• Title/Summary/Keyword: Flow Speed Measurement

Search Result 349, Processing Time 0.028 seconds

The Flow Analysis for Vibration and Noise Diagnostic of Vacuum Cleaner Fan Motor (진공청소기 팬 모터의 진동 및 소음원인 분석을 위한 유동해석)

  • 김재열;곽이구;안재신;양동조;송경석;박기형
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.56-63
    • /
    • 2004
  • Recently technology resulted in highly efficient and multiple-functional electric appliances considering environmental problems. One of the environmental problems is noise of a product in respect to its function. A vacuum cleaner is an essential electric appliance in our daily lives. However, severe noise resulted from high motor speed for improving the function of the appliance is a nuisance for the user. This noise is caused by vibration from various parts of the appliance and fluid noise during a series of intake and exhaust processes while rotating the impeller connected to the axle at a high speed of the fan motor inside the vacuum cleaner rotating around 30,000-35,000rpm. Despite the fact that many researchers conducted studies on reducing the noise level of the fan motor in a vacuum cleaner, only few studies have been conducted considering both the theoretical and experimental aspects using fluid analysis by measuring vibration and noise. Moreover, there has not been a study that accurately compared major noise data obtained considering both of the aspects. In this study, both aspects were considered by considering the following experimental and theoretical methods to verify the major causes of noise from the fan motor in a vacuum cleaner.

Bandwidth-Related Optimization in High-Speed Frequency Dividers using SiGe Technology

  • Nan, Chao-Zhou;Yu, Xiao-Peng;Lim, Wei-Meng;Hu, Bo-Yu;Lu, Zheng-Hao;Liu, Yang;Yeo, Kiat-Seng
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.107-116
    • /
    • 2012
  • In this paper, the trade-off related to bandwidth of high-speed common-mode logic frequency divider is analyzed in detail. A method to optimize the operating frequency, band-width as well as power consumption is proposed. This method is based on bipolar device characteristics, whereby a negative resistance model can be used to estimate the optimal normalized upper frequency and lower frequency of frequency dividers under different conditions, which is conventionally ignored in literatures. This method provides a simple but efficient procedure in designing high performance frequency dividers for different applications. To verify the proposed method, a static divide-by-2 at millimeter wave ranges is implemented in 180 nm SiGe technology. Measurement results of the divider demonstrate significant improvement in the figure of merit as compared with literatures.

Localization of Acoustic Sources on Wind Turbine by Using Beam-forming Techniques (빔-형성 기법을 이용한 풍력 터빈 음원의 국부화)

  • Lee, Gwang-Se;Shin, Su-Hyun;Cheong, Cheol-Ung;Jung, Sung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.63-67
    • /
    • 2009
  • The previous work (Cheong et al., 2006) where the characteristics of acoustic emissions of wind turbines has been investigated according to the methods of power regulation, has showed that the acoustic power of wind turbine using the stall control for power regulation is more correlated with the wind speed than that using the pitch control. In this paper, basically extending this work, the noise generation characteristics of large modern upwind wind turbines are experimentally indentified according to the power regulation methods. To investigate the noise generation mechanisms, the distribution of noise sources in the rotor plane is measured by using the Beam-forming measurement system (B&K 7768, 7752, WA0890) consisting of 48 microphones. The array results for the 660 kW wind turbine show that all noise is produced during the downward movement of the blades. This result show good agreement with the theoretical result using the empirical formula with the parameters: the convective amplification; trailing edge noise directivity; flow-speed dependence. This agreement implies that the trailing edge noise is dominant over the whole frequency range of the noise from the 660 kW wind turbine using the pitch control for power regulation.

  • PDF

A Study on the Measurement of Flame Visualization, Temperature and Soot for Diffusion Flame in a Diesel Engine Using High-Speed Camera (고속카메라를 이용한 디젤엔진내의 화염 가시화, 화염의 온도 및 매연 측정에 관한 연구)

  • Han, Yong-Taik;Lee, Ki-Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.132-140
    • /
    • 2007
  • The temperature and soot of the visualized diesel engine's turbulent flow of the flame was measured qualitatively. In the combustion chamber, in order to judge the affect that the swirl current has on the current ratio two heads with different ratios were used. Using a high speed camera, the results were analyzed using flame visualization. In order to measure the temperature and soot of the turbulent flames like diesel flames, two color methods were used to acquire temperature and the soot of the flames according to the conditions through analyzing the two wavelengths of the flames. It was possible to measure the highest temperature of the non-swirl head visualized engine, which is approximately 2400K, and that swirl head engine managed up to 2100K. With respect to the visualized diesel engine soot, we got the grasp of the KL factor which bears the qualitative information of the soot. This study is dedicated to suggesting the possibility of measuring not only the temperature but also soot of the diffusion flame of the diesel engine turbulent flames.

Development of a Multi-Component Waterproof Type Force Sensor Devised with Column Elements Under Eccentric Load (편심하중 요소를 활용한 방수형 다분력 검력계 개발)

  • Hyochul Kim;Changhwan Shin;Seongsun Rhyu;Younjae Ham
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.61 no.3
    • /
    • pp.200-207
    • /
    • 2024
  • A multi-component force sensor has been developed to measure force and moment components in high-speed flow media for submerged models. The size of the test model is determined based on the Reynolds number of the model at the test speed and expected blockage effect. A two-component force sensor unit has been created by assembling pairs of column elements arranged symmetrically under an eccentric load. The six-component force sensor is constructed with symmetric arrangements of two-component force sensor units in a rectangular plane. The signals generated from the strain gauges attached to the surface of the elements can be converted into force signals. The performance of the waterproof six-component force sensor has been evaluated through calibration. A simplified interference decomposition procedure has been introduced to increase the accuracy of measurement.

Development of a High Resolution Cinematic Particle Image Velocimetry and Its Application to measurement of Unsteady Complex Turbulent Flows (고분해능 Cinematic PIV 시스템의 개발과 비정상 복잡 난류유동측정에의 응용)

  • Kim, Kyung-Chun;Park, Kyung-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.536-541
    • /
    • 2001
  • A high resolution digital cinematic Particle Image Velocimetry(PIV) has been developed. The system consists of a high speed CCD camera, a continuous Ar-ion laser and a computer with camera controller. To improve the spatial resolution, we adopt a Recursive Technique for velocity interrogation. At first, we obtain a velocity vector for a larger interrogation window size based on the conventional two-frame cross-correlation PIV analysis using the FFT algorithm. Based on the knowing velocity information, more spatially resolved velocity vectors are obtained in the next iteration step with smaller interrogation windows. The correct velocity vector at the first step is found to be critical, so we apply a Multiple Correlation Validation(MCV) technique in order to decrease the spurious vectors. The MCV technique turns out to improve SNR(Signal to Noise Ratio) of the correlation table. The developed cinematic PIV method has been applied to the measurement of the unsteady flow characteristics of a Rushton turbine mixer. A total of 3,245 instantaneous velocity vectors were successfully obtained with 4 ms time resolution. The acquired spatial resolution corresponds the performance of the conventional high resolution digital PIV system using a $1K{\times}1K$ CCD camera.

  • PDF

An Experimental Study on the Improvement of Resistance Performance at Pre-planing Condition for G/T 100 ton Class Planing Hull Form (총톤수 100톤급 활주형선의 활주 전 저항성능 개선에 관한 실험적 연구)

  • Lee, Kwi-Joo;Joa, Soon-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.1
    • /
    • pp.17-22
    • /
    • 2004
  • This study was carried out at the CWC of Chosun university for the purpose of resistance performance improvement of planing hull, and the results of the tests were confirmed cooperatively with WJFEL. G/T 100 ton class planing hull form was selected, and the improvement of hull form including appendages were performed by using some model test techniques. The model test scope comprises resistance relative tests including wave profile observation, trim and sinkage measurement and flow visualization tests at full load and trial conditions for one bare hull and for two appended hulls. The final wedge and spray strip combined with improved hull form showed about 1.0 knot speed improvement at both of full and trial conditions, and outstanding improvement for fore wave phenomena.

The stable design of radiant heat inside PCB circuit board device (PCB회로 보드장치내의 안정적 방열설계를 위한 연구)

  • Won, Jong-Wun;Lee, Jong-Hwi
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.2
    • /
    • pp.129-134
    • /
    • 2013
  • In this study, the heat flow analysis compatible commercial code CFX 11 was used to develop the structure inside PCB circuit board devices, which could stable radiant heat as well as the cooling device within it. In case of modifying the arrangement of electronic parts on the PCB inside the multi channel temperature measurement board devices, radiant heat effects did not show a rising tendency, whereas the overall temperature went down in case of installing the vents in the outer case of PCB circuit board devices. In terms of installation location, it was the most appropriate to install it on the electronic parts with no heat. Besides, in case of mounting the fan as a cooling device by considering various user environments for multi channel temperature measurement board devices, the radiant heat effects were shown higher than in case of installing the vents, and the middle sections were the most appropriate to its installation location. In case of changing the wind quantity of the fan from its selected installation location, the best radiant heat effects were shown at high speed as expected.

Measurement and Analysis of Moving Velocity of Elementary School Students Under a Escape Drill (초등학생의 피난 훈련 상황하에서의 이동속도 측정 및 분석에 관한 연구)

  • 김응식;이정수;김수영
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.1-6
    • /
    • 2003
  • This study measures the various moving velocities of elementary school children under situation of fire drill and suggests the methods of analysis. The velocities are such as the exiting velocity at the door of the classroom, personal walking velocity at corridor, velocity according to density of crowd and personal walking velocity at stairway. For these measurement an elementary school in Daejeon is chosen and 15 girls and 15 boys are selected in each grade. Finally speed data of the children is obtained and we can apply this data for the evacuation simulation of a school.

Influence of Cutting Pressure on Laser Cut Quality (Relationship between Cutting Pressure and Cut Quality) (레이저 절단품질에 미치는 절단압력의 영향(2) (절단압력과 절단품질간의 상관관계))

  • Yang, Yeong-Su;Na, Seok-Ju;Kim, Won-Bae;Kim, Tae-Gyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.5 no.1
    • /
    • pp.63-70
    • /
    • 1988
  • Laser cutting system uses a gas jet to remove the molten or varpozed material from the workpiece. The quality of the laser cut can be strongly influenced by the gas flow charac- teristics formed through the nozzle. Laser cutting experiments were carried out for SS41 and SUS 304 to investigate the relationship between cut quality and cutting pressure. The cutting speed, nozzle pressure and nozzle to workpiece distance were also considered. The cut specimens were inspected by various manners such as dross observation, surface roughness test and kerf width measurement. Based on the data of pressure measurement on workpiece and the results of cut surface inspection, the influence of the considered cutting conditions on cut quality could be evaluated. The results of this study will be valuable in planning the optimal laser cutting process and in designing the laser cutting nozzle.

  • PDF