• 제목/요약/키워드: Flexural member

검색결과 322건 처리시간 0.022초

철근콘크리트 보의 휨압축강도 및 변형률에 대한 크기효과 (Size Effect on Flexural Stress-Strain Relationship of Reinforced-Concrete Beams)

  • 김민수;김진근;김장호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.911-916
    • /
    • 2002
  • It is important to consider the effect of depth when estimating the ultimate strength of a concrete flexural member because the strength always decreases with an increase of member size. In this study, the size effect of reinforced concrete beam was experimentally investigated. For this purpose, a series of beam specimens subjected to 2-point bending load were tested. More specifically, three different depth (d=15, 30, and 60 cm) of reinforced concrete beams were tested to investigate the size effect. The shear-span to depth ratio (a/d=3) and thickness (20 cm) of the specimens were kept constant where the size effect in out-of-plan direction is not considered. The test results are fitted using least square method (LSM) to obtain parameters for modified size effect law (MSEL). The analysis results indicate that the flexural compression strength and ultimate strain decreases as the specimen size increases. Finally, more general parameters for MSEL are suggested.

  • PDF

세그멘탈 합성보의 휨 실험 (Flexural Tests on Post-Tensioned Segmental Composite Beam)

  • 김인규;설동재;유승룡
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.487-492
    • /
    • 2002
  • The interior portion of Gerber's beam are constructed with post-tensioned segmental composite beams in this study. A precast concrete member which is larger than the limits of domestic transportation regulation in weight, length, and volume is divided into three parts, transported separately, and erected with a composite member by post-tensioning in site. Static flexural loading tests are performed on Gerber's type frames which are consisted with 2.5m overhangs and 5m interior beams composited from three pieces. The connection of overhang to interior composite beam and beam to beam, and flexural performance of interior portion of Gerber's beam are examined thoroughly. All of the tests are ended with a compression failure of the interior composite beams over the design strength of homogeneous beams. The brittle connection failures or tensile failures with the failure of lower strand was not observed in any test frames.

  • PDF

콘크리트 충전 강관 부재의 휨거동에 관한 유한요소해석 (Finite Element Analysis of the Flexural Behavior of Concrete Filled Steel Tubes)

  • 강재윤;최은석;진원종;이정우;김병석;이흥수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.418-421
    • /
    • 2006
  • Appropriate analysis models for concrete-filled steel tube (CFT) subjected to bending moment were determined to assess flexural behavior of CFT member. Applying this model, finite element analyses was performed and compared against experimental data considering the compressive strength of in-filling material and the composite action between tube shell and in-filling core. Analysis results showed that the FE model proposed in this study is feasible for the analytical investigation of the flexural behavior of CFT member according to loading conditions, effect of compressive strength of various core materials and other design parameters.

  • PDF

고강도 콘크리트를 적용한 얇은 RC 판부재의 정적 강도 안전성 평가 (Structural Safety Evaluation for Static Strength of Thin Plate RC Member with High Strength Concrete)

  • 황훈희;박성용
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.69-75
    • /
    • 2017
  • Structural safety evaluation for static strength of thin plate RC member with high strength concrete is conducted in this study. Static strengths were predicted and compared with the experimental values. Predicted values were calculated by the evaluation formula based on the punching shear behavior and the yield line theory which can appear in the plate members. Static load tests were carried out for the specimens with high strength concrete and the test results were compared with the required performance in design. The comparison results show that the specimens with high strength concrete have sufficient structural safety for flexural and punching shear performance required in design. High strength concrete specimens exhibited excellent strength despite their small thickness. The range of concrete strengths applied in this study was about 60 MPa to 100 MPa.

FRP 모듈형 박스 부재의 연결 시스템에 관한 실험적 연구 (An Experimental Study on Connection System of FRP Modular Box Member)

  • 곽계환;장화섭;양동운;김호선
    • 한국농공학회논문집
    • /
    • 제51권4호
    • /
    • pp.29-36
    • /
    • 2009
  • This is a basic experimental study to apply FRP modular box member to a variety of construction structures exposed to flexural strength, such as a slab and a girder. Applying FRP modular box member to a real structure requires a large section. FRP box member was made into modular systems. Tests were conducted under various conditions in order to analyze jointing performance of the developed FRP modular box member as a large section. For the methods of jointing FRP modular box member, synthetic resins connection, mechanical connection, and a combination of both were used to test both length and breadth connection. As a result of the test, using urethane + two bolts + sheets was the most efficient method of connecting FRP modular box member. It is expected that the proposed joint system in this study will contribute to the increase of failure load and synthesis behavior of FRP modular box member.

Experimental and Numerical Assessment of the Service Behaviour of an Innovative Long-Span Precast Roof Element

  • Lago, Bruno Dal
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.261-273
    • /
    • 2017
  • The control of the deformative behaviour of pre-stressed concrete roof elements for a satisfactory service performance is a main issue of their structural design. Slender light-weight wing-shaped roof elements, typical of the European heritage, are particularly sensitive to this problem. The paper presents the results of deformation measurements during storage and of both torsional-flexural and purely flexural load tests carried out on a full-scale 40.5 m long innovative wing-shaped roof element. An element-based simplified integral procedure that de-couples the evolution of the deflection profile with the progressive shortening of the beam is adopted to catch the experimental visco-elastic behaviour of the element and the predictions are compared with normative close-form solutions. A linear 3D fem model is developed to investigate the torsional-flexural behaviour of the member. A mechanical non-linear beam model is used to predict the purely flexural behaviour of the roof member in the pre- and post-cracking phases and to validate the loss prediction of the adopted procedure. Both experimental and numerical results highlight that the adopted analysis method is viable and sound for an accurate simulation of the service behaviour of precast roof elements.

펄트루젼 구조용 휨부재의 국부좌굴 거동 (Local Buckling Behavior of Pultruded Structural Flexural Members)

  • 정재호;윤순종
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.147-151
    • /
    • 2003
  • In this study, we discussed the local buckling behavior of pultruded structural flexural members. Previous works were briefly reviewed and the local buckling behavior of orthotropic box-shape flexural members was discussed. The simplified form of equation for finding the width ratio of plate element of box-shape flexural members in which all plate components buckle simultaneously was proposed and the macro flow-chart for finding local buckling strength of pultruded flexural members was also suggested. To establish the design guide line for the local buckling of pultruded flexural members, further studies need to be performed as follows; the simplified form of solutions for finding the minimum buckling coefficient of orthotropic plate with various loading and boundary conditions including rotationally restrained boundary conditions, the simplified form of equation for calculating the coefficient of restraint provided by the adjacent plate elements.

  • PDF

콘크리트 충전 원형 강관을 이용한 터널강지보 합성부재의 휨거동 평가 (Evaluation of the Flexural Behavior of Composite Beam with Tunnel Steel Rib Support Using Circular Concrete Filled Steel Tube)

  • 마상준;최준혁
    • 한국강구조학회 논문집
    • /
    • 제29권5호
    • /
    • pp.353-359
    • /
    • 2017
  • 본 연구는 콘크리트 충전 강관을 터널의 강지보재로 활용하기 위한 것으로서, 콘크리트 충전강관 부재가 콘크리트 내에 매립되어 합성부재로 거동하는 경우에 대한 부재의 강도와 거동특성을 실험적으로 평가하였다. 이를 위하여 두 종류의 강관과 강관 내부를 일반콘크리트와 기포콘크리트로 충전한 경우, 콘크리트 슬래브에 철근으로 보강한 경우를 대상으로 총 6개의 보 시험체를 제작하였으며 정적 휨시험을 수행하였다. 그 결과, 일반콘크리트로 충전한 강관이 기포콘크리트로 충전한 것보다 더 높은 강도를 나타내었다. 그러나 강관 주변을 철근으로 보강한 경우 휨강도는 충전콘크리트의 종류보다 철근량의 영향이 더 큰 것으로 나타났다.

철근부식을 고려한 FRP Hybrid Bar 및 일반 철근을 가진 RC 보의 내력저하 평가 (Evaluation of Load Capacity Reduction in RC Beam with Corroded FRP Hybrid Bar and Steel)

  • 오경석;문진만;박기태;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권2호
    • /
    • pp.10-17
    • /
    • 2016
  • RC(Reinforced Concrete) 부재는 인장영역에서 보강재가 하중을 지지해야 하므로, 철근부식은 내구성 뿐 아니라 안전성에서도 매우 중요하다. 본 연구에서는 최근 개발된 FRP Hybrid Bar와 일반 철근을 매립한 RC 보부재를 제작하였으며, ICM(Impressed Current Method)를 적용하여 철근부식을 촉진시켰다. 기존의 이론식인 Faraday 법칙을 이용하여 부식량을 평가하였으며, 일반설계강도를 가진 콘크리트 보부재에 대하여 휨시험을 수행하였다. 일반 철근에서는 부식량이 4.9~7.8% 수준으로 평가되었으며 이에 따른 휨 저항능력은 -25.4~-50.8% 수준으로 감소하였다. FRP Hybrid Bar를 매립한 RC 보에서는 부식과 휨 저항 감소가 평가되지 않았는데, 이는 에폭시 도료로 코팅된 철근의 우수한 내부식성에 기인한다. 촉진 부식실험에서는 FRP Hybrid Bar의 우수한 내부식성 및 부착성능을 확인하였는데, 실용화를 위해서는 장기적인 침지를 통한 내구성 평가가 필요하다고 판단된다.

칼슘용출 열화 조건에서 광물질 혼화재를 사용한 RC부재의 휨 거동에 관한 실험적 연구 (An Experimental Study on Characteristics of Flexural Behavior in RC Member with Mineral Admixture under Calcium Leaching Degradation)

  • 이경종;최소영;최윤석;양은익
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권2호
    • /
    • pp.16-25
    • /
    • 2018
  • 콘크리트는 장기수명이 요구되는 구조물에 적합한 건설재료로 내구성이 우수하지만 장기간 지하수에 노출되어 발생하는 칼슘용출 현상에 대한 이해 및 이에 따른 RC 부재의 휨 거동 특성을 평가할 필요가 있다. 실험결과에 따르면, 광물질 혼화재는 RC 부재의 장기강도 개선에 효과적이지만, 칼슘용출이 발생하면 RC 부재의 항복하중 및 휨 강성이 감소하고 중립축깊이와 처짐량이 증가하는 것으로 나타났다. 따라서 칼슘용출에 의한 열화는 RC 부재의 성능 저하를 유발하므로 칼슘용출 환경에 노출되는 지하구조물에 광물질 혼화재가 적용될 경우에는, 광물질 혼화재 종류에 따른 최적 혼입 비율이 마련되어야할 것으로 사료된다.