• Title/Summary/Keyword: Flame detection

Search Result 197, Processing Time 0.03 seconds

Status of the Real-time Safety Monitoring System of Hydrogen Refueling Station According to the Operation (수소충전소 실시간 이중 모니터링 시스템 운영을 통한 안전성 향상)

  • Lee, Jin-Woo;Park, Jong-Hee;Kim, Dae-Hyun;Tak, Song-Su;Yang, Byung-Jo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.92-97
    • /
    • 2021
  • In accordance with the revision of the Enforcement Regulations of the High-Pressure Gas Safety Management Act in February 2021, from August 27, 2021, the operation status of safety devices such as gas leak detection and alarm devices, emergency shut-off devices and flame detectors installed at hydrogen vehicle charging stations can be monitored in real time. It is transmitted and operated by the computer system managed by Korea Gas Safety Corporations. We intend to share the results of statistical analysis of abnormal signals that have occurred along with the results of the monitoring system construction so that they can be used for the safety management of hydrogen refueling stations, and to seek future safety management directions.

Pistachio, Pomegranate and Olive Byproducts Added to Sheep Rations Change the Biofunctional Properties of Milk through the Milk Amino Acid Profile

  • Mucahit Kahraman;Sabri Yurtseven;Ebru Sakar;Aydin Das;Hamza Yalcin;Gulsah Gungoren;Mustafa Unal Boyraz;Ismail Koyuncu
    • Food Science of Animal Resources
    • /
    • v.43 no.1
    • /
    • pp.124-138
    • /
    • 2023
  • This study was carried out to determine the effects of adding pistachio shell (PIS), pomegranate hull (POM), and olive pulp (OP) to the diet on milk amino acid and fatty acid parameters in Awassi sheep. In the study, 40 head of Awassi sheep, which gave birth at least twice, were used as animal material. Sheep were fed a control diet without added byproducts (CON), rations containing PIS, POM, and OP. Milk amino acid profile was determined by liquid chromatography-tandem mass spectrometry, milk fatty acid gas chromatography-flame ionization detection device. There was a dramatic reduction in alanine, citrulline, glutamine, glutamic acid, glycine, leucine, ornithine and alphaaminoadipic acid in the research groups. In the PIS group, argininosuccinic acid, gammaminobutyric acid, beta-alanine and sarcosine; In the POM group, asparagine, gammaminobutyric acid, beta-alanine, and taurine; In the OP group, a significant positive increase was found in terms of alanine, histidine, gammaminobutyric acid, and taurine amino acids. The applications in the study did not have a statistically significant effect on the ratio of short, medium and long chain fatty acids in milk (p>0.05). In the presented study, it was determined that PIS, POM, and OP, which were added to the sheep rations at a rate of 5%, caused significant changes in the milk amino acid profiles. In this change in milk amino acid profiles, the benefit-harm relationship should be considered.

Fire Monitoring System for Traditional Markets based on Digital Twin-IoT Sensing (디지털 트윈 & IoT Sensing 융합 기반 전통시장 화재 모니터링 시스템)

  • Jung-Taek Hong;Kyu-Hyup Lee;Jin-Woo Song;Seo-Joon Lee;Young-Hee Chang;Soon-Wook Kwon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_3
    • /
    • pp.1251-1258
    • /
    • 2023
  • Traditional markets are infrastructure with facilities and characteristics of very high population density. Recently, arcades have been installed through traditional market modernization policies, and aging infrastructure has been repaired. However, gas and electrical facilities of traditional markets cannot be easily replaced because of its high density. And because regular inspections are not conducted, management of facilities is on very poor condition. In addition, when a fire occurs in a traditional market, the fire easily spreads to nearby stores and is likely to spread to a large fire because of a lot of highly flammable substances. Smoke detectors and heat detectors are installed in most traditional markets to monitor fires, but malfunctions are frequent due to the nature of smoke detectors and heat detectors, and network facilities are not properly maintained. Therefore, in this study, gas detection sensors and flame detectors are additionally installed in Gwangmyeong Traditional Market, and a digital twin-based traditional market fire monitoring system is implemented in conjunction with existing sensors in the market's 3D model. With this digital twin based fire monitoring system, we can reduce the malfunctions of fire detect sensors, and can easily guide the evacuation route.

Pretreatment method of urinary thiodiglycolic acid as metabolite of vinyl chloride (염화비닐의 요중 대사물질인 thiodiglycolic acid의 분석을 위한 전처리 조건)

  • Hong, Joo Youn;Kim, Chi Nyon;Jung, Jae Hoon;Chang, Jung Hwan;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.23-40
    • /
    • 1999
  • The analysis of thiodiglycolic acid in urine has been used as an index of biological exposure to vinyl chloride. Unfortunately thiodiglycolic acid has a strong hydrophilic character, because it has two carboxylic groups, so that it can only be extracted with organic solvent with a great difficulty. Underivatized thiodiglycolic acid tends to tail because of non-specific interaction with the inert support. Therefore, esterification is the obvious first choice for derivatization of thiodiglycolic acid, particularly for gas chromatography. In this study, the focus of interest is to compare two method of esterifications (methylation and silylation). Methylation is to make the methyl ester of thiodiglycolic acid by reaction with diazomethane. Silylation is to make the trimethylsilyl ester of thiodiglycolic acid by reaction with N-trimethylsily-ldiethylamine. The results and conclusions are as the following: 1. The detection limit (sensitivity) of methylated thiodiglycolic acid was $5.00{\mu}g/m{\ell}$ and silylated thiodiglycolic acid was $3.07{\mu}g/m{\ell}$ by gas chromatography with flame ionization detector. 2. The optimal liquid-liquid extraction of thiodiglycolic acid was as following: To each of the tubes, $15m{\ell}$ of urine, concentrated sulfuric acid (pH 1 - 2) and 5 gsodium sulfate were added. The samples was extracted three times with $5m{\ell}$ ethylacetate each time. 3. The methylated thiodiglycolic acid was more stable than silylated thiodiglycolic acid in extractional solvent which contained humidity. 4. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.07324 in methylated thiodiglycolic acid with external standard calibration, and 0.07033 in methylated thiodiglycolic acid with internal standard calibration. 5. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.10914 in silylated thiodiglycolic acid with external standard calibration, and 0.13602 in silylated thiodiglycolic acid with internal standard calibration. From the above results, the analysis of methylated thiodiglycolic acid was more sensitive (limit of detection) than silylated thiodiglycolic acid by gas chromatography. However, the methylated thiodiglycolic acid was stable in the humidity and was separated sharply on chromatogram. Also, analysis of methylated thiodiglycolic acid was more precise (pooled coefficient of variation for 4 days) than silylated thiodiglycolic acid. In conclusion, it is established that the analysis of methylated thiodiglycolic acid is appropriate for biological monitoring of exposure to vinyl chloride.

  • PDF

A Study on the Test and Installation Standards of the Video Fire Detector (영상화재감지기 시험과 설치기준에 관한 연구)

  • Lee, Jeong-Hyun;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.1-5
    • /
    • 2016
  • This research performed tests of Video Fire Detector and criteria of installation to make suggestions regarding the criteria that must be reflected in NFSC 203 by comparing the standards of FM Approvals, UL, ISO7240 and NFPA 72. FM Standard related to Video Fire Detector test has been classified as Smoke, Flame type, but the UL Standard has classified only as a Smoke type. This research examined 6 cases of fire phenomenon detection case in ISO 7240 and 3 cases in NFPA 72, respectively. There are 15 items required for the installation standard of a Video Fire Detector and each field standard is presented as a per installation method. To apply a Video Fire Detector, the pertinent items (the definition of term, detector's classification, structure and function among its test item) must be inserted. In addition, 7 items of the fire test, i.e., the sensitivity adjustment, prevent false alarm, ambient temperature test, the effective sensitivity and detection distance and viewing angle, aging test, flood test, must be applied to the actual test. For installation in the field, the operation environment and levels of illumination, and NFSC 203 must be set, and standards relevant to the sound system, indicators' installation distance, etc. need to be inserted.

Simultaneous Concentration and Determination of Several Trace Elements in Sea Water by Ce(OH)$_3$ Coprecipitation (Ce(OH)$_3$의 공침부선에 의한 해주중 몇 가지 미량원소의 동시 농축 및 정량)

  • Woo-Sik Sung;Hee-Seon Choi;Young-Sang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.3
    • /
    • pp.327-333
    • /
    • 1993
  • A method was developed for the determination of trace elements in seawater by precipitate flotation preconcentration and subsequent flame atomic absorption detection. In order to quantitatively coprecipitate trace ions such as Cd(II), CuI(II), Fe(III), Mn(II), Pb(II) and Pd(II), 2.0 ml of 1.0M cerium(III) solution was added to 1.0l of seawater and the pH was adjusted to 9.5 with 5.0 M sodium hydroxide solution while stirring with a magnetic stirrer. The precipitate was floated with the aid of surfactant solution (1.0 ml of 0.3% sodium oleate) by bubbling nitrogen gas through a porous (No. 4) fritted glass disk. The floats was collected in a small Erlenmeyer flask by suction. The washed precipitate was dissolved in 8.0 M nitric acid and marked with deionized water in the volumetric flask of 10.0 ml. The analyte was determined by measuring the atomic absorbances in 100-fold concentrated solution. Above all analytes in Kangnung (East Sea) and Kanghwado (West Sea) sea waters were found to be under the detection limit of this method. The recoveries of over 92% for all analytes spiked into seawater samples showed that this method was applicable to the analysis of real seawater.

  • PDF

Simultaneous Multicomponent Analysis of Preservatives in Cosmetics by Gas Chromatography (GC를 이용한 화장품 살균·보존제의 다성분 동시분석법)

  • Cho, Sang Hun;Jung, Hong Rae;Kim, Young Sug;Kim, Yang Hee;Park, Eun Mi;Shin, Sang Woon;Eum, Kyoung Suk;Hong, Se Ra;Kang, Hyo Jeong;Yoon, Mi Hye
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.1
    • /
    • pp.69-75
    • /
    • 2019
  • Preservatives of cosmetics is managed by positive list in Korea. Positive list requires a proper quantitative analysis method, but the analysis method is still insufficient. In this study, gas chromatography with flame ionization detector was used to simultaneously analyze 14 preservatives in cosmetics. As a result of method validation, the specificity was confirmed by the calibration curves of 14 preservatives showing good linearity correlation coefficient of above 0.9997 except dehydroacetic acid (0.9891). The limits of detection (LOD) and quantification (LOQ) of 14 preservatives were 0.0001 mg/mL ~ 0.0039 mg/mL and 0.0003 mg/mL ~ 0.0118 mg/mL, respectively, but they were 0.0204 mg/mL, 0.0617 mg/mL for dehydroacetic acid, respectively. The precision (Repeatability) of the values was less than 1.0%, but 7.1% for dehydroacetic acid. The Accuracy (% recovery) of 14 preservatives in cosmetics showed 96.9% ~ 109.2%. Finally, this method was applied to 50 cosmetics available in market. Results showed that the commonly used preservatives were chlorophene, phenoxyethanol, benzyl alcohol and parabens. However, the amount of the detected preservatives was within maximum allowed limits established by KFDA.

Melamine Concentration in Han River Basin and the in GAC Column Breakthrough Curve Model (한강수계 내 Melamine 농도검출과 GAC처리에서의 파과모델링)

  • Lee, Sang-Jung;Lee, Jai-Yeop;Han, Ihn-Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.717-722
    • /
    • 2011
  • Currently, melamine is being used variously in our lives such as resins, flame retardants, adhesive, laminate etc. And understandably sewer of stream of wastewater containing Melamine has also increased. GHS (Globally Harmonized System of Classification and Labelling of Chemicals) of EU safety guidelines says that it can cause cancer. Still, study on toxicity of Melamine is going on. In this research, melamine contamination level of the Han River and River Basin was analyzed by HPLC/UV. And the experiments of GAC adsorption were conducted and the model was studied. We collected the 3 same samples at the suburbs of Paldang Dam located in the relative upstream in Han River and Ttukseom amusement park, the downstream region and collected samples equally at the Hongreung stream, Wangsuk stream, Cheonggye stream among streams flowing into Han River and then measured Melamine concentration after purification. As a result, melamine was not detected at the suburbs of Paldang Dam and it was detected at Ttukseom amusement park, the downstream of it, in the concentration of $0.312{\mu}g/L$. The Wangsuk stream with $0.578{\mu}g/L$ highest Cheonggye stream and Hongreung stream was detected with each $0.197{\mu}g/L$ and $0.325{\mu}g/L$. Although the concentration was low in general, melamine detection could be checked at most point. In 1970, the world capacity of Melamine was estimated at 200,000 ton, with current production estimated to be 1,400,000 ton. Melamine of Han River and rivers flowing into Han River is present at low concentration but pollution will increase in the future due to increase of use. Depending on the size of activated carbon in the experiment were slightly different. But the breakthrough model is almost identical.

Simultaneous Analysis of Antimicrobial Three Straight Chain 1,2-alkanediols in Cosmetics by Gas Chromatography (가스크로마토그래피를 이용한 화장품 중 항균작용의 3종의 직쇄상 1,2-알칸디올류의 동시분석)

  • Lee, Hoo Seob;Lee, Sang Hun;Kim, Eun Juk;Chung, Cheol Hee;Pyo, Hyeong Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.1
    • /
    • pp.37-44
    • /
    • 2014
  • Preservatives such as paraben, phenoxyethanol, and chlorphene are commonly used in cosmetics thanks to cheap price and good antiseptic effect. Recently, consumers' concerns about their possible toxicity and skin irritation forced them to be replaced with straight 1,2-alkanediols. However, as the alkanediols may also irritate skin, limited amount of them should be used in cosmetics. Three 1,2-alkanediols including 1,2-pentanediol, 1,2-hexanediol, and 1,2-octanediol in cosmetics were analyzed simultaneously by gas chromatogrphy with flame ionization detector. As a result of method validation, the specificity was confirmed by the calibration curves of 1,2-pentanediol, 1,2-hexanediol, and 1,2-octanediol showing good linearity correlation coefficient of above 0.999 over the concentration range of $100{\sim}1,200{\mu}g/g$. The limit of detection (LOD) and quantification (LOQ) of 1,2-pentanediol, 1,2-hexanediol, and 1,2-octanediol were 31, 40, and $19{\mu}g/g$ and 98, 108, and $57{\mu}g/g$, respectively. The precision (Repeatability) of the amount in cosmetics showed less than 2.0%. Relative Standard Deviation (% RSD) and the Accuracy (% recovery) of the amount in cosmetics showed 99.3 ~ 103.3, 99.4 ~ 106.7, 97.5 ~ 107.3% respectively. As a result, simultaneous analysis of antimicrobial three 1,2-alkanediols in cosmetics were possible. This method can be utilized in accurate quantitative analysis of 1,2-alkanediols in cosmetics.

Catalytic decomposition of HDPE over Al-MCM-48 using TGA and Py-GC/FID (TGA와 Py-GC/FID를 이용한 Al-MCM-48상에서 HDPE의 촉매(觸媒) 열분해(熱分解))

  • Kim, Young-Min;Kim, Seung-Do;Park, Young-Kwon;Kim, Ji-Man;Jeon, Jong-Ki
    • Resources Recycling
    • /
    • v.15 no.5 s.73
    • /
    • pp.17-25
    • /
    • 2006
  • Al-MCM-48 was used as a catalyst to decompose high density polyethylene(HDPE). Catalytic activity of Al-MCM-48 was compared with those of Al-MCM-41, Beta, and ZSM-5. Catalytic decomposition rate over Al-MCM-48 was much higher than at of non-catalytic pyrolysis only. Compared to other catalysts, Al-MCM-48 revealed the little higher activation energy value. The progressive deactivation behavior of the catalysts has also studied. ZSM-5 and Al-MCM-48 showed slower deactivation rates than Al-MCM-41 and Beta. Pyrolysis coupled with gas chromatographic separation and flame ionization detection (Py-GC/ FID) was also performed to assess the characteristics of pyrolysis products. ZSM-5 gave a higher fraction of gaseous products ($C_1-C_4$). Al-MCM-41 and Beta produced mainly $C_5-C_{12}$ products. The selectivity to oil product ($C_5-C_{22}$) obtained with Al- MCM-48 is higher an that with the other catalysts employed in this study.