• 제목/요약/키워드: Fixed bed

검색결과 516건 처리시간 0.024초

Adsorption Characteristics of Toluene Vapor in Fixed-bed Activated Carbon Column (고정층 활성탄 흡착반응기에서 기상 톨루엔의 흡착특성)

  • Lim Jin-Kwan;Lee Song-Woo;Kam Sang-Kyu;Lee Dong-Whan;Lee Min-Gyu
    • Journal of Environmental Science International
    • /
    • 제14권1호
    • /
    • pp.61-69
    • /
    • 2005
  • Adsorption characteristics of toluene vapor, which is one of important source of volatile organic compounds (VOCs), by activated carbon were investigated using a fixed bed adsorption column. The operating parameters such as breakthrough curve, adsorption capacity, mass transfer zone (MTZ), and length of unused bed (LUB) were studied. The experimental results showed that the breakthrough time decreased with increasing inlet toluene concentration and gas flow rate. MTZ and LUB increased with the increase of inlet concentration, gas flow rate, and particle size of activated carbon. The adsorption capacity increased with the increase of inlet toluene concentration, while it decreased with increasing particle size. However, it was kept at constant value regardless of the increase of gas flow rate. Adsorption isotherm of toluene vapor could be represented by the Freundlich adsorption equation fairly well. From the adsorption experiments using some VOC gases such as toluene, xylene, butyl acetate. butanol and acetone, it was also found that the adsorption capacity was higher in the case of gas with higher boiling point and lower vapor pressure.

Adsorptive Characteristics of Benzene and Toluene on Activated Carbon (활성탄상에서 벤젠과 톨루엔의 흡착특성)

  • Park, Byung-Bae;Kim, Do-Su;Kim, Han-Su;Park, Yeong-Seong
    • Clean Technology
    • /
    • 제7권2호
    • /
    • pp.141-149
    • /
    • 2001
  • The effects of various factors such as adsorption temperature, interstitial velocity, species and concentration of adsorbates(benzene and toluene) and aspect ratio(L/D) on adsorption characteristics were investigated in a fixed bed with activated carbon. The breakthrough time in a fixed bed was decreased with the increasing of adsorption temperature, interstitial velocity and concentration of adsorbates. The interstitial velocity, concentration of adsorbates and adsorption temperature had influenced considerably upon the MTZ(mass transfer zone) and LUB(length of unused bed) obtained through the breakthrough curves, while aspect ratio(L/D) had smaller effect than former factors. Especially, the concentration of adsorbates among factors have the largest effect on MTZ and LUB. From comparison with the model isotherms, such as the Langmuir, Freundlich and Langmuir-Freundlich, the experimental isotherm data of benzene and toluene agreed farily well to three adsorption isotherm models.

  • PDF

The determinants of the Profitability of University Hospitals in Korea (대학병원 수익성에 영향을 미치는 요인 분석)

  • Yang, Jong-Hyun;Chang, Dong-Min;Suh, Chang-Jin
    • Korea Journal of Hospital Management
    • /
    • 제15권4호
    • /
    • pp.43-62
    • /
    • 2010
  • This study provides an evidence on the determinants of the profitability of university hospital by analyzing university hospital-level data set of hospital performance during the year 2007 (32 university hospitals in total). For the study, a multiple regression model is employed in which profitability index obtained from the DEA computations, operating margin to total asset and gross revenue are used as the dependent variables, and a number of hospital operating characteristics are chosen as the independent variables such as ownership type, location, bed size, period of establishment, bed occupancy rate, admission ratio of outpatients, patients per medical specialist, personnel cost per patient, liabilities to total assets, current ratio, fixed ratio, total asset turnover, medical assistance rate and public indicator. First, the results indicate that the bed occupancy rate and liabilities to total assets are positively and significantly associated with operating margin to total asset. Second, number of beds, the bed occupancy rate and number of patients per medical specialist are positively and significantly associated with operating margin to gross revenue. Third, the bed occupancy rate, number of patients per medical specialist, liabilities to total assets, total asset turnover are positively and significantly associated with profitability index revealed from DEA.

  • PDF

The Effect of Silicon-Alloying on the Characteristics of the Pyrolytic Carbonds Deposited in Tumbling Bed by CVD (Tumbling Bed에서 화학증착법에 의해 증착되는 열분해탄소의 특성에 미치는 Silicon-Alloying의 효과)

  • 윤영진;이재영
    • Journal of the Korean Ceramic Society
    • /
    • 제20권2호
    • /
    • pp.166-172
    • /
    • 1983
  • In this study the sillicon-alloyed isotropic pyrolytic carbon was deposited in the tumbling bed from the pyrolysis of propane and silicon tetrachloride and investigated whether the silicon-alloyed isotropic pyrolytic carbon deposited in this study was usable as bionaterial or not. The silicon-allyed isotropic pyrolytic carbon was varied by controlling the process variables such as propane con-concentration and the argon flow rate flowing in to the silicon tetrachloride bubbler at a fixed reaction bed tempera-ture of 120$0^{\circ}C$ a rotation of reaction tube of 40 rpm a bed particle weight of 7.5 g and a total flow rate of 21/min; the propane concentration was varied from 10 to 70 and the argon flow rate flowing into the silicon tetrachloride bubble from 0 to 1000 cc/min. The results show that the silicon-alloyed isotropic pyrolytic carbon was obtained at all conditions investigated, . And then the alloyed silicon content is rangion from 7 to 14.5 wt%. The density and deposition rate of deposited silicon-alloyed isotropic carbon increased axxording to silicon content and propane concentration. And the apparent crystal-size(Lc) of pyrolytic carbon is not changed with silicon content. The density and apparant crystallite size are respec-tively in the range of 1.94 to 2.06 and 20 to 25$\AA$ It is shown that the silicon-alloyed isotropic pyrolytic carbon ob-tained in this experiment is usable as biomaterial.

  • PDF

Effects of solid fuel combustion characteristics in various combustor types (다양한 종류의 연소로 형식에서 고체 연료 특성이 연소과정에 미치는 영향)

  • Choi, Jin-Hwan;Yang, Won;Lee, Sang-Deuk;Choi, Sang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제23회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.142-152
    • /
    • 2001
  • Three Lab-scale combustors of different types were made to observe some basic phenomena of fuel combustion in the combustors ; grate type combustor, rotary kiln and FBC. The aims were to introduce how to simulate the combustion behaviors in the real plants by utilizing the reduced apparatuses and characterize the combustors relating to some important parameters such as fuel size, water contents, bed temperature, rotating speed of kiln, flow rate. The mean carbon conversion time and the flame propagation rate were adopted for the quantitative analysis.

  • PDF

A Study on the Plan of Storge Space in Urban Housing -base on the volume calculation of storage space for clothes and bed-clothes in each rooms- (도시주택 수납공간 계획에 관한 연구 -침실별 의.침 구류 수납공간 체적산정을 중심으로-)

  • 손광제
    • Journal of the Korean Home Economics Association
    • /
    • 제27권4호
    • /
    • pp.73-84
    • /
    • 1989
  • The purpose of this study is to induce user to use storage equipment as fixed storage space in urban housing. The object of investigation is limited to the resident of detached and apartment house in Daegu, analysised the problems and their attitueds of using storage equipments amount of cloths and bel-clothes. On the basis of these recommended the optimum volume of storage space for clothes and bed-clothes by family types. Applied to the standard of detached house, the optimum volume of storage space for clothes and bed-clothes in each rooms are as following. 1) The volume of master room is ranged 7.34M3 and 8.65M3 the average is 7.97M3. 2) Children's room is ranged 1.18M3 and 3.26M3, the average is 2.51M3 under number of users and their age. 3) The aged room is calculated average 6.53M3.

  • PDF

Prediction of Service Life of a Respirator Cartridge by the Occupational Environment -Simulation of Breakthrough Curve for Respirator Cartridge and Sampling Tube- (작업현장의 환경조건에 따른 방독마스크 정화통의 수명예측 -모사에 의한 정화통과 샘플관의 파과시간-)

  • 김덕기;신창섭
    • Journal of the Korean Society of Safety
    • /
    • 제11권2호
    • /
    • pp.89-95
    • /
    • 1996
  • To predict the service life of an organic vapor respirator cartridge, the breakthrough curve of respirator was simulated using a fixed-bed adsorption model and compared with that of sampling tube. And the effects of bed porosity, length to diameter ratio and flow rate of the sampling tube were studied. The life time of respirator cartridge was increased with the decrease of particle size and bed porosity. And the breakthrough time of sampling tube was affected by the flow rate, however not by the length to diameter ratio. The 10% breakthrough time of the sampling tube was corresponded with that of cartridge.

  • PDF

Investigation of Solid Fuel Combustion Characteristics in Various Types of Combustors (다양한 종류의 연소로 내 고체 연료의 연소 특성 고찰)

  • Choi, Jin-Hwan;Yang, Won;Lee, Sang-Deuk;Choi, Sang-Min
    • Journal of the Korean Society of Combustion
    • /
    • 제9권3호
    • /
    • pp.1-9
    • /
    • 2004
  • This study is aimed to characterize the combustion behavior of solid fuel in the various types of the combustors: stoker, rotary kiln and fluidized bed type combustors. Three different types of reduced-scale combustors are introduced, and temperatures and flue gas compositions are measured for various fuel sizes, water contents, initial temperature, and air flow rates. In case of the rotary kiln combustor, effects of rotating speed of the combustor are also investigated. Mean carbon conversion time (MCCT) and flame propagation rate (FPR) are used for the quantitative analysis. It is revealed that the reaction rates of the fuel are significantly influenced by the fuel characteristics, type of the combustors and air flow rate. Major design parameters for each type of the combustors are summarized through the reduced-scaled model analysis.

  • PDF

An Analysis of Bed Change Characteristics by Bed Protection Work (바닥보호공 설치에 따른 하상변동 특성 분석)

  • Son, Ah Long;Kim, Byung Hyun;Moon, Bo Ram;Han, Kun Yeun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제35권4호
    • /
    • pp.821-834
    • /
    • 2015
  • This study presents the analysis of flow and bed change characteristics considering bed protection work built on the immediate downstream of weir to protect river bed from scouring. The study area is 37km reach from Hyunpoong station to Masuwon station including Hapcheon- Changryoung multi-function weir in the Nakdong river. CCHE2D model is calibrated and validated for evaluating the flow and bed change characteristics during Typhoon Kompasu in 2010. Three simulation conditions are set up: Case 1 is a natural channel without installation of weir. Case 2 involves an installation of weir in the natural channel. Case 3 involves an installation of weir with bed protection in the natural channel. Flood frequency (50, 100 and 200yr) is applied to each scenario to analyze the effects of bed protection work. While the sediment rate is increased in the downstream of fixed gate and sluice-type gate, river bed scouring rate is increased in the downstream of lift-type gate in Case 2 comparing with the results of Case 1. The river bed scouring is not occurred in the immediate downstream of weir (~30m) due to the effect of bed protection, but larger amount of sediment is occurred in the downstream of weir (60m~) which the bed protection is not installed comparing with the results Case 1. Through the results of simulation considering bed protection work, this study would be helpful to expect bed change and operate the weir as well as manage.

Study on Carbon Dioxide Control by Using Dry Sorbent in Fludized Bed (유동층에서 dry sorbent를 이용한 CO2 제어에 관한 연구)

  • Lee, Sang-Sup;Kim, Min-Choul;Yoo, Jeong-Seok;Moon, Gil-Ho;Oh, Kwang-Joong
    • Clean Technology
    • /
    • 제9권4호
    • /
    • pp.179-187
    • /
    • 2003
  • The technology of fluidized bed to use dry sorbent can be new technology that reduce the operating cost and make efficient operation. Therefore, this study investigated $CO_2$ control by dry sorbents with operating variables in a fluidized bed, compared with fixed bed for $CO_2$ adsorption capacity and pressure drop, and presented the $CO_2$ adsorption capacity of activated carbon, molecular sieve 5A, molecular sieve 13X, and activated alumina. As the results of this study, the basic data could be achieved for operation of fluidized bed process, and fluidized bed process presented relatively high $CO_2$ adsorption capacity and low pressure drop with the increase of gas velocity. In addition, molecular sieve 5A showed 1.1~3.0-fold later breakthrough point and 1.1~2.7-fold higher adsorption capacity than the other dry sorbents.

  • PDF