• Title/Summary/Keyword: Flash Method

Search Result 544, Processing Time 0.026 seconds

Panoramic Image Synthesis Using Flash and No-Flash Image Pairs (Flash 영상과 No-flash 영상을 이용한 파노라마 영상합성)

  • Ye, Sang-Myoung;Park, Rae-Hong
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.355-356
    • /
    • 2007
  • This paper proposes a new panoramic image synthesis method using flash and no-flash image pairs, which reduces undesirable artifacts. Generally, in panoramic images, it is difficult to determine to use a flash in indoor environment. A flash image has unwanted artifacts such as hot spots and tunnel effect whereas a no-flash image also has artifacts like glass reflection. We derive cross projection tensors using flash and no-flash image pairs and transform the gradient field of a no-flash image using them. The image reconstructed from the modified gradient provides enhanced results, which are applied to synthesis of panoramic images. The proposed method can provide a better panoramic image than the conventional method. Experimental results show the effectiveness of the proposed method.

  • PDF

Measurement of Flash Points for n-hexanol+n-butyric acid and n-butanol+propionic acid by Seta-flash Closed Cup Method (Seta-flash 밀폐식 방법에 의한 n-hexanol+n-butyric acid 계와 n-butanol+propionic acid 계의 인화점 측정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.76-80
    • /
    • 2014
  • The flash point is one of the most important physical properties used to determine the fire hazard of flammable liquid mixture and defined as the lowest temperature at which a liquid produces sufficient vapor to form a combustible mixture with air. The main purpose of this paper is to measure and predict the flash point of binary flammable miscible mixtures. The flash points for n-hexanol+n-butyric acid and n-butanol+propionic acid, were measured by using Seta-flash closed cup method. The experimentally derived data were correlated with the binary interaction parameters of the van Laar and NRTL equations through the optimization method. The flash points estimated by these correlations were compared with those calculated by the method based on Raoult's law. The optimization method were found to be better than the method based on the Raoult's law.

The Measurement and Prediction of Minimum Flash Point Behaviour for Flammable Binarry Solution Using Pensky-Martens Closed Cup Tester

  • Ha, Dong-Myeong;Choi, Yong-Chan;Lee, Sung-Jin
    • International Journal of Safety
    • /
    • v.9 no.2
    • /
    • pp.6-10
    • /
    • 2010
  • The flash point of liquid solution is one of the most important flammability properties that used in hazard and risk assessments. Minimum flash point behaviour (MFPB) is showed when the flash point of a liquid mixture is below the flash points of the individual components. In this paper, the lower flash points for the flammable binary system, n-decane+n-octanol, were measured by Pensky-Martens closed cup tester. This binary mixture exhibited MFPB. The measured flash points were compared with the values calculated by the Raoult's law and the optimization method using van Laar and UNIQUAC equations. The optimization method were found to be better than those based on the Raoult's law, and successfully estimated MFPB. The opimization method based on the van Laar equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the UNIQUAC.

A Flash Memory Management Method for Enhancing the Recovery Performance (복구 성능 향상을 위한 플래시 메모리 관리 기법)

  • Park, Song-Hwa;Lee, Jung-Hoon;Cho, Sung-Woo;Kim, Sang-Hyun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.13 no.5
    • /
    • pp.235-243
    • /
    • 2018
  • NAND flash memory has been widely used for embedded systems as storage device and the flash memory file systems such as JFFS2, YAFFS/YAFFS2 have been adopted by these embedded systems. The flash memory file systems provide the high performance and overcome the limitations of flash memory. However, these file systems don't solve the slow mount time problem when a sudden power failure happens. In this paper, we proposed a flash memory management method for enhancing the recovery performance. The proposed method manages the flash memory block type and stores the block type information at recovery image block. When file operations are occurred, our method stores the file information at the metadata block before and after the file operation. When mounting the flash memory, our method only scans the recovery image blocks and metadata blocks. The proposed method reduces the mount time by seeking the metadata block locations fast by using the recovery image blocks. We implemented the proposed method and evaluation results show that our method reduces the mount time 13 ~ 46 % compared with YAFFS2.

The Calculation and Measurement of Flash Point for Water+1-Propanol and Water+2-Propanol Using Closed Cup Aparatus (밀폐식 장치를 사용한 Water+1-Propanol 과 Water+2-Propanol의 인화점 측정과 계산)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.190-197
    • /
    • 2016
  • Flash point is the one of the important properties for the safe handling of inflammable liquid solution. In this paper, flash points of binary liquid solutions, water+1-propanol and water+2-propanol, were been measured by using Seta flash closed cup aparatus. Flash point was estimated using regression analysis method. Flash points were also estimated by the method based on Raoul's law and the method optimizing the binary parameters of van Laar equation. Experimental results were compared with the calculated results. The regression analysis method is able to estimate the flash point fairly well for water+1-propanol and water+2-propanol mixture.

Bubble Point Calculation using Experimental Flash Points of Binary Solutions (이성분계 용액의 인화점 실험값을 이용한 기포점 계산)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.39-44
    • /
    • 2016
  • Suitable design and operation of distillation process is very dependent on vapor-liquid equilibrium calculation. The usual calculation method is use binary interaction parameter. Flash points of n-propanol+n-butanol and 2-butanol+n-butanol were measured by Seta-flash closed cup tester. Experimental Flash points were compared with those calculated by the method based on Raoult's law and the optimization method using Wilson equation. The binary interaction parameters obtained by the optimization method are then used to calculate the bubble points of n-propanol+n-butanol and 2-butanol+n-butanol.

The Prediction of Lower Flash Points by Optimization Method

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • International Journal of Safety
    • /
    • v.8 no.2
    • /
    • pp.15-19
    • /
    • 2009
  • The flash point is the most widely used flammability property for the evaluation of the flammability hazard of combustible liquid mixtures. In this paper, the reported flash points for the the binary systems, ethylbenzene+n-butanol and ethylbenzene+n-hexanol were correlated by the optimization method. The optimization method based on the van Laar and Wilson equations were compared with the Raoult's law. The calculated values based on the optimization method were found to be better than those based on the Raoult's law.

A Comparison of Laser Flash and the Divided-bar Methods of Measuring Thermal Conductivity of Rocks (암석 열전도도 측정을 위한 Laser Flash Method와 Divided-bar Method 비교)

  • Oh, Jae-Ho;Kim, Hyoung-Chan;Park, Jeong-Min
    • Economic and Environmental Geology
    • /
    • v.44 no.5
    • /
    • pp.387-397
    • /
    • 2011
  • In this study, we conducted the study of the merits and demerits of the laser flash and the divided-bar methods for measuring the thermal conductivity of rocks and investigated applicability of the divided-bar apparatus which was developed by KIGAM. The laser flash method can measure thermal diffusivity, specific heat capacity, and thermal conductivity of rocks with even small thickness (< ~3 mm) in the high temperature range($25-200^{\circ}C$) in non-contact mode. For the laser flash method, samples must be uniform and homogeneous. In the case of the divided-bar method, the apparatus measures only thermal conductivity of rock samples at the room temperature. We measured thermal conductivities of 12 rock samples with low density and high porosity using two methods. In the laser flash method, there exist potential errors caused by the effect of pulse dispersion and reflection by various minerals and porosity in rock samples; the difference in thermal conductivity values measured on the front surface and the opposite surface ranges from 0.001 to 0.140 W/mK with the standard deviation of 0.003~0.089 W/mK, which seems to be caused by heterogeneity of rock samples. On the contrary, the divided-bar apparatus shows stable thermal conductivity measurements and relatively small measurement errors; the difference in thermal conductivity values, just as we applied to the laser frash method, is 0.001~0.016 W/mK with the standard deviation 0.001~0.034 W/mK. In turn, the divided-bar method can be applied to more thick samples that are more representative of bulk thermal conductivity.

The Measurement of Flash Point of Water-Methanol and Water-Ethanol Systems Using Seta Flash Closed Cup Tester (Seta Flash 밀폐식 장치를 이용한 Water-Methanol과 Water-Ethanol계의 인화점 측정)

  • Ha, Dong-Myeong;Park, Sang Hun;Lee, Sungjin
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.39-43
    • /
    • 2015
  • The flash point is the major property to characterize fire and explosion hazard of liquid mixtures. The flash point is the lowest temperature at which a liquid gives off enough vapor to form a flammable air-vapor mixture. The flash points of two aqueous mixtures, water-methanol and water-ethanol, were measured using Seta flash closed cup tester. A prediction method based on activity coefficient models, Wilson and UNIQUAC equations, was used to calculate the flash point. The calculated flash points were compared to the results by the calculating method using Raoult's law. The calculated values based on activity coefficients models were found to be better than those based on the Raoult's law.

Estimation of the Flash Points for n-Propanol+Formic acid System Using the Binary Parameters Optimization Method (이성분계 파라미터 최적화 기법을 활용한 n-Propanol+Formic acid 계의 인화점 추산)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.65-69
    • /
    • 2008
  • An accurate knowledge of the flash point is important in developing appropriate preventive and control measures in industrial fire protection. The lower flash points for the n-propanol+formic acid system were measured by Pensky-Martens closed cup apparatus. This binary mixture exhibited MFPB (minimum flash point behavior), which leads to the minimum on the flash point vs composition curve. The Raoult's law and optimization method using Wilson equation were used to predict the lower flash points and were compared with experimental data. The calculated values based on the optimization method were found to be better than those based on the Raoult's law.