑동기에 미치는 영향을 검증하였고, 성별과 쇼핑동기간에 차이가 나타났으며 5개의 쇼핑동기 중 제품획득 쇼핑동기를 제외한 기분전환, 아이디어 추구, 사회적 상호작용, 자아만족, 가치추구 쇼핑동기가 플로우 경험에 영향을 미치는 것으로 나타났다. 또한 플로우 경험이 높을수록 구매를 하는 것으로 나타났다. 특히 본 연구는 플로우의 선행변수로써 과거의 선행연구에서 강조하였던 모험심 및 능력이 아닌 동기가 쇼핑플로우 경험에 중요한 영향을 미친다는 시사점을 제공하고, 쇼핑 플로우가 구매 행동에 영향을 미친다는 점을 실증분석을 하였다는데 의의를 갖는다.

하천 유량.수질변화 특성을 고려한 수질오염총량관리 기준유량 조건에 관한 연구 (A Study on the Suggestions for Standard Flow Conditions considering the Variation of Stream Flow and Water Quality for the Management of Total Maximum Daily Loads)

  • 박준대;오승영;최윤호
    • 한국물환경학회지
    • /
    • 제28권3호
    • /
    • pp.426-435
    • /
    • 2012
  • The variation of stream flow is the one of the most important factors which influence on that of water quality in the unit watershed. The target water quality goal is established and permissible load is allotted in the base of the standard flow condition along with its water quality for the management of Total Maximum Daily Loads (TMDLs). A standard flow selected could cause problems in the load allotment if it was not properly arranged. This study reviewed the acquisition of water quality data, the self-variation and the retainability in water quality on the specific flow conditions. This study also proposed the median and the adjusted average flow condition out of general flow conditions as alternative standard flow conditions. It is considered that the alternatives can make the water quality data easily acquired and the water quality representativeness more enhanced on the standard flow conditions.

격납건물 국부누설률시험 표준절차 개발 (Development of Standard Procedures for Local Leakage Rate Testing of Containment Vessel)

  • 문용식;김창수
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.42-47
    • /
    • 2012
  • The containment local leakage rate testing in nuclear power plants is performed in accordance with ANSI/ANS 56.8-1994 in Korea. Two methods, the make-up flow rate and the pressure decay, are used for local leakage rate testing. Though ANSI/ANS 56.8-1994 does not define clearly the minimum test duration for the make-up flow rate method, it requires obtaining the data after reaching the stable condition. Thus the prerequisite stable condition for data acquisition and the testing time is differently applied to each NPPs. Therefore, this study presents a standardized test procedure for data stabilization and testing time through experiments to improve the test reliability.

Experimental Study on the Mean Flow Characteristics of Forward-Curved Centrifugal Fans

  • Kwon, Eui-Yong;Cho, Nam-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1728-1738
    • /
    • 2001
  • Measurements have been made in an automotive HVAC b1ower for two different centrifugal fans. This work is directed at improving the performance of a conventional forward-curved centrifugal fan for a given small blower casing. Mean velocities and pressure have been measured using a miniature five-hole probe and a pressure scanning unit connected to an online data acquisition system. First, we obtained the fan performance versus flow rates showing a significant attenuation of unstable nature achieved with the new fan rotor in the surging operation range. Second, aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage for different fan operating conditions. The measurements stowed that performance coefficients are strongly influenced by flow characteristics at the throat region. The main flow features ware common in both fans, but improved performance is achieved with tole new fan rotor, particularly in lower flow rate legions. Based on the measured results, design improvements were carried out in an acceptable operation range, which gave considerable insight into what features of flow behavior ware most important.

  • PDF

자유수면에 세워진 원주 주위의 유동특성을 이용한 자유표면 유속계의 개발 (Development of surface-flow velocimetry based on flow characteristics around a cylinder piercing a water free surface)

  • 김인철;조명종;김상준;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.607-612
    • /
    • 2001
  • Based on the flow characteristics around a piercing cylinder, a free surface-flow velocitmetry which can be used in extremely harsh environment such as molten steel flow was developed. The velocimetry is consisted of finite length cylinder, load detecting elastic plate, electric signal transducer and data acquisition H/W and S/W. Using such a velocimetry, two velocity measurement schemes were established which one is flow resistance detecting scheme and the other is Karman Vortex frequency detecting scheme. For calibration of each scheme, realistic flow water model was used and in followings, detailed calibration processes were explained.

  • PDF

유압관로에서 원통형 초크의 비정상 유동의 주파수 특성에 관한 연구 (Frequency Characteristics of Unsteady Flow of Cylindrical Choke in a Hydraulic Pipe)

  • 박선종;유영태;위광환
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.421-434
    • /
    • 1995
  • A new instantaneous flowmeter for hydraulics by means or cylindrical chokes is developed. In this method the instantaneous flowrate through chokes is predicted in real time from measurement of pressure difference on both sides of cylindrical choke. The experimental study for the flowrate of pulsating flow in a pipe is carried out to measure differential pressure drop by using a strain gauge pressure transducer with data acquisition and processing system. A pulsating flow is verified by a visualization method. In the present study, the flow characteristic variables of laminar pulsating flow are investigated analytically and experimentally in a circular pipe. Characteristic parameters of ratio of inertia term to pressure term($\phi_{t.1}$) and ratio of viscous term to pressure term($\phi_{z.1}$) are introduced to describe the flow pattern of laminar pulsating flow.

  • PDF

In vivo Evaluation of Flow Estimation Methods for 3D Color Doppler Imaging

  • Yoo, Yang-Mo
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권3호
    • /
    • pp.177-186
    • /
    • 2010
  • In 3D ultrasound color Doppler imaging (CDI), 8-16 pulse transmissions (ensembles) per each scanline are used for effective clutter rejection and flow estimation, but it yields a low volume acquisition rate. In this paper, we have evaluated three flow estimation methods: autoregression (AR), eigendecomposition (ED), and autocorrelation combined with adaptive clutter rejection (AC-ACR) for a small ensemble size (E=4). The performance of AR, ED and AC-ACR methods was compared using 2D and 3D in vivo data acquired under different clutter conditions (common carotid artery, kidney and liver). To evaluate the effectiveness of three methods, receiver operating characteristic (ROC) curves were generated. For 2D kidney in vivo data, the AC-ACR method outperforms the AR and ED methods in terms of the area under the ROC curve (AUC) (0.852 vs. 0.793 and 0.813, respectively). Similarly, the AC-ACR method shows higher AUC values for 2D liver in vivo data compared to the AR and ED methods (0.855 vs. 0.807 and 0.823, respectively). For the common carotid artery data, the AR provides higher AUC values, but it suffers from biased estimates. For 3D in vivo data acquired from a kidney transplant patient, the AC-ACR with E=4 provides an AUC value of 0.799. These in vivo experiment results indicate that the AC-ACR method can provide more robust flow estimates compared to the AR and ED methods with a small ensemble size.