• 제목/요약/키워드: Floating

검색결과 3,378건 처리시간 0.032초

바닥충격음 차단을 위한 뜬바닥 구조의 진동응답특성에 관한 실험적 연구 (An Experimental Study on the Vibration Response Characteristics of Floating Floor Systems for Heavyweight Impact Noise Reduction.)

  • 최경석;석원균;목지욱;신이섭;김형준;김정진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.227-228
    • /
    • 2023
  • A floating floor generally consists of mortar bed separated from the structural RC slab by a continuous resilient layer. It is known that the floating floors are a type of vibration-isolation system to improve the impact sound insulation performance. However, some researchers have demonstrated that the amplification of vibration response at a specific range of frequencies results in an increase in the impact sound level. This study carried out the forced vibration tests to obtain the frequency response function (FRF) of a floating floor compared with a bare RC slab. Test results shows that the additional peak occur in vibrational spectrum of the floating floor except natural vibration modes of the bare RC slab. This is because the relatively flexible resilient material and mass of the mortar bed offer an additional degree of freedom in the structural system. Therefore, it could be efficient for reduction of floor impact vibration and noise to control the additional mode frequency and response of floating floors.

  • PDF

경량 부유체의 운동 저감으로 안정성 증가방법에 관한 연구 (Method for Increasing Stability by Reducing the Motion of a Lightweight Floating Body)

  • 김선태;고재용;한유미
    • 해양환경안전학회지
    • /
    • 제29권4호
    • /
    • pp.407-416
    • /
    • 2023
  • 해양레저활동 인구증가 및 관련 산업의 급성장으로 인해 레저 선박을 접안하는 계류시설과 부유체를 기반으로 하는 해상부유식 펜션 등 레저시설 수요가 증가하고 있으며, 이러한 연안에서 사용되는 부유체는 대부분 경량 부유체로서 중량이 상대적으로 경량이므로 연안으로 유입되는 파(Wave)와 상재 하중에 의해 쉽게 경사가 발생하여 안정성이 낮아 안전사고가 빈번히 발생하고 있다. 이런 문제점에 대한 해결방안으로 부유체의 운동저감장치를 연구하여 알리고자 한다. 본 연구논문에서는 부유체에 운동저감장치(기압차를 이용한 운동저감장치)를 부착하여 운동저감효과를 부착하지 않은 부유체와 비교하는 방식으로 효과를 분석하였다. 효과분석은 전산해석시험으로 분석하여 부유체의 안정성 증가방법을 연구하고 그 효과를 검증해 보았다. 시험결과 분석결과 기압차를 이용한 운동저감장치를 부착한 부유체가 운동저감장치를 부착하지 않은 부유체보다 파랑에 대한 운동량이 저감되어 부유체의 안정성이 증가된 것으로 분석되었다. 이러한 부유체의 운동저감 장치는 무동력 선박뿐만 아니라 동력선, 반잠수식 선박에서도 유용하게 사용될 것으로 판단되어 다양한 분야에 적용하여 연구를 진행할 계획이다.

쌍동형 부유식 소파제의 소파성능에 관한 연구 (A Study on the Performance of Twin Hull Floating Breakwater)

  • 박노식;엄병섭
    • 한국해양공학회지
    • /
    • 제12권1호
    • /
    • pp.128-134
    • /
    • 1998
  • This study is carried out the theoretical studies on wave transmission and motions in waves of twin hull type floating breakwaters with the vertical and horizontal plate. The method of calculation is based on the three dimensional singularity distribution method. The results show that wave transmission is affected by heave motion. Twin hull type is designed by the use of the theoretical method and good performance of the developed floating breakwater is confirmed for longer wave period.

  • PDF

Floating Power Supply Based on Bootstrap Operation for Three-Level Neutral-Point-Clamped Voltage-Source Inverter

  • Nguyen, Qui Tu Vo;Lee, Dong-Choon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.3-4
    • /
    • 2011
  • This paper presents a survey of floating power supply based on bootstrap operation for three-level voltage-source inverters. The floating power supply for upper switches is achieved by the bootstrap capacitor charged during on-time of the switch underneath. Hence, a large number of bulky isolated DC/DC power supplies for each gate driver are reduced. The Pspice simulation results show the behavior of bootstrap devices and the performance of bootstrap capacitor voltage.

  • PDF

거주공간에서 뜬바닥 구조에 사용하는 동탄성계수 측정방법 (Determination of dynamic stiffness of materials used under floating floors in dwellings)

  • 정갑철;오양기;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.945-949
    • /
    • 2002
  • This part of specifies the method for determining the dynamic stiffness of resilient materials used under floating floors. Dynamic stiffness is one of the parameters that determine the sound insulation of such floors in dwellings. This part applies to the determination of dynamic stiffness per unit area of resilient materials with smooth surfaces used in a continuous layer under floating floors in dwellings

  • PDF

ANSI/IEEE Std. 754-1985에 의거한 부동소수점 연산기의 동작원리에 관한 연구 (A Study on the Behavior of Floating-Point Unit Conforming the ANSI/IEEE Std. 754-1985)

  • 김광욱;정태상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.788-790
    • /
    • 1999
  • A software implementation of floating-point addition and multiplication is presented. For this, the ANSI/IEEE standard for binary floating-point arithmetic is reviewed briefly. The architecture and behavior of the $Intel^{(R)}\;80{\times}87$ FPU is fully studied and basic algorithms for floating-point addition and multiplication are used for the implementation. Some examples and their verifications are also presented.

  • PDF

Numerical Analysis of Floating-Body Motions in Varying Bathymetry

  • Kim, Taeyoung;Kim, Yonghawn
    • International Journal of Ocean System Engineering
    • /
    • 제4권1호
    • /
    • pp.43-48
    • /
    • 2014
  • Varying bathymetry significantly affects on the wave propagation and motion response of floating body. Coupled-mode wave theory is adopted to describe the incident wave properly in varying region. The results of waves and motion response are compared to those from numerical wave tank, and the agreement is favorable. The sloped bottom is modeled and its effect on the floating body is discussed.

복합지지구조를 가진 뜬바닥 시스템 (II) (Floating Floor of Multi-supporting System ( II ))

  • 박영환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.293-295
    • /
    • 2004
  • In this research, we suggest the effective technique that the thickness of slab isn't increased, and considering proper shock absorbing material and supporting point, we make the floating floor which has multi-supporting system floating floor. As the result, it is effective in reduction of heavy weight system as well as one of light weight

  • PDF

복합지지구조를 가진 뜬바닥 시스템 (Floating Floor of Multi-Supporting System)

  • 박영환;정환돈;오호진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.928-931
    • /
    • 2003
  • In this research, we suggest the effective technique that the thickness of slab isn't increased, and considering proper shock absorbing material and supporting point, we make the floating floor which has multi-supporting system floating nut. As the result, it is effective in reduction of heavy weight system as well as one of light weight

  • PDF

Analysis on the viewing parameters of floating display system based on integral imaging

  • Kim, Joo-Hwan;Min, Sung-Wook;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.50-53
    • /
    • 2005
  • An analysis on the viewing parameters of floating display system based on integral imaging is introduced. A floating display system based on integral imaging is a three-dimensional display system which can display three-dimensional moving pictures with impressive feeling of depth. The analysis given in this paper will optimize the design of the floating display system for the specific application.

  • PDF