DOI QR코드

DOI QR Code

In vivo Evaluation of Flow Estimation Methods for 3D Color Doppler Imaging

  • Yoo, Yang-Mo (Department of Electronic Engineering and Interdisciplinary Program of Integrated Biotechnology)
  • Received : 2010.01.13
  • Accepted : 2010.04.26
  • Published : 2010.04.01

Abstract

In 3D ultrasound color Doppler imaging (CDI), 8-16 pulse transmissions (ensembles) per each scanline are used for effective clutter rejection and flow estimation, but it yields a low volume acquisition rate. In this paper, we have evaluated three flow estimation methods: autoregression (AR), eigendecomposition (ED), and autocorrelation combined with adaptive clutter rejection (AC-ACR) for a small ensemble size (E=4). The performance of AR, ED and AC-ACR methods was compared using 2D and 3D in vivo data acquired under different clutter conditions (common carotid artery, kidney and liver). To evaluate the effectiveness of three methods, receiver operating characteristic (ROC) curves were generated. For 2D kidney in vivo data, the AC-ACR method outperforms the AR and ED methods in terms of the area under the ROC curve (AUC) (0.852 vs. 0.793 and 0.813, respectively). Similarly, the AC-ACR method shows higher AUC values for 2D liver in vivo data compared to the AR and ED methods (0.855 vs. 0.807 and 0.823, respectively). For the common carotid artery data, the AR provides higher AUC values, but it suffers from biased estimates. For 3D in vivo data acquired from a kidney transplant patient, the AC-ACR with E=4 provides an AUC value of 0.799. These in vivo experiment results indicate that the AC-ACR method can provide more robust flow estimates compared to the AR and ED methods with a small ensemble size.

Keywords

References

  1. D.H. Pretorius, T. R. Nelson, and J. S. Jaffe, "3-dimensional sonographic analysis based on color flow Doppler and gray scale image data: a preliminary report," J. Ultrasound Med., vol. 11, no. 5, pp. 225-232, 1992. https://doi.org/10.7863/jum.1992.11.5.225
  2. R. D. Simone, G. Glombitza, C. F. Vahl, J. Albers, H. P. Meinzer, and S. Hagl, "Three-dimensional color Doppler: a new approach for quantitative assessment of mitral regurgitant jets," J. Am. Soc. Echocardiogr., vo. 12, no. 3, pp. 173-185, 1999. https://doi.org/10.1016/S0894-7317(99)70133-1
  3. U. Herberg, H. Goldberg, and J. Breuer, ''Three- and four-dimensional freehand fetal echocardiography: a feasibility study using a hand-held Doppler probe for cardiac gating," Ultrasound Obstet. Gynecol., vol. 25, no. 4, pp. 362-371, 2005. https://doi.org/10.1002/uog.1839
  4. P. S. Mehwald, R. A. Rusk, Y. Mori, X. N. Li, A. D. Zetts, M. Jones, and D. J. Sahn, "A validation study of aortic stroke volume using dynamic 4-dimensional color Doppler: an in vivo study," J. Am. Soc. Echocardiogr., vol. 15, no. 10, pp. 1045-1050, 2002. https://doi.org/10.1067/mje.2002.122103
  5. R. Chaoui, J. Hoffmann, and K. S. Heling, "Three-dimensional (3D) and 4D color Doppler fetal echocardiography using spatio-temporal image correlation (STIC)," Ultrasound Obstet. Gynecol., vol. 23, no. 6, pp. 535-545, 2004. https://doi.org/10.1002/uog.1075
  6. C. Kasai, K. Namekawa, A. Koyano, and R. Omoto, "Real-time two-dimensional blood flow imaging using an autocorrelation techniques," IEEE Trans. Sonics. Ultrason., vol. 32, no. 3, pp. 458-463, 1985. https://doi.org/10.1109/T-SU.1985.31615
  7. H. Tsujino, M. Jones, T. Shiota, J.X. Qin, L. A. Cardon, A. J. Morehead, A. D. Zetts, F. Bauer, M. Stiges, X. Hang, N. L. Greenberg, J. A. Panza, and J. D. Thomas, "Impact of temporal resolution on flow quantification by real-time 3D color Doppler echocardiography: numerical modeling and animal validation study," Comput. Cardiol., vol. 27, pp. 761-764, 2000.
  8. J. Pemberton, L. Hui, M. Young, X. Li, A. Kenny, and D. J. Sahn, "Accuracy of 3-dimensional color Doppler-derived flow volumes with increasing image depth," J Ultrasound Med., vol. 24, no. 8, pp. 1109-1115, 2005. https://doi.org/10.7863/jum.2005.24.8.1109
  9. H. Torp, "Clutter rejection filters in color flow imaging: a theoretical approach," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 44, no. 2, pp. 417-424, 1997. https://doi.org/10.1109/58.585126
  10. S. Bjaerum, H. Torp, and K. Kristoffersen, "Clutter filters adapted to tissue motion in ultrasound color flow imaging," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 49, no. 6, pp. 693-704, 2002. https://doi.org/10.1109/TUFFC.2002.1009328
  11. Y. M. Yoo, R. Managuli, and Y. Kim, "An adaptive clutter filtering for ultrasound color flow imaging," Ultrasound Med. Biol., vol. 29, no. 9, pp. 1311-1320, 2003. https://doi.org/10.1016/S0301-5629(03)01014-7
  12. L.A.F. Ledoux, P.J. Brands and A.P.G. Hoeks, "Reduction of the clutter component in Doppler ultrasound signals based on singular value decomposition: a simulation study," Ultrason. Imaging, vol. 19, no. 1, pp. 1-18, 1997. https://doi.org/10.1177/016173469701900101
  13. D. E. Kruse and K. W. Ferrara, "A new high resolution color flow system using an eigendecomposition-based adaptive filter for clutter rejection," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 49, no. 12, pp. 1739-1754, 2002. https://doi.org/10.1109/TUFFC.2002.1159852
  14. T. Loupas and W. N. McDicken, "Low-order complex AR models for mean and maximum frequency estimation in the context of Doppler color flow mapping," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 37, no. 6, pp. 590-601, 1990. https://doi.org/10.1109/58.63118
  15. Y. B. Ahn and S. B. Park, "Estimation of mean frequency and variance of ultrasonic Doppler signal by using second-order autoregressive model," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 38, no. 3, pp. 172-182, 1991. https://doi.org/10.1109/58.79600
  16. M. E. Allam and J. F. Greenleaf, "Isomorphism between pulsed-wave Doppler ultrasound and direction-of-arrival estimation-part I: basic principles," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 43, no. 5, pp. 911-922, 1996. https://doi.org/10.1109/58.535495
  17. M. E. Allam, R. R. Kinnick, and J. F. Greenleaf, "Isomorphism between pulsed-wave Doppler ultrasound and direction-of-arrival estimation-part II: experimental results," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 43, no. 5, pp. 923-935, 1996. https://doi.org/10.1109/58.535496
  18. P. J. Vaitkus, and R. S. C. Cobbold, "A new time-domain narrowband velocity estimation technique for Doppler ultrasound flow imaging-part I: theory," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 45, no. 4, pp. 939-954, 1998. https://doi.org/10.1109/58.710565
  19. P. J. Vaitkus, R. S. C. Cobbold, and K. W. Johnston, "A new time-domain narrowband velocity estimation technique for Doppler ultrasound flow imaging-part II: comparative performance assessment," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 45, no. 4, pp. 955-971, 1998. https://doi.org/10.1109/58.710568
  20. Y. M. Yoo, S. Sikdar, K. Karadayi, O. Kolokythas, and Y. Kim, "Adaptive clutter rejection for 3D color Doppler imaging: preliminary clinical study," Ultrasound Med. Biol., vol. 34, no. 8, pp. 121-1231, 2008.
  21. Marple SL. Digital Spectral Analysis with Applications. Prentice Hall, Englewood Cliffs, NJ, 1987.
  22. Stoica P, Moses R. Introduction to Spectral Analysis. Prentice Hall, Upper Saddle River, NJ, 1997.