• 제목/요약/키워드: Flexural Reinforcement Ratio

검색결과 281건 처리시간 0.026초

용접철망 콘크리트 벽체의 면내 휨거동 연구 (Inplane Flexural Behavior of Concrete Walls Reinforced by Welded Wire Fabric)

  • 김대중;김우;양지수;윤영호;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 봄 학술발표회 논문집
    • /
    • pp.136-141
    • /
    • 1993
  • 8 Wall specimens (1/2 scaled) used welded wire fabric (Ф=6mm) and ordinary deformed reinforcement(D6) of which their ultimate tensile strength were almost same were tested to investigate the inplane-flexural behavior. Test results show that : 1. The wall strength with welded wire fabric was 20% less than that with deformed bar. 2. The wall ductility ratio of welded wire fabric was 1/3 times than that of deformed bar, approximately. 3. It is recommened that lap splice of welded sire fabric should be avoided in critical fracture zone.

  • PDF

재하상태에 따른 탄소섬유보강공법의 휨 보강효과 (Flexural Rehabilitation Effect of Pre-loaded Reinforced Concrete Beams Strengthened by C.F.S)

  • 한복규;홍건호;신영수;조하나;정혜교
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.691-696
    • /
    • 1999
  • This paper is aimed to investigate flexural rehabilitation effect o pre-loaded reinforced concrete beams strengthened by carbon fiber sheet. Main Test parameters are reinforcement ratio and the magnitude of pro-loading and seven test beams are analyzed rehabilitation effect by carbon fiber sheet, load-deflection, failure mode, stress of reinforcing bar by the magnitude of pre-loading. Test results show that internal force was showed pre-loaded specimens lower than no-loaded specimens during rehabilitation and changing stiffness was showed in the same was and failure mode showed brittle failure from all specimens.

  • PDF

Application of silk composite to decorative laminate

  • Kimura, Teruo;Aoki, Shinpei
    • Advanced Composite Materials
    • /
    • 제16권4호
    • /
    • pp.349-360
    • /
    • 2007
  • Recently, natural fiber reinforced composite is attracting attention and considered as an environmentally friendly material. Usually cellulosic fibers are used to reinforce the composites, but some protein fibers such as silk and wool serve the same purpose. In this paper, we proposed a method of producing artistic composite from artistic fabric by using silk fiber reinforced biodegradable plastic, which is designated as 'silk composite', for reinforcement. In order to expand applications of the silk composite, we performed the compression molding of decorative laminates with woody material, which was selected as a core material, and examined the properties of molded decorative laminates with various content of the silk composite. Since plywood and medium-density fiberboard (MDF) are widely used for decorative laminates, we selected them as core materials. As a result, flexible decorative laminates with high flexural strength were obtained by compounding the silk composite with wood materials.

CFRP로 보강된 철근콘크리트 보의 거동 특성 (Behavior Characteristics of Reinforced Concrete Beam Strengthened with Carbon Fiber Reinforced Polymer Plate)

  • 박중열;황선일;조홍동;한상훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.125-131
    • /
    • 2003
  • 본 연구에서는 최근 구조물 보강을 위해 사용이 증가하고 있는 CFRP로 보강된 철근콘크리트 보의 휨거동 특성을 분석하였다. 실험변수로 보강길이와 폭, 철근비, 단부정착 여부 그리고 무보강 기준실험체의 예상 극한하중의 75%에 상응하는 사전하중 여부를 고려하였으며, 각각의 실험변수에 따른 영향을 분석하였다. 이를 위해, 총 20개의 철근콘크리트 보를 제작하고 실험을 수행하였으며, 실험변수에 따른 극한하중, 처짐, CFRP의 변형률 그리고 파괴모드의 변화 특성에 대해 연구하였다.

EFFECT OF CONCRETE STRENGTH ON FLEXURAL DEFLECTION OF HIGH-STRENGTH REINFORCED CONCRETE BEAMS

  • Inju Lee;Taewan Kim;Sung-Nam Hong;Jie Cui;Sun-Kyu Park
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.1313-1317
    • /
    • 2009
  • Deflections of Reinforced concrete structures must satisfy the permissible values and it is hard to predict the due to uncertainty of deflection of the reinforced concrete structures. Thus, many researchers have suggested a number of experimental equation of deflection against the uncertainty. In a specification, a procedure to evaluate flexure deflection using effective moment of inertia and moment-curvature relation is suggested. ACI offers a method using effective moment of inertia, which has been developed by Branson. Eurocode 2(EC2) suggests a procedure to evaluate deflection of reinforced concrete structure using moment-curvature relation. In this paper, a series of experiments were conducted on the singly reinforced concrete beams which have the same reinforcement ratio and different concrete strength. Therefore, the effect of the concrete strength on the deflection of the beams was analysed. The deflections obtained from the experiment were compared with the deflections calculated with ACI code and EC2.

  • PDF

탄소섬유시트로 보강된 철근콘크리트 보의 시공불량시 휨 거동에 관한 연구 (A Study on Flexural Behavior of Externally Reinforced R.C. Beam with Carbon Fiber Sheet : In Case of Constructional Deficiencies)

  • 박현정;이홍주;박성수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.95-102
    • /
    • 2002
  • The flexural behavior of the reinforced concrete (RC) structure upgraded by external reinforcements was examined in this study. It is well known that the incorporation of carbon fiber sheet (CFS) with concrete is one of the most effective ways to strengthen the RC structure. Complete bonding is required between CFS and concrete in order to make the RC structure provide its full function until the time the Re structures serve. Many studies have reported that construction deficiencies have caused the debonding of the CFS from concrete before the RC structure with CFS reaches its ultimate capacity. This research took a systematic look at the failure mechanism, macroscopic load-deformation characteristics, the maximum load applied, and maximum bending moment when construction deficiencies exist. The results of the experiment conducted were compared with theoretically derived values. In the future, the results of this investigation will help minimize the factors of construction deficiencies, which may occur when CFS is used to reinforce a RC structure. The experiment was manipulated with steel reinforcement ratio and piles of CFS on a total of 14 beams ($20cm{\times}30cm{\times}240cm$). The results showed that internal moment capacity increased even when construction deficiencies existed. However, RC structures with CFS in the field still contain a considerable level of potential risks.

GFRP 보강근으로 겹이음된 콘크리트 보의 보강비에 따른 거동특성 (Behavior of Reinforcement Ratio on Concrete Beams Reinforced with Lab Spliced GFRP Bar)

  • 최윤철;박금성;최현기;최창식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.67-76
    • /
    • 2011
  • 기존의 철근 콘크리트 구조물에서 나타나는, 극한 환경하에서의 철근의 부식 문제 때문에 GFRP 보강근으로 철근을 대체하고 있다. 최근 들어 GFRP를 보강근으로 사용한 보의 성능에 대한 해석적, 실험적 연구가 지속적으로 행해지고 있지만 아직 철근 콘크리트 보의 연구에 대한 수에 비하여 이에 대한 연구 결과는 매우 적어 신뢰성을 얻기 힘든 상황이다. 이에 본 연구에서는 겹침이음된 GFRP 보강근을 보에 적용하여 모멘트-처짐 관계에 대한 실험적 연구를 수행하였다. 실험 변수는 GFRP의 보강비와 피복 두께에 대한 것으로 총 6개의 GFRP 보강 콘크리트 보의 실험체가 제작되었다. 모든 실험체는 4000mm의 스팬을 가지고 있으며 12.7mm의 지름을 가지는 GFRP 보강근을 사용하였다. 보강근이 겹침이음된 부분에 일정한 모멘트가 작용하게 하기 위해 2점 가력 방식을 사용하였다. 실험 결과 보강근비의 증가에 따라 극한 하중의 크기가 증가하였다. 파괴 모드는 보강근비에 따라 매우 민감하게 변화하였으며 피복 두께는 인장측의 콘크리트의 탈락에 의해 최대 강도와 처짐량을 결정하는 요인이 되는 것으로 나타났다.

겹침이음 상세에 따른 철근콘크리트 교각의 내진성능에 관한 실험적 연구 (The Experimental Study on Seismic Performance of RC Bridge Columns with Longitudinal Steel Lap Splice)

  • 석상근;손혁수;정철호;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.553-558
    • /
    • 2001
  • Recent destructive seismic events demonstrated the importance of mitigating human casualties and serious property damages in design and construction of structures. The Korean Bridge Design Specifications (1992) adopted seismic design requirements based on the AASHTO specification, and minor modification was made in 2000. The longitudinal steel connection of reinforced concrete bridge column is sometimes practically unavoidable. The longitudinal reinforcement details affect seismic performance such as flexural failure and shear failure. This research aims to develop longitudinal steel connection details with confinement steel by experimental study for seismic performance of reinforced concrete bridge columns. Quasi-static test under three different axial load levels was conducted for 12 spiral column specimens. All the column specimens had the same aspect ratio of 3.5. The column specimens were transversely reinforced with spiral and with five different longitudinal steel connection. The final objective of this study is to suggest appropriate longitudinal reinforcement connection details for the limited ductility design concept and improve construction quality.

  • PDF

겹침이음 상세에 따른 철근콘크리트 교각의 내진성능 (Seismic Performance of RC Bridge Columns with Longitudinal Steel Lap Splice)

  • 이재훈;손혁수;석상근;정철호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.345-352
    • /
    • 2001
  • Recent destructive seismic events demonstrated the importance of mitigating human casualties and serious property damages in design and construction of structures. The Korean Bridge Design Specifications (1992) adopted seismic design requirements based on the AASHTO specification, and minor modification was made in 2000. The longitudinal steel connection of reinforced concrete bridge column is sometimes practically unavoidable. The longitudinal reinforcement details affect seisimc performance such as flexural failure and shear failure. This research aims to develop longitudinal steel connection details with confinement steel by experimental study for seismic performance of reinforced concrete bridge columns. Quasi-static test under three different axial load levels was conducted for 12 spiral column specimens. All the column specimens had the same aspect ratio of 3.5. The column specimens were transversely reinforced with spiral and with five different longitudinal steel connection. The final objective of this study is to suggest appropriate longitudinal reinforcement connection details for the limited ductility design concept and improve construction quality.

  • PDF

Shear Strength of Prestressed Steel Fiber Concrete I-Beams

  • Tadepalli, Padmanabha Rao;Dhonde, Hemant B.;Mo, Y.L.;Hsu, Thomas T.C.
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권3호
    • /
    • pp.267-281
    • /
    • 2015
  • Six full-scale prestressed concrete (PC) I-beams with steel fibers were tested to failure in this work. Beams were cast without any traditional transverse steel reinforcement. The main objective of the study was to determine the effects of two variables-the shear-span-to-depth ratio and steel fiber dosage, on the web-shear and flexural-shear modes of beam failure. The beams were subjected to concentrated vertical loads up to their maximum shear or moment capacity using four hydraulic actuators in load and displacement control mode. During the load tests, vertical deflections and displacements at several critical points on the web in the end zone of the beams were measured. From the load tests, it was observed that the shear capacities of the beams increased significantly due to the addition of steel fibers in concrete. Complete replacement of traditional shear reinforcement with steel fibers also increased the ductility and energy dissipation capacity of the PC I-beams.