• Title/Summary/Keyword: Flicker-less

Search Result 24, Processing Time 0.024 seconds

Development of a New Automatic Image Quality Optimization System for Mobile TFT-LCD Applications (모바일 TFT-LCD 응용을 위한 새로운 형태의 자동화질 최적화 시스템 개발)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.1
    • /
    • pp.17-28
    • /
    • 2010
  • This paper presents a new automatic TFT-LCD image quality optimization system using DSP for the first time. Since conventional manual method depends on experiences of LCD module developers, it is highly labor-intensive and requires several correction steps providing large gamma correction error. The proposed system optimizes automatically gamma adjustment and power setting registers in mobile TFT-LCD driver IC to reduce gamma correction error, adjusting time, and flicker. It contains module-under-test (MUT, TFT-LCD module), PC installed with program, multimedia display tester for measuring luminance and flicker, and control board for interface between PC and TFT-LCD module. We have developed a new algorithm using 6-point programmable matching technique with reference gamma curve and applying automatic power setting sequence. Developed algorithm and program are generally applicable for most of the TFT-LCD modules. It is realized to calibrate gamma values of 1.8, 2.0, 2.2 and 3.0, and reduce flicker level. The control board is designed with DSP and FPGA, and it supports various interfaces such as RGB and CPU. Developed automatic image quality optimization system showed significantly reduced gamma adjusting time, reduced flicker, and much less average gamma error than conventional manual method. We believe that the proposed system is very useful to provide high-quality TFT-LCD and to improve developing process using optimized gamma-curve setting and automatic power setting.

A New Image Quality Optimization System for Mobile TFT-LCD (모바일 TFT-LCD를 위한 새로운 화질 최적화 시스템)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.734-737
    • /
    • 2008
  • This paper presents a new automatic TFT-LCD image quality optimization system. We also have developed new algorithms using 6-point programmable matching technique with reference gamma curve, and automatic power setting sequence. It optimizes automatically gamma adjustment and power setting registers in mobile TFT-LCD driver IC to reduce gamma correction error, adjusting time, and flicker. Developed algorithms and programs are generally applicable for most of the TFT-LCD modules. The proposed optimization system contains module-under-test (MUT, TFT-LCD module), control program, multimedia display tester for measuring luminance and flicker, and control board for interface between PC and TFT-LCD module. The control board is designed with DSP, and it supports various interfaces such as RGB and CPU. Developed automatic image quality optimization system showed significantly reduced gamma adjusting time, reduced flicker, and much less average gamma error than competing system. We believe that the proposed system is very useful to provide high image quality TFT-LCD and to reduce developing process time using optimized gamma-curve setting and automatic power setting.

  • PDF

Pulse Dual Slope Modulation for VLC

  • Oh, Minseok
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.4
    • /
    • pp.1276-1291
    • /
    • 2014
  • In the field of visible light communication (VLC), light-emitting diodes (LEDs) are used for transmitting data via visible light. In this study, we analyze pulse dual slope modulation (PDSM) as a means of delivering information in VLC. PDSM involves the modulation of symmetrical slope pulses to encode binary 0s and 1s, and owing to the moderately increasing and decreasing pulse shapes that are created, this method enables more spectral efficiency than the variable pulse position modulation (VPPM) technique currently adopted in IEEE 802.15.7. In particular, PDSM allows for the avoidance of intra-frame flicker by providing idle pulses in a spectrum-efficient way. A simple detection scheme is proposed for PDSMsignals, and its bit error rate (BER) is analyzed mathematically at varying slopes to validate the process through simulation. The BER performance of PDSM detection using dual sampling is compared to the performances of PDSM and VPPM using correlation detection. It is found that, when the probability of idle pulse transmission is less than 0.08 and higher than 0, the BER of dual sampling PDSM is lower than that of PDSM using correlation detection over the entire light intensity range.

Assessment of Sleep Deprivation and Fatigue Among Chemical Transportation Drivers in Chonburi, Thailand

  • Phatrabuddha, Nantaporn;Yingratanasuk, Tanongsak;Rotwannasin, Piti;Jaidee, Wanlop;Krajaiklang, Narin
    • Safety and Health at Work
    • /
    • v.9 no.2
    • /
    • pp.159-163
    • /
    • 2018
  • Background: Fatigue and sleepiness are inter-related and common among road transport drivers. In this study, sleep deprivation and fatigue among chemical transportation drivers were examined. Methods: A cross-sectional study surveying 107 drivers from three hazardous types of chemical production and transportation industries (nonflammable gases, flammable gases, and flammable liquids) was conducted. Data on sleep deprivation were collected using questionnaires of the Stanford Sleeping Scale and the Groningen Sleep Quality Scale. Fatigue was assessed using an interview questionnaire and a flicker fusion instrument. Results: Chemical drivers had a mean sleeping scale (Stanford Sleeping Scale) of 1.98 (standard deviation 1.00) and had a mean score of 1.89 (standard deviation 2.06) on the Groningen Sleep Quality Scale. High-risk drivers had higher scores in both the Stanford Sleeping Scale and the Groningen Sleep Quality Scale with a mean score of 2.59 and 4.62, respectively, and those differences reached statistical significance (p < 0.05). The prevalence of fatigue, as assessed through a critical flicker fusion analyzer, subjective fatigue question, and either of the instruments, was 32.32%, 16.16%, and 43.43%, respectively. Drivers who slept <7 hours and had poor sleep quality were found to have more fatigue than those who slept enough and well. Drivers who had a more sleepiness score resulted in significantly more objective fatigue than those who had a less sleepiness score. Conclusion: Sleep quality and sleeping hour can affect a driver's fatigue. Optimization of work-rest model should be considered to improve productivity, driver retention, and road safety.

The Relationship between Visual Stress and MBTI Personality Types (시각적 스트레스와 MBTI 성격유형과의 관계)

  • Kim, Sun-Uk;Han, Seung-Jo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4036-4044
    • /
    • 2012
  • This study is aimed to investigate the association between web-based visual stress and MBTI personality types. The stressor deriving visual stress is built by 14 vowels out of Korean alphabet as a content and parallel striples as a background on the screen, which is given to each subject during 5min. The dependent variable indicating how much human takes visual stress is the reduction rate of flicker fusion frequency, which is evaluated with visual flicker fusion frequency tester. The independent variables are gender and 8 MBTI personality types(E-I, S-N, T-F, and J-P), and hypotheses are based on human information processing model and previous studies. The results address that the reduction rate is not significantly affected by gender, S-N, and J-P, but E-I and T-F have significant influences on it. The reduction rate in I-type is almost 2 times as much as that in E-type and T-type has the rate 2.2 times more than F-type. This study can be applicable to determine the adequate personnel for jobs requiring less sensibility to visual stressors in areas that human error may lead to critical damages to an overall system.

A study on 7528W Class Fluorescent Lamp Ballast using a Piezoelectric Transformer by means of Onechip Microcontroller (Onechip Microcontroller에 의한 압전 변압기를 이용한 T5 28W급 형광등 전자식안정기에 관한 연구)

  • Hwang L. H.;Shin Y. H.;Cho S. R.;Jang E. S.;Cho M. T.;Ahn I. S.;Kim J. R.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.228-232
    • /
    • 2002
  • In this paper, In order to solve the problem is proposed using a new type of electronic ballast that the traditional magnetic ballasts operated at 50-60Hz have been suffered from noticeable flicker, high loss, large crest factor and heavy weight which is composed of rectifier, active power corrector, series resonant half bridge inverter, micro-controller and piezoelectric transformer for driving for driving T5 fluorescent lamp were manufactured. The proposed electronic ballast operated at high frequency (about 75kHz) shows a input power factor of more than 0.995, total harmonic distortion of less than $12\%$ and lamp current crest factor of less than 1.5, respectively. Output power and efficiency showed 28w and $85\%$, respectively. Accordingly, it is considered that the ballast using piezoelectric transformer can replace the typical electronic ballast.

  • PDF

Detection of Anormalies on the Power Line using the Instantaneous Frequencies (순간주파수를 이용한 전력선 신호의 이상현상검출)

  • Iem, Byeong-Gwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.544-548
    • /
    • 2006
  • The instantaneous frequency gives a frequency value at a time instance. Thus, it is natural to use the instantaneous frequency for detecting disturbances of voltage signal in power line. Various instantaneous frequency estimators are introduced. By applying to different types of disturbed signals, we show the estimators' ability to classify flickers. Also, the computational costs are compared between different instantaneous frequency estimators. The Prony's method (PRONY) and the modified covariance method (MCOV) need relatively smaller amount of calculation than the Teaser-Kaiser energy operator based estimator (DESA II). For an AM-FM modulated signal, the tracking performance of different instantaneous frequency estimators is also compared. Through simulation, it is shown that MCOV produces less variant frequency estimation values than DESA II and PRONY method.

Environment Implementation of Real-time Supervisory System Using Motion Detection Method (동작 검출 기법을 이용한 실시간 감시시스템의 구현)

  • 김형균;고석만;오무송
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.999-1002
    • /
    • 2003
  • In this study, embodied supervisory system that apply motion detection technique to small web camera and detects watch picture. Motion detection technique that use pixel value of car image that use in existing need memory to store background image. Also, there is sensitive shortcoming at increase of execution time by data process of pixel unit and noise. Suggested technique that compare extracting motion information by block unit to do to have complexion that solve this shortcoming and is strong at noise. Because motion information by block compares block characteristic value of image without need frame memory, store characteristic cost by block of image. Also, can get effect that reduce influence about noise and is less sensitive to flicker etc.. of camera more than motion detection that use pixel value in process that find characteristic value by block unit.

  • PDF

Implementation of Supervisory System for Motion Information per Blocks (블록별 모션정보에 의한 감시시스템의 구현)

  • 김형균;오무송
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.1
    • /
    • pp.74-79
    • /
    • 2004
  • In this study, embodied supervisory system that apply motion detection technique to small web camera and detects watch picture. Motion detection technique that use pixel value of car image that use in existing need memory to store background image. Also, there is sensitive shortcoming at increase of execution time by data process of pixel unit and noise. Suggested technique that compare extracting motion information by block unit to do to have complexion that solve this shortcoming and is strong at noise. Because motion information by block compares block characteristic value of image without need frame memory, store characteristic cost by block of image. Also, can get effect that reduce influence about noise and is less sensitive to flicker etc.. of camera more than motion detection that use pixel value in process that find characteristic value by block unit.

A Research on the Improvement of Visibility Using Low Deck Lighting in Bad Weather (악천후 시 낮은 도로조명을 이용한 도로 시인성 향상에 대한 연구)

  • Nam, Ki Ho;Kim, Chung Hyeok;Nam, Ki Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.186-193
    • /
    • 2020
  • We investigate a fog-detection CCT control system using low deck lighting as a solution to the forward visibility of pole-type street lamps employed on existing roads. The lighting standards were met with a light source that has less compared with those of pole-type street lamps. The results show that the transmission rate was increased by changing the color temperature by automatically recognizing fog in bad weather and minimizing the phenomenon of lighting. In addition, it was allowed to create a safer and more comfortable driving environment for drivers owing to flicker or light pollution of existing pole-type street lamps. As a result, if lighting is used at a lower level than pole-type street lamps, the accident rate caused by securing the driver's forward visibility can be reduced sharply and existing problems can be resolved.