The Experimental Study on Seismic Performance of RC Bridge Columns with Longitudinal Steel Lap Splice

겹침이음 상세에 따른 철근콘크리트 교각의 내진성능에 관한 실험적 연구

  • 석상근 (영남대학교 대학원 토목공학과) ;
  • 손혁수 (영남대학교 대학원 토목공학과) ;
  • 정철호 (영남대학교 대학원 토목공학과) ;
  • 이재훈 (영남대학교 토목공학과)
  • Published : 2001.05.01

Abstract

Recent destructive seismic events demonstrated the importance of mitigating human casualties and serious property damages in design and construction of structures. The Korean Bridge Design Specifications (1992) adopted seismic design requirements based on the AASHTO specification, and minor modification was made in 2000. The longitudinal steel connection of reinforced concrete bridge column is sometimes practically unavoidable. The longitudinal reinforcement details affect seismic performance such as flexural failure and shear failure. This research aims to develop longitudinal steel connection details with confinement steel by experimental study for seismic performance of reinforced concrete bridge columns. Quasi-static test under three different axial load levels was conducted for 12 spiral column specimens. All the column specimens had the same aspect ratio of 3.5. The column specimens were transversely reinforced with spiral and with five different longitudinal steel connection. The final objective of this study is to suggest appropriate longitudinal reinforcement connection details for the limited ductility design concept and improve construction quality.

Keywords