• Title/Summary/Keyword: Flow Measuring Accuracy

검색결과 121건 처리시간 0.028초

Thermal Conductivity Measurement of Insulation Material for Superconducting Application

  • Chol, Y.S.;Kim, D.L.;Shin, D.W.;Hwang, S.D.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권2호
    • /
    • pp.29-32
    • /
    • 2011
  • The thermal properties of insulation material are essential to develop a high-temperature superconducting (HTS) power cable to be operated at around liquid nitrogen temperature. Unlike metallic materials, nonmetallic materials have a high thermal resistance; therefore special attention needs to be paid to estimate heat flow correctly. Thus, we have developed a precise instrument for measuring the thermal conductivity of insulating materials over a temperature range from 40 K to near room temperature using a cryocooler. Firstly, the measurement of thermal conductivity for Teflon is carried out for accuracy confirmation. For a supplied heat flux, the temperature difference between warm and cold side is measured in steady state, from which the thermal conductivity of Teflon is calculated and compared with published result of NIST. In addition, the apparent thermal conductivity of Polypropylene laminated paper (PPLP) is presented and its temperature dependency is discussed.

가중계수에 의한 다회선 초음파유량계의 유량적분오차 (Flowrate Integration Errors of Multi-path Ultrasonic Flowmeter using Weighting Factors)

  • 이호준;황상윤;김경진
    • 한국유체기계학회 논문집
    • /
    • 제7권5호
    • /
    • pp.7-12
    • /
    • 2004
  • Multi-path ultrasonic flowrate measuring technology is being received much attentions from a variety of industrial fields to exactly measure the flowrate. Multi-path ultrasonic flowmeter has much advantage since it has no moving parts and little pressure loss. It offers good accuracy, repeatability, linearity and turn-down ratio can be over 1:50. The present study investigates flowrate integration errors using weighting factors. A theoretical flow model uses power law to describe a fully developed velocity profiles and wall roughness is changed. Gaussian, Chebyshev, and Tailor methods are used to integrate line-average velocities. The obtained results show that Chebyshev method in 2, 4-path arrangement and Gaussian method in 3, 5-path arrangement are not affected for wall roughness changes.

Evaluation of Flow Experience by using Psychophysiological Visual Feedbacks

  • Kim, Jung Yong;Min, Seung Nam;Park, Yong Duck
    • 대한인간공학회지
    • /
    • 제32권6호
    • /
    • pp.481-487
    • /
    • 2013
  • Objective: The present study aims to evaluate the visual reactions of users when they are playing games of different flow levels, and to explore the visual variables that can sensitively reflect the different flow levels. Background: The flow is defined as a psychological state where interface users feel their actions in a virtual setting identical to those in real environment. To measure the flow states of users, the questionnaire-based FSS(Flow State Scale) has mostly been used. However, this method is a qualitative test that has limits in terms of the accuracy of users' flow experiences. Therefore, more accurate methods to measure users' flow experiences are required. Method: Ten subjects participated in the experiment, where the independent variables were three games with different flow levels(puzzle games, dot drawing and coloring) and the time frame(the first and last 10 seconds in game playing), whereas the dependent variables included the pupil size and the frequency and duration of eye blinking. This study was a within-subject design. Each participant performed three types of games with different flow levels 3 times for each for 10 minutes, and their visual reactions to each game were measured. Results: The higher the flow cause the bigger pupil size(p<0.01) and the lower eye blinking frequency(p<0.1), indicating that different types of games lead to different flow levels. The pupil size during the last 10 seconds when the flow level was higher was bigger by 2.1% compared with that during the first 10 seconds in game playing(p<0.1), and the eye blinking frequency decreased by 12%(p<0.01). Conclusion: It was found out that the pupil size and the frequency and duration of eye blinking were psychophysiological indices for evaluating users' flow experiences, which could quantify the flow states users go through. The psychophysiological variables capable of measuring diverse aspects of the flow need diversifying to be applicable to precise measurement of the flow. Application: These studies are warranted for both quantitative analysis of flow levels and qualitative improvement of cyber leisure in line with development of healthy games.

PM2.5 국가기준측정장비 선정을 위한 비교 측정 연구 (Field Performance Evaluation of Candidate Samplers for National Reference Method for PM2.5)

  • 이용환;박진수;오준;최진수;김현재;안준영;홍유덕;홍지형;한진석;이강웅
    • 한국대기환경학회지
    • /
    • 제31권2호
    • /
    • pp.157-163
    • /
    • 2015
  • To establish National Reference Method (NRM) for $PM_{2.5}$, operational performance of 5 different commercial gravimetric-based $PM_{2.5}$ measuring instruments was assessed at Bulkwang monitoring station from January 23, 2014 to February 28, 2014. First, physical properties, design, and functional performance of the instruments were assessed. Evaluation was carried out to determine whether operating method for the instruments and levels of QA/QC activities meet the data quality objectives (DQOs). To verify whether DQOs were satisfied, reproducibility of QA/QC procedures, accuracy, relative sensitivity, limit of detection, margin of error, and coefficient of determination of the instruments were also evaluated. Results of flow rate measurement of 15 candidate instruments indicated that all the instruments met performance criteria with accuracy deviation of 4.0% and reproducibility of 0.6%. Comparison of final $PM_{2.5}$ mass concentrations showed that the coefficient of determination ($R^2$) values were greater than or equal to 0.9995, and concentration gradient ranged from 0.97 to 1.03. All the instruments satisfied criteria for NRM with the estimated precision of 1.47~2.60%, accuracy of -1.90~3.00%, and absolute accuracy of 1.02~3.12%. This study found that one particular type of measuring instrument was proved to be excellent, with overall evaluation criteria satisfied.

ADCP를 이용한 직선 하천의 유속 및 수심 측정 정확도 분석 (Accuracy Analysis of Velocity and Water Depth Measurement in the Straight Channel using ADCP)

  • 김종민;김동수;손근수;김서준
    • 한국수자원학회논문집
    • /
    • 제48권5호
    • /
    • pp.367-377
    • /
    • 2015
  • 최근 수문관측의 측정 인력과 비용의 절감과 측정 정확도를 높이기 위해 초음파를 이용한 ADCP 유량 측정 방법의 적용이 활발하게 이루어지고 있으며 점점 그 비중이 높아지고 있다. 하지만 ADCP의 유속 및 수심 측정 정확도에 대한 자료가 부족하여 ADCP 측정 결과에 대한 신뢰도를 확신하기 어렵다. 이에 본 연구에서는 직선하천에서 체계적이고 정밀한 측정을 통해 ADCP의 유속 및 수심 정확도를 분석하였다. ADCP의 유속 측정 정확도를 분석하기 위해 횡단면에 184개의 측점에서 측정한 ADV 유속 측정 결과와 ADCP의 유속 측정 결과를 비교하여 오차를 계산하였다. 그 결과 바닥을 기준으로 수심비(y/h)가 0.4~0.8 범위에서는 ADCP가 정확하게 유속을 측정하는 것으로 나타났으나, 수면 근처에서는 유속을 작게 측정하였고, 하상 근처에서는 유속을 크게 측정하여 정확도가 떨어지는 것을 확인하였다. 또한 ADCP의 수심 정확도를 분석한 결과 하상추적(bottom tracking) 방식이 약 6%의 오차를 보였고, 연직 빔(vertical beam) 방식이 약 9%의 오차를 보여 식생이 활착한 자연하천의 경우 하상추적 방식이 좀 더 정확하게 수심을 측정하는 것으로 확인하였다. 그리고 고정 측정 방법과 이동 측정 방법의 차이를 검토한 결과 두 방법 모두 유사한 정확도를 나타냈다. 이와 같은 연구 결과는 향후 ADCP의 측정 불확도 평가를 위한 기초 자료로 활용한다면 ADCP를 하천에 적용함에 있어 좀 더 정확한 유속 및 수심 측정이 가능할 것으로 기대된다.

수압 측정에 기반하는 요류검사의 정확도 검증 (Accuracy Validation of Urinary Flowmetry Technique Based on Pressure Measurement)

  • 최성수;이인광;김군진;강승범;박경순;이태수;차은종;김경아
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.198-204
    • /
    • 2008
  • Uroflowmetry is a non-invasive clinical test useful for screening benign prostatic hyperplasia(BPH) common in the aged men. The current standard way to obtain the urinary flow rate is to continuously acquire the urine weight signal proportional to volume over time. The present study proposed an alternative technique measuring pressure to overcome noise problems present in the standard weight measuring technique. Experiments were performed to simultaneously acquire both weight and pressure changes during urination of 9 normal men. Noise components were separated from volume signals converted from both weight and pressure signals based on the polynomial signal model. Signal-to-noise ratio was defined as the ratio of the energies between signal and noise components of the measured volume changes, which was 8.5 times larger in the pressure measuring technique, implying that cleaner signal could be obtained, more immune to noisy environments. When four important diagnostic parameters were estimated, excellent correlation coefficients higher than 0.99 were resulted with mean relative errors less than 5%. Therefore, the present pressure measurement seemed valid as an alternative technique for uroflowmetry.

mini-Wright Peak Flow Meter에 의한 PEFR 측정의 정확도 (An Evaluation of the Accuracy of Mini-Wright Peak Flow Meter)

  • 고영일;최인선;나현주;박석채;장안수
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권2호
    • /
    • pp.298-308
    • /
    • 1997
  • 연구배경 : 휴대용 PFMs에 의한 PEFR측정은 쉽고 간편하여 천식의 진단과 추적관찰에 널리 이용되고 있는데, 이들에 의해 측정된 PEFR성적이 얼마나 믿을만 할 것인지는 의문이다. 따라서 저자는 전산화폐기능검사기계인 pneumotachygraph를 기준으로 MPFM에 의한 PEFR측정의 정확도, 일치성, 정밀성을 검토하고자 하였다. 방 법 : 22례의 정상인과 17례의 경증 및 중등도의 천식환자를 대상으로 휴대용 PFMs인 MPFM로 PEFR을 측정하였고 전산화폐기능검사기계인 pneumotachygraph로 폐환기기능검사를 시행하였으며, 이중 정상인만을 대상으로 서로 다른 3일 동안 연속적으로 같은 방법으로 폐기능검사를 시행하여 다음과 같은 결과를 얻었다. 결 과 : 정상인과 환자군 모두에서 MPFM로 측정한 PEFR은 pneumotachygraph 에 의해 측정한 PEFR, $FEV_1$과 유의한 순상관관계에 있었다(for PEFR, r = 0.92, p < 0.001 ; for $FEV_1$, r = 0.78 ; p < 0.001). 정상인과 환자군 모두에서 MPFM로 측정한 PEFR은 pneumotachygraph로 측정한 PEFR과 평균 16.5L/min의 차이(측정된 실제 PEFR의 2.90%)를 보였고 정상인만을 대상으로 했을 때는 10.6L/min의 차이(측정된 실제 PEFR의 1.75%)를 보여 NAEP에서 추천한 정확도의 기준 10%이내로 높은 정확도를 나타냈다. 정상인과 환자군 모두에서 MPFM로 측정한 PEFR과 pneumotachygraph로 측정한 PEFR사이의 Bland-Altman방법에 의한 일치성은 회귀방정식을 이용해 교정했을 때 -71.5~+38.2L/min을 보였고 정상인만을 대상으로 했을 때는 -20.49~+9.49L/min을 보여, 정상인에서 연속 3 일간 얻은 개체내 일치성과 유사하였다. 정상인만을 대상으로 연속 3일간 MPFM로 측정한 PEFR과 pneumotachygrph에 의한 폐기능성적은 각각 횟수에 따라 유의한 차이가 없었고(p > 0.05), MPFM에 의한 PEFR의 CV는 $2.4{\pm}1.2%$로서 pneumotachygraph에 의한 $5.2{\pm}3.5%$보다 유의하게 작았다(p < 0.05). 결 론 : 이상의 성적으로 MPFM에 의해 측정한 PEFR은 전산화폐기능검사기계에 의한 폐기능성적과 다를 바 없는 좋은 성적을 측정할 수 있어서 기관지 천식환자의 폐기능상태의 변화양상을 추적관찰하는데 유용한 것으로 사료되었다.

  • PDF

Machine Learning Model to Predict Osteoporotic Spine with Hounsfield Units on Lumbar Computed Tomography

  • Nam, Kyoung Hyup;Seo, Il;Kim, Dong Hwan;Lee, Jae Il;Choi, Byung Kwan;Han, In Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.442-449
    • /
    • 2019
  • Objective : Bone mineral density (BMD) is an important consideration during fusion surgery. Although dual X-ray absorptiometry is considered as the gold standard for assessing BMD, quantitative computed tomography (QCT) provides more accurate data in spine osteoporosis. However, QCT has the disadvantage of additional radiation hazard and cost. The present study was to demonstrate the utility of artificial intelligence and machine learning algorithm for assessing osteoporosis using Hounsfield units (HU) of preoperative lumbar CT coupling with data of QCT. Methods : We reviewed 70 patients undergoing both QCT and conventional lumbar CT for spine surgery. The T-scores of 198 lumbar vertebra was assessed in QCT and the HU of vertebral body at the same level were measured in conventional CT by the picture archiving and communication system (PACS) system. A multiple regression algorithm was applied to predict the T-score using three independent variables (age, sex, and HU of vertebral body on conventional CT) coupling with T-score of QCT. Next, a logistic regression algorithm was applied to predict osteoporotic or non-osteoporotic vertebra. The Tensor flow and Python were used as the machine learning tools. The Tensor flow user interface developed in our institute was used for easy code generation. Results : The predictive model with multiple regression algorithm estimated similar T-scores with data of QCT. HU demonstrates the similar results as QCT without the discordance in only one non-osteoporotic vertebra that indicated osteoporosis. From the training set, the predictive model classified the lumbar vertebra into two groups (osteoporotic vs. non-osteoporotic spine) with 88.0% accuracy. In a test set of 40 vertebrae, classification accuracy was 92.5% when the learning rate was 0.0001 (precision, 0.939; recall, 0.969; F1 score, 0.954; area under the curve, 0.900). Conclusion : This study is a simple machine learning model applicable in the spine research field. The machine learning model can predict the T-score and osteoporotic vertebrae solely by measuring the HU of conventional CT, and this would help spine surgeons not to under-estimate the osteoporotic spine preoperatively. If applied to a bigger data set, we believe the predictive accuracy of our model will further increase. We propose that machine learning is an important modality of the medical research field.

토양 유실량 및 유출수량 측정을 위한 회전분할집수기의 평가 (Design and Evaluation of a Flow Rotate Divider for Sampling Runoff Plots.)

  • 장용선;박찬원;이계준;이정태;진용익;황선웅
    • 한국토양비료학회지
    • /
    • 제41권6호
    • /
    • pp.374-378
    • /
    • 2008
  • 기존의 전량집수법은 유실된 토양과 물을 전부 채취하기 위하여 시험대상지 하부에 낙차를 두어 일정규모의 집수조를 설치하여야 하고, 유실 토양과 유출 수를 측정한 후에는 집수조 내부의 토양과 물을 전부 제거해야 하므로 집수조의 설치 및 관리에 많은 노력과 비용이 소요된다. 이러한 집수구 설치 및 관리상의 문제점을 개선하기 위하여 토양보전시험연구를 위하여 장소선정이 용이하고, 시험포장에서 배출되는 토양유실 및 유출수의 측정과 시료채취 작업이 간편한 회전분할집수기를 제작하여 기존의 표준방법과 비교하였다. 농경지에서 유실되는 토양과 물을 일정 비율로 채취하기 위하여 집수기의 원형판을 8부분으로 분할하여 각 날개에 일정량의 물이나 토양이 채워지면 무게 중심이 아래로 이동하는 방법으로 소량의 물이나 토양에 의해 자체 회전하면서 시료 중 일부만 채취하도록 하였고, 집수기 자체의 각도를 기울여 각각의 날개에 채워진 유출수와 유실토양은 원형판이 가장 낮은곳에서 회전할 때 비워지도록 하였다. 회전분할집수기의 정밀도를 비교하기 위하여 실내실험으로 유수량을 $1{\sim}10L\;min^{-1}$로 조절하여 유출수량과 회전분할집수기의 채취량을 비교한 결과 고도의 직선적인 정의상관 ($r=0.997^{***}$)을 보였으며, 야외 시험포장에서 회전분할집수기 시제품을 설치하여 측정한 결과 집수비율은 토양 유실량 및 물 유출량이 많을수록 정밀도가 높았다.

유수율 향상을 위한 수도미터의 불감률 특성 연구 (A Study on Characteristics of Under Registration Rate for Water Meters to Increase the Accounted Water Rate)

  • 이동근;박종호
    • 대한기계학회논문집B
    • /
    • 제34권8호
    • /
    • pp.791-797
    • /
    • 2010
  • 수도미터를 통한 유량측정 및 분석결과의 신뢰성은 측정정확도에 따라 좌우된다. 수도미터의 불감률은 수도사업자에게 재정손실이나 유수율 감소와 같은 많은 문제점을 야기시킨다. 본 연구의 목적은 실험적인 방법을 통하여 효율적인 운영관리 기술과 차별화된 서비스를 제공하기 위한 최적의 메커니즘 채택과 같은 핵심기술 개발과 지원을 하고자 함이다. 본 연구에서는 중고 수도미터를 이용하여 구경, 제작사, 사용연수 및 사용량별로 실험적으로 수행하였다. 연구결과 사용연수가 길어질수록 최소유량에 서의 오차가 "-" 방향으로 커지는 것을 확인하였다.