• Title/Summary/Keyword: Fixed base condition

Search Result 67, Processing Time 0.022 seconds

A Study on Pyrolysis of Styrene Dimer Fraction (SDF) (스티렌 이량체 유분의 열분해 연구)

  • Pei, Hai-Song;Kang, Yong;Cho, Deug-Hee;Choi, Myong-Jae;Lee, Sang-Bong
    • Applied Chemistry for Engineering
    • /
    • v.17 no.3
    • /
    • pp.321-326
    • /
    • 2006
  • Thermal degradation of styrene dimer fraction (SDF, main compound: 47 wt% of 1,3-diphenylpropane), 5~15% of total products produced during decomposition of waste expanded polystyrene (WEPS) was investigated. Reaction condition of $360^{\circ}C$, and 152 kPa to 202 kPa was an optimum for high pressure degradation. Under this operating condition, the yield of oil was 73.8% and the selectivities to Ben, Tol, EB, SM, and AMS were 0.4, 30.9, 15.0, 19.6, and 4.2%, respectively. Non-catalytic fixed bed continuous degradation was conducted at reaction temperatures of $510{\sim}610^{\circ}C$ and contact time ranges of 2~24 min, where the yield was increased by increasing of reaction temperature and contact time. A $Cr_2O_3$ catalyst showed the highest activity and SM yield among acid, base, and redox catalysts. The conversion of 74.6% and the yield of Ben, Tol, EB, SM, and AMS were 0.4, 21.6, 9.7, 17.9, and 3.5%, respectively at $560^{\circ}C$ and contact time of 24 min. It is thought that styrene is converted to EB and other secondary products throughout the formation of diradicals of styrene.

Entrepreneurship Education in Internet Business: Current Status & Future Direction (인터넷 창업교육 현황과 발전방안에 관한 연구)

  • Jeong, Jin-Su;Choi, Jong-In
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.3 no.1
    • /
    • pp.29-55
    • /
    • 2008
  • The objective of Starts-up education rears leading company that minimize a risk & connect them with successful idea. Internet Starts-up education is serviced in public & civil parts, it is insufficient to reach successful Starts-up support. This study is targeting on review the present condition of the Internet Starts-up education, research which it sees Internet Starts-up education actual condition investigation through investigation student of education satisfactorily and education contents and the plan to grope an Starts-up education progress coat problem and developmental plan it did. The current events point which has become research result escape first, age of the students of education, followed in educational background and, education motive and education experience presence education satisfactory boat song it appeared in these demand different, base grudge the form which is various it fixed and the education was demanded. Second, currently the department of pedagogy joining in establishment leader against the technical element which is advanced swip, the education reinforcement against an enterprise accomplishment ability back human factor, an enterprise propulsion environment and an enterprise item back enterprise environment element was demanded. Time after support and consulting, completion lifestyle community construction, completion lifestyle for item connection support and the trade name net after third, establishing an enterprise we the king, after toe ring back educating which carries on shoulder the importance of the civil official was embossed. The study which it sees led and like this investigation analysis the education progress for the successful support of the Internet Starts-up and time after connection setup construction it led and the plan which it will put out advancement of Starts-up education and it groped.

  • PDF

A Shape Control of Welded Joints to Improve Fatigue Strength (피로강도 향상을 위한 용접이음부의 형상제어에 관한 연구)

  • Kang, Chang Ib;Kook, Seung Kyu;Lee, Dong Uk
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.479-492
    • /
    • 2004
  • When U-ribs of steel deck plates are connected at the field, overhead welding should be done with backing strips. Misalignments may occur and lead to eccentric moments as well as high stress concentrations at welded joints. In this study, stress analyses and fatigue tests were carried out. Stress analyses for U-ribs' welded joints with backing strips were performed with different misalignments, root shapes, root gaps, and backing strip sizes. From the stress analyses, the stress concentration factors increased with increasing misalignments and root gaps. With the fixed misalignments and root gaps, the stress concentration factors obtained in the case of the semi-circle root shape were lower than those in the case of the right-angle root shape. It was verified that backing strip sizes have little influence on stress concentration factors. The fatigue tests for U-ribs' welded joints with backing strips indicated that increased misalignments shorten fatigue life drastically and cracks usually initiate at the root of the base metal and are propagated to the weld bead surface. Based on the results of the stress analyses, root-shape control methods were developed to mitigate stress concentration by changing welding condition control, radius curvature, and flank angle.

Spatial Extension of Runoff Data in the Applications of a Lumped Concept Model (집중형 수문모형을 활용한 홍수유출자료 공간적 확장성 분석)

  • Kim, Nam Won;Jung, Yong;Lee, Jeong Eun
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.9
    • /
    • pp.921-932
    • /
    • 2013
  • Runoff data availability is a substantial factor for precise flood control such as flood frequency or flood forecasting. However, runoff depths and/or peak discharges for small watersheds are rarely measured which are necessary components for hydrological analysis. To compensate for this discrepancy, a lumped concept such as a Storage Function Method (SFM) was applied for the partitioned Choongju Dam Watershed in Korea. This area was divided into 22 small watersheds for measuring the capability of spatial extension of runoff data. The chosen total number of flood events for searching parameters of SFM was 21 from 1991 to 2009. The parameters for 22 small watersheds consist of physical property based (storage coefficient: k, storage exponent: p, lag time: $T_l$) and flood event based parameters (primary runoff ratio: $f_1$, saturated rainfall: $R_{sa}$). Saturated rainfall and base flow from event based parameters were explored with respect to inflow at Choongju Dam while other parameters for each small watershed were fixed. When inflow of Choongju Dam was optimized, Youngchoon and Panwoon stations obtained average of Nash-Sutcliffe Efficiency (NSE) were 0.67 and 0.52, respectively, which are in the satisfaction condition (NSE > 0.5) for model evaluation. This result is showing the possibility of spatial data extension using a lumped concept model.

Numerical Analysis of Heat Transfer Characteristics of Ribbed Channels with Different Film Cooling Hole Position (필름 냉각을 위한 리브드 채널의 홀 위치에 따른 열전달 특성 수치 해석)

  • Park, Jee Min;Moon, Joo Hyun;Lee, Hyung Ju;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.69-76
    • /
    • 2018
  • The present study analyzed the effect of film hole position of 45 degree ribbed cooling channel on film cooling performance of gas turbine blades. We also investigated the influence of the ribs under the fixed blowing ratio. Three-dimensional numerical model was constructed and extensive simulation was conducted using the commercial code (Fluent ver. 17.0) under steady-state condition. Base on the simulation results, We investigated the cooling effectiveness, flow velocity, streamline, and pressure coefficient. Moreover, We analyzed the effect of cooling hole position on ejection of the secondary flow caused by the rib structure. From the results, It was found that internal flow of the cooling channel forms a vortex pair in the counterclockwise from the top side, and clockwise from the bottom side. For the channels with ribs, the vortex flow generated by the ribs caused a higher pressure difference near the hole outlet, resulting in at least 12% higher cooling effectiveness than the channel without ribs. Additionally, when the hole is located on the left side of the ribbed channel (Rib-Left), it can be found that the secondary flow generated by the ribs hits against wall surface near the hole to form a flow in the direction of the hole inclination angle. Therefore, It is considered that the region where the cooling gas discharged to the blade surface stays in the main flow boundary layer is wider than the other cases. In this case, The largest pressure coefficient difference was observed near the outlet of the hole, and as a result, the discharge of the cooling gas was accelerated and the cooling efficiency was slightly increased.

The Present Status Analysis of Interior Planning in a Fitness Center Inside an Apartment Complex (공동주택단지 내 휘트니스 센터 시설현황 분석에 관한 연구)

  • Cho Young-Youn
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.4 s.51
    • /
    • pp.87-94
    • /
    • 2005
  • Lately due to the sudden growth of the construction of an apartment complex in domestic market, many construction companies are eager to provide various public facilities to increase the apartment distribution rate. An introduction of a fitness center is popularized as a part of such development. There has been a continuing development in a private fitness based on analyzing the user's data. However a public fitness is quite different from the private in terms of a user's classification, preference rate, the pattern of use, and location which requires a different facility plan. Nevertheless, all these days a public fitness in an apartment house has been developed without a specific facility plan based on relevant materials. It is worried that such development would cause the facilities not to function as appropriate resident facilities and sink to idle ones. Therefore the purpose of this paper is to make the standard considered in facility planning in future and the base to guide an applying method. In the paper the present condition of fitness centers inside apartment houses has been compared to analyze the progress of the existing facilities and the appropriateness of the organization and the structure division. The result of the research shows that public resident facilities is not the place to perform passive role for fixed activities but one to form a community through the human relationship based on the facility. Therefore a fitness center inside the apartment complex have to be designed to provide service and leisure space as one of main community facilities for residents. To obtain this purpose, when choosing facilities of an apartment complex, first of all the residents' standard of living, apartment size, residents' distinction rate of age and sex, the needs of the times should be fully considered Secondly, the size of each facility space have to be decided based on the practical data analysis in facility use such as space preference, average staying time. Also, future living culture requires the change of the function and space according to the change of social values, so continuing research and data analysis are required to related to fitness center inside an apartment complex in order to present systematic approaching method and the paper will be expected to be a little step toward it.

Evaluation of tensile strength according to welding variables in GMA welding of SAPH440 (SAPH440재료의 GMA용접시 용접변수에 따른 인장 강도 특성 평가)

  • Kim, Won-Seop;Lee, Jong-Hun;LeeSeo, Han-Seop;Park, Sang-Heup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.133-138
    • /
    • 2019
  • This study evaluated the tensile properties of SAPH440, a hot-rolled steel for automotive structural applications, based on GMAW lap welding, the welding current, the welding voltage, and the feed rate. Tensile tests were performed according to the joint parameters of the GMAW process, for which specimens were fabricated according to KS B ISO 9018 by lap welding. The bead appearance was observed in each condition, and the weldability was evaluated by the tensile test. Higher the welding current resulted in a deeper weld, but the tensile strength was not significantly different from when the parameter was fixed due to the fracture of the base material. When the current was higher than the voltage, as in the case of a welding current of 200 A and welding voltage of 17 V, a large amount of spatter is generated, the welding is unstable, and the welded part breaks. Higher the voltage resulted in the bead not causing defects in general, and it also affected the weldability. If the current and voltage were too low, the welding was not performed normally, and the tensile strength could not be measured. However, as the current increased, the increase of the voltage and the feed rate did not affect the tensile strength.