• Title/Summary/Keyword: Floor Device

Search Result 142, Processing Time 0.029 seconds

A Study on the Planning of the Computerized Tomography Unit in General Hospital (종합병원 컴퓨터단층촬영유니트의 건축계획에 관한 연구)

  • Yun, Woo Young;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.19 no.1
    • /
    • pp.59-66
    • /
    • 2013
  • Purpose: Although Computerized Tomography is one of the most useful diagnosis devices and Frequency of use by all kind of patient is higher than other device, it can be hardly to find out adequate data to planning of Computerized Tomography Unit. So questions have been raised about how to organize the unit. Methods: In order to suggest architectural guideline of Computerized Tomography Unit, expert interview, field survey and analysis to the floor plan have been conducted in this article. The area calculation was based on center line. Results: This article suggests a number of the guideline and the example of the planning which contains how to design Computerized Tomography Unit. Especially, in the case of the example on the planning, main points of the guideline is reflected. Implications: The result of this survey would be useful as a reference when the architect tries to design Computerized Tomography unit.

A Study on the Fire Protection System in the Stage (공연장의 소방시설 설치기준의 개선방안에 관한 연구)

  • 장상태;이영재
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.13-19
    • /
    • 1999
  • Currently, conventional fire prevention facility installation standard is based on the use and size of the domestic theaters. In the study, theaters with 1,900 seats were examined to suggest a suitable method to adapt a better fire preventing system. The proposed systems are as follow. - 100% of backup pressed-water outlet device, considering waterproof pressure for fire prevention facility at the top floor. - The supplement of the side wall type header and a large caliber outlet header for stage open sprinkler. - Subdividing a installation rule for special detector and implementing the latestdetector. - Installation of fire curtain for dividing stage area and auditorium area, and also the method of installation of fire curtain.

  • PDF

Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City (에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.

Modeling of triple concave friction pendulum bearings for seismic isolation of buildings

  • Yurdakul, Muhammet;Ates, Sevket
    • Structural Engineering and Mechanics
    • /
    • v.40 no.3
    • /
    • pp.315-334
    • /
    • 2011
  • Seismic isolated building structures are examined in this study. The triple concave friction pendulum (TCFP) is used as a seismic isolation system which is easy to be manufactured and enduring more than traditional seismic isolation systems. In the TCFP, take advantage of weight which pendulum carrying and it's geometry in order to obtain desirable result of seismic isolation systems. These systems offer advantage to buildings which subject to severe earthquake. This is result of damping force of earthquake by means of their internal constructions, which consists of multiple surfaces. As the combinations of surfaces upon which sliding is occurring change, the stiffness and effective friction change accordingly. Additionally, the mentioned the TCFP is modeled as of a series arrangement of the three single concave friction pendulum (SCFP) bearings. A two dimensional- and eight- story of a building with and without isolation system are used in the time history analysis in order to investigate of the effectiveness of the seismic isolation systems on the buildings. Results are compared with each other to emphasize efficiency of the TCFP as a seismic isolation device against the other friction type isolation system like single and double concave surfaces. The values of the acceleration, floor displacement and isolator displacement obtained from the results by using different types of the isolation bearings are compared each other. As a result, the findings show that the TCFP bearings are more effective devices for isolation of the buildings against severe earthquakes.

Control Performance of Friction Dampers Using Flexural Behavior of RC Shear Wall System (전단벽식 구조의 휨거동을 이용한 마찰감쇠기의 제어성능)

  • Chung, Hee-San;Moon, Byoung-Wook;Park, Ji-Hun;Lee, Sung-Kyung;Min, Kyung-Won;Byeon, Ji-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.856-863
    • /
    • 2008
  • High-rise apartments of shear wall system are governed by flexural behavior like a cantilever beam. Installation of the damper-brace system in a structure governed by flexural behavior is not suitable. Because of relatively high lateral stiffness of the shear wall, a load is not concentrate on the brace and the brace cannot perform a role as a damping device. In this paper, a friction damper applying flexibility of shear wall is proposed in order to reduce the deformation of a structure. To evaluate performance of the proposed friction damper, nonlinear time history analysis is executed by SeismoStruct analysis program and MVLEM(multi vertical linear element model) be used for simulating flexural behavior of the shear wall. It is found that control performance of the proposed friction damper is superior to one of a coupled wall with rigid beam. In conclusion, this study verified that the optimal control performance of the proposed friction damper is equal to 45 % of the maximum shear force inducing in middle-floor beam with rigid beam.

Actual conditions on the Living Environment of Small-scale Group-homes for the Elderly (고령자용 소규모 그룹홈의 생활환경 실태)

  • Kim, Hyun-Jin;An, Ok-Hee
    • Journal of the Korean housing association
    • /
    • v.19 no.3
    • /
    • pp.21-29
    • /
    • 2008
  • To investigate the actual conditions on the living environment of group-homes for the elderly and their living environment, 4 group-homes were surveyed. As the results, conditions of location for the group-home of the elderly looked positive, on the other hand, safety for criminal prevention, accessability and convenient facilities were not on level satisfied. The average area of each space in the group-home indicated that the bed room was $11.21\;m^2$, the living room $28.13\;m^2$, the kitchen $23.59\;m^2$, and the bath room had an integrated type of bath room and toilet $7.63\;m^2$. The physical environments of each space in the group-home were investigated, In bed room, door, windows and illumination were relatively good but safety was extremely inferior. Living room mostly looked good except the doorsill which needs refurbishment. In kitchen, cooking table, windows, illumination, ventilator were somewhat satisfactory but gas-warning device should have been installed. In addition, in bath room and toilet, location, door, window, illumination and finished material were satisfactory. But the stepped difference between the bath room and other space, safety-bar, emergency bell and floor heating system were seriously deteriorated and must be improved for the safety of the elderly. Conclusively, living environment of group-home for the elderly is mainly satisfactory but it was necessary to take a consideration for their safety.

Survey on the Uses of Heating-Cooling Facilitis.Accessory Devices and Residents' Evaluation in Cheju Province (제주도 지역 냉난방 설비.보조기구 사용실태와 거주자의 평가)

  • 김봉애
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.5
    • /
    • pp.239-248
    • /
    • 1997
  • to design nature-affinitive, reasonable and effcient thermal environment plannings and facilities, the holding patterns of heating-cooling facilities·accessory devices and residents' evaluation in Cheju Province were surveyed as well as residents' understanding for them. Major findings of this study are summarized as follows: 1) In the cooling system, the percentage of air-conditioner possessor was 19.4%, which was lower possessive rate than mainland's. The location of air-conditioner was mainly public area. That is, 55.3% of the location is livingroom, and the rest was Anbang. the general cooling accessory device was a fan. It was frequently used at the children's room and the dining room. The possessive patterns of air-conditioner depend on the characteristics of residents, such as the academic carrier and the average monthly income. Characteristics of house for air-conditioner possess depend on the location, house type, the size of floor space. 2) In the heating system, individual heating system reached to 57.3%. Heating accessory devices were oil stove and electric heating blanket. Only 32.2% of survey population were holders. 3) Residents preferred better ventilated room arrangement, which was characteristic of subtropical areas. 4) The preferred condition for heating-cooling facilities and accessory devices were strong solidity, less air pollution, and less noise.

  • PDF

Evaluation of Energy Consumption through Field Measurement at the Apartment Housing Unit Using Dynamic Flow Rate Balancing (실물실험을 통한 다이나믹 유량밸런싱 적용 공동주택 세대의 에너지소비량 평가)

  • Ryu, Seong-Ryong;Cheong, Chang-Heon;Cho, Hyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.15-20
    • /
    • 2016
  • Even though the control device of the heating system works well, insufficient water flow rates can degrade control performance and thermal comfort. The water flow rate should be adjusted appropriately to cope with the heating load of each zone. In order to solve these problems, a new balancing concept 'dynamic balancing' was proposed where a balancing valve opening can be automatically modulated according to the heating condition of the room. This study analyzed the effects of dynamic balancing upon indoor thermal environment and energy consumption in a radiant floor heating system through field measurement. Under part-load conditions, the use of a dynamic balancing is a more effective method to reduce energy consumption and to prevent a cavitation. Dynamic balancing is able to help boost the temperature of a room in the start-up period.

The Characteristics of Frank Lloyd Wright's Furniture Design focused on Organic Integration (유기적 통합의 개념으로 본 프랭크 로이드 라이트의 가구디자인 특성)

  • Moon Eun-Mi
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.115-122
    • /
    • 2006
  • The purpose of this study is to investigate the design principles of organic integration on furniture design by Frank Lloyd Wright. He consistently pursued organic principles in interior design, furniture and equipments. He insisted that every elements of a building can be integrated into architecture as if architecture can be a part of the nature. The study surveyed and analyzed the examples of furniture design in Wright houses from the viewpoints of spacial and formal integration as well as organic evolution. The study finds the characteristics of organic integration on furniture design as follows. He designed built-in furniture as an important part of the house, which seemed to grow up from the architecture design and a part of a building. He also designed and arranged free-standing furniture as spacial device in open floor plan. Moreover, furniture design repeated same geometry, modules, and proportion system of house design in order to integrate Into the building. In addition, material and color of furniture follow those of architecture. Wright's furniture design had changed from heavy forms in his early prairie houses to light and practical shapes in his Usonian period.

Suggestion of the Characteristics of Element Technology and the Standard Model through the Comparison of Domestic Zero-energy Houses (국내 에너지제로하우스 비교를 통한 요소기술 특성 및 표준 모델 제시에 관한 연구)

  • Lee, Chung-Kook;Lee, Jeong-Cheol;Kim, Sang-Su;Suh, Seung-Jik
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.27-35
    • /
    • 2012
  • Five zero energy house models developed in Korea for the purpose of the energy performance were compared and analyzed in the study. The standard passive house model applying common technology and efficient energy performance elements was proposed. Standard passive house 5 models have been developed commonly aiming at 100% energy saving, applying high-performance and high-efficiency exterior thermal insulation, using 3 low-e coated window system, and targeting average 0.65 ACH to enhance privacy. Energy recovery ventilators and dry and cold radiant heating floor has been partially applied. Eco-design techniques such as the awning device, heat insulating door, using natural light have been used. Solar and geothermal systems as the application of renewable energy technologies have been commonly applied. And fuel cells were applied to a partial model. The standard model based on common technical elements and average performance of each element and obtained from five model analysis has been proposed in the study.