The Measurement and Prediction of Minimum Flash Point Behaviour for Flammable Binarry Solution Using Pensky-Martens Closed Cup Tester

  • Ha, Dong-Myeong (Department of Occupational Health and Safety Engineering, Semyung University) ;
  • Choi, Yong-Chan (POSCO Engineering & construction Co. Ltd.) ;
  • Lee, Sung-Jin (Department of Clinical Laboratory Science, Semyung University)
  • Received : 2010.07.05
  • Accepted : 2010.12.02
  • Published : 2010.12.31

Abstract

The flash point of liquid solution is one of the most important flammability properties that used in hazard and risk assessments. Minimum flash point behaviour (MFPB) is showed when the flash point of a liquid mixture is below the flash points of the individual components. In this paper, the lower flash points for the flammable binary system, n-decane+n-octanol, were measured by Pensky-Martens closed cup tester. This binary mixture exhibited MFPB. The measured flash points were compared with the values calculated by the Raoult's law and the optimization method using van Laar and UNIQUAC equations. The optimization method were found to be better than those based on the Raoult's law, and successfully estimated MFPB. The opimization method based on the van Laar equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the UNIQUAC.

Keywords

References

  1. M. Vidal, W. J. Rogers and M. S. Mannan, "Prediction of Minimum Flash Point Behavious for Binary Mixtures", Process Safety and Environment Protection, Vol. 84(B1), pp. 1-9, 2006. https://doi.org/10.1205/psep.05041
  2. D. A. Crowl and J. F. Louvar, "Chemical Process Safety : Fundamentals with Applications", Englewood Cliffs, New Work, 1990.
  3. H. H. Liaw, T. P. Lee, J. S. Tai, W. H. Hsiao, M. H. Chen and T. T. Hsu, "Binary Liquid Solutions Exhibiting Minimum Flash-Point Behavior", J. of Loss Prevention in the Process Industries, Vol. 15, pp. 173-186, 2003.
  4. W. A. Affens and G. W. McLaren, "Flammability Properties of Hydrocarbon Solutions in Air", J. Chem. Eng. Data, Vol. 17, No. 4, pp. 482-488, 1972. https://doi.org/10.1021/je60055a040
  5. H. J. Liaw, Y. H. Lee, C. L. Tang, H. H. Hsu. and J. H. Liu, "A Mathematical Model for Predicting the Flash Point of Binary Solutions", J. of Loss Prevention in the Process Industries, Vol. 15, pp. 429-438, 2002. https://doi.org/10.1016/S0950-4230(02)00068-2
  6. S. Y. Kim and B. S. Lee, "A Prediction Model for the Flash Point of Binary Liquid Mixtures", J. of Loss Prevention in the Process Industries, Vol. 23, pp. 166-169, 2010. https://doi.org/10.1016/j.jlp.2009.07.008
  7. D. M. Ha, S. J. Lee. and M. H. Back., "Measurement and Estimation of the Lower Flash Points for the Flammable Binary System Using a Tag Open Cup Tester", Korea J. Chem. Eng., Vol. 24, pp. 551-555, 2007. https://doi.org/10.1007/s11814-007-0001-2
  8. D. M. Ha and S. J. Lee, "The Measurement and Estimation of Minimum Flash Point Behavior for Binary Mixtures Using Tag Open-Cup Tester", Journal of the Korean Institute of Gas, Vol. 12, pp. 50-55, 2009.
  9. B. E. Poling, J. M. Prausnitz and J. P. O'connell, "The Properties of Gases and Liquids", 5th Edition., McGrawHill, New York, 2001.
  10. D. M. Ha, S. J. Lee and Y. C. Choi, "Flash Points of Water+n-Propanol System Using Closed-Cup Measurement Apparatus", Journal of the KOSOS, Vol. 17, No. 4, pp. 140-145, 2003.
  11. H. Le Chatelier, "Estimation of Firedamp by Flammability Limits", Ann. Minmes, Vol. 19, pp. 388, 1891.
  12. J. Gmehing, U. Onken and W. ArIt, "Vapor-Liquid Equilibrium Data Collection", 1, Part1-Part7, DECHEMA, 1980.
  13. D. M. Ha and S. J. Lee, "Estimation of the Flash Points for n-Propanol+Formic acid System Using the Binary Parameters Optimization Method", J. of Korea Institute of Fire Sci. & Eng., Vol. 22, pp. 65-69, 2008.
  14. J. L. .Kuester and J. H. Mize, "Optimization Techniques with Fortran", McGraw-Hill, New York, 1973.
  15. Y. C. Choi, "Prediction and Measurement of Flash Points of Mixtures Using Closed Tester", M.S. Dissertation, Semyung University, Jecheon, Korea, 2003.
  16. D. M. Ha and S. J. Lee, "The Measurement and Estimation of the Lower Flash Points for tert-Pentanol+Propionic Acid and p-Xylene+Propionic Acid Systems Using Open-Cup Apparatus", J. of Korea Institute of Fire Sci. & Eng., Vol. 23, pp. 161-166, 2009.