• Title/Summary/Keyword: Flow characteristics analysis

Search Result 4,760, Processing Time 0.041 seconds

Modelling and Simulation for PIG Flow Control in Natural Gas Pipeline

  • Nguyen, Tan-Tien;Yoo, Hui-Ryong;Park, Yong-Woo;Kim, Sang-Bong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.448-448
    • /
    • 2000
  • This paper deals with dynamic behaviour analysis for pipeline inspection gauge (PIG) flow control in natural gas pipeline. The dynamic behaviour of the PIG is depending on the different Pressure between the rear and nose parts, which is generated by injected gas flow behind PIG's tail and expelled gas flow in front of its nose. To analyze the dynamic behaviour characteristics such as gas flow in pipeline, and the PIG's position and velocity, mathematical model is derived as two types of a nonlinear hyperbolic partial differential equation for unsteady flow analysis of the PIG driving and expelled gas, and nonhomogeneous differential equation for dynamic analysis of PIG. The nonlinear equation is solved by method of characteristics (MOC) with the regular rectangular grid under appropriate initial and boundary conditions. The Runge-Kuta method is used when we solve the steady flow equations to get initial flow values and the dynamic equation of PIG. The gas upstream and downstream of PIG are divided into a number of elements of equal length. The sampling time and distance are chosen under Courant-Friedrich-Lewy (CFL) restriction. The simulation is performed with a pipeline segment in the Korea Gas Corporation (KOGAS) low pressure system, Ueijungboo-Sangye line. The simulation results show us that the derived mathematical model and the proposed computational scheme are effective for estimating the position and velocity of PIG with different operational conditions of pipeline.

  • PDF

Numerical analysis of plasma effect on fluid flow in a supersonic flow (플라즈마에 의한 초음속 유동 변화 해석)

  • Park, Sul-Ki;Cho, Hyung-Hee;Song, Ji-Woon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.369-372
    • /
    • 2009
  • A numerical analysis of the effect of plasma on flow characteristics in supersonic flow is studied. It is shown that change of direction and velocity magnitude of flow is appeared different in relative direction of plasma and fluid flow. The case of that direction of electrons, which are same with flow direction, the flow is accelerated, and the case of opposition, the flow is decelerated.

  • PDF

Fluid Flow Characteristics in the Aquaculture Tank for a Breeding Fish

  • Jeong, Hyo-Min;Chung, Han-Shik;Kim, Se-Hyun;Choi, Seuk-Cheun;Bae, Kang-Youl
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.12
    • /
    • pp.2265-2272
    • /
    • 2004
  • The aquaculture tank is used for breeding fish in sea water which was pumped up to land. The flow characteristics in the aquaculture were investigated with varying the tank geometry and flow rate. The numerical analysis has been employed for calculating the velocity and temperature distributions in a water tank of rectangular type. The finite volume method and SIMPLE algorithm with 3-dimensional standard $\kappa$-$\varepsilon$ turbulence model were used for the numerical analysis. For comparison with experimental results, the PIV system was applied to visualize the flow patterns quantitatively. The numerical results showed good agreements with the experimental results. The mean velocity and temperature versus aquarium depth were represented for various circulating flow rates. Especially, the aquaculture environment is recommended that the aquarium depth has to be d=0.5 m, and this case is the condition of higher velocity and temperature in winter season.

Analytical Study on Unsteady Flow Characteristics of Urea-SCR Single Hole Injector depend on Nozzle Shape Change (Urea-SCR 단홀 Injector 노즐형상 변화에 따른 비정상유동특성의 해석적 연구)

  • Hwang, Jun Hwan;Park, Sung-Young
    • Journal of ILASS-Korea
    • /
    • v.24 no.3
    • /
    • pp.105-113
    • /
    • 2019
  • In this paper, a study of Urea-SCR System for Dosing Injector for responding to enhanced environmental regulations has been conducted. There is a limit to the experimental approach due to the structural characteristics of the injector. In order to overcome this problem, The analysis was performed assuming unsteady turbulent flow through computational fluid analysis and the internal flow characteristics of the injector were analyzed. By changing the nozzle shape of the injector, the performance factors of the swirl injector by shape were selected and compared. The design parameters were modified by changing the diameter of the nozzle at a constant ratio compared to the base model. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. The Conv. model to which the taper was applied showed the dominance in mass flow rate, discharge coefficient and swirl because of the smooth fluid flow by shape. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. As a result of the comparison coefficient derivation with those performance parameters for comparing the performance of the model-specific injector, the Conv-140 model with the nozzle diameter expanded by 140% showed the best value of the comparison coefficient.

Characteristic of the non-Newtonian fluid flows with vibration (진동장에서의 비뉴턴유체 유동의 특성)

  • Choi, Sung-Ho;Shin, Se-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2048-2053
    • /
    • 2003
  • The present study investigated the effect of the transversal vibration on the flow characteristics for non-Newtonian fluids. The effect was tested by experiment and numerical analysis. For Newtonian fluids, both of experiment and numerical analysis results showed that mechanical vibration did not affect the flow rate. For non-Newtonian fluids, however, there was significant disagreement between experiment and numerical results. The numerical results showed a negligibly small effect of vibration on the flow rate whereas experimental results showed a significant flow rate increase associated with transversal vibration. The results implied that the increased flow rate was caused not only by imposed shear rates at the wall but also by the changes of rheological characteristics due to the transversal vibration.

  • PDF

A Study on Effect of Flow Characteristics for Turbine Impeller Shape (Turbine Impeller 형상이 유동특성에 미치는 영향에 관한 연구)

  • Jeon, Eon-Chan;Youn, Gi-Ho;Kang, Chang-Hun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.4
    • /
    • pp.36-43
    • /
    • 2014
  • Recently, research has been conducted to develop the ORC (organic Rankine cycle), to recover waste heat from facilities such as industrial plants ultimately to create mechanical or electrical energy. The ORC system consists of a heat exchange, a condenser, a pump and a boiler. In this paper, 84 flow analyses were conducted with 21 cases and three variables, i.e., a number of large wings, a number of small wings, and RPMs. R245fa was used as a refrigerant. The flow cavitation phenomenon was investigated through a flow analysis, and a flow stream analysis was conducted.

Analysis of Performance Characteristics in the Counter and Parallel Type Plate Evaporator with Operating Methods (대향류와 평행류형 판형 증발기에서 운전방식에 따른 성능특성 분석)

  • Bae, Kyung-Jin;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.50-56
    • /
    • 2013
  • The analysis of performance characteristics was carried out in the plate type evaporator with counter and parallel flow. To investigate performance of evaporator with water inlet temperature and refrigerant mass flow rate were changed. As a result, when the inlet temperature of water is $8^{\circ}C$, capacity of parallel flow evaporator higher than counter flow is 0.35%. But as the inlet temperature of water rises from $8^{\circ}C$ to $16^{\circ}C$, capacity of counter flow type evaporator higher than parallel flow type is 0.12%, 0.27%, 1.1%, 1.6%, respectively. The findings showed that counter flow type evaporator has a larger capacity than those that were parallel flow type evaporator. As the refrigerant mass flow rate rises, capacity and pressure drop increases in the counter and parallel flow type evaporator.

Hydraulic Characteristics of Bocheong Stream Basin (보청천 유역의 수리학적 특성분석)

  • Jeon, Min-Woo;Yeon, Gyu-Bang;Cho, Young-Soo;Kim, Chong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1311-1315
    • /
    • 2009
  • Understanding of the hydraulics of flow is very important to support the management of river. The cross-sectional area, average velocity, flow depth and discharge can be regarded as a power function each other. In this paper the flow of Bocheong stream basin is experimentally studied. The correlation analysis was performed between observed hydraulic factors by the power type function. The constants resulted from the correlation analysis were calculated by the geomorphologic characteristics of the watershed using the power type function. The correlation coefficients between the hydraulic factors were appeared close to unit having strong correlationship. The two conditions of equality of the continuity equation were analysed, and the conditions were found to be good results. From these results the observed hydraulic data of Bocheong stream basin can be concluded as a reliable data. The correlation coefficients between the parameters of the hydraulic characteristics and geomorphologic factors were found to be close to unit.

  • PDF

Numerical Analysis of the Unsteady Subsonic Flow around a Plunging Airfoil

  • Lee, Kyungwhan;Kim, Jaesoo
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 2013
  • Much numerical and experimental research has been done for the flow around an oscillating airfoil. The main research topics are vortex shedding, dynamic stall phenomenon, MAV's lift and thrust generation. Until now, researches mainly have been concentrated on analyzing the wake flow for the variation of frequency and amplitude at a low angle of attack. In this study, wake structures and acoustic wave propagation characteristics were studied for a plunging airfoil at high angle of attack. The governing equations are the Navier-Stokes equation with LES turbulence model. OHOC (Optimized High-Order Compact) scheme and 4th order Runge-Kutta method were used. The Mach number is 0.3, the Reynolds number is, and the angle of attack is from $20^{\circ}$ to $50^{\circ}$. The plunging frequency and the amplitude are from 0.05 to 0.15, and from 0.1 to 0.2, respectively. Due to the high resolution numerical method, wake vortex shedding and pressure wave propagation process, as well as the propagation characteristics of acoustic waves can be simulated. The results of frequency analysis show that the flow has the mixed characteristics of the forced plunging frequency and the vortex shedding frequency at high angle of attack.

A Study of the Analysis of Characteristics of Nonlinear Dynamic System on Blood-Flow of Peripheral Blood-Vessel between Diabetic Patients and Control Subjects (당뇨병환자와 정상인의 말초혈관혈류의 비선형적 운동계 분석에 대한 연구)

  • Kim, D.H.;Choi, J.Y.;Yi, S.H.;Go, H.W.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.363-367
    • /
    • 1996
  • In general, the physiological systems have shown nonlinear complex phenomena. This study analyzes nonlinear characteristics of the flow of peripheral blood vessel dynamics in physiological systems using chaos theory. We performed this study by means of several quantity methods and power spectrum. The quantity methods are a phase space reconstruction and a poincare's map. And the power spectrum method is a conventional linear analysis. Experimental data have been acquired from examining 10 diabetic patients, and 10 control subjects in initial stable state. In acquisition experminetal data, we anlysized the differences of nonlinear characteristics between diabetic group and control group. The results of quality analysis methods showed the flow of peripheral blood vessel had the nonlinear and chaotic characteristics, screening a strange attractor on reconstructed phase space. In conclusion, the flow dynamics of peripheral blood vessel had a chaotic behavior of nonlinear dynamic systems, dynamic system, and differences of characteristic of nonlinear dynamic system.

  • PDF