• Title/Summary/Keyword: Fitting Model

Search Result 1,330, Processing Time 0.03 seconds

S-Domain Equivalent System for Electromagnetic Transient Studies PART I : Frequency Dependent Network Equivalent (전자기 과도현상 해석을 위한 S 영역 등가시스템 PART I : 주파수 의존 시스템 등가)

  • 왕용필
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.11
    • /
    • pp.632-638
    • /
    • 2003
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of frequency dependent equivalent. The s-domain rational function form of frequency dependent equivalent does not need refitting if the simulation time-step is changed in the electromagnetic transient program. This is because the s-domain rational function coefficients are independent of the simulation time-step, unlike the z-domain rational function coefficients. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper Presents the formulation for developing 1 Port Frequency Dependent Network Equivalent(FDNE) with the instantaneous term in S-domain and illustrates its use. This 1 port FDNE have been applied to the CIGRE Benchmark Rectifier test AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 port (FDNE) developed with Thevenin and Norton Equivalent network. The study results have indicated the robustness and accuracy of 1 port FDNE for electromagnetic transient studies.

Visual Object Tracking using Surface Fitting for Scale and Rotation Estimation

  • Wang, Yuhao;Ma, Jun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.5
    • /
    • pp.1744-1760
    • /
    • 2021
  • Since correlation filter appeared in the field of object tracking, it plays an increasingly vital role due to its excellent performance. Although many sophisticated trackers have been successfully applied to track the object accurately, very few of them attaches importance to the scale and rotation estimation. In order to address the above limitation, we propose a novel method combined with Fourier-Mellin transform and confidence evaluation strategy for robust object tracking. In the first place, we construct a correlation filter to locate the target object precisely. Then, a log-polar technique is used in the Fourier-Mellin transform to cope with the rotation and scale changes. In order to achieve subpixel accuracy, we come up with an efficient surface fitting mechanism to obtain the optimal calculation result. In addition, we introduce a confidence evaluation strategy modeled on the output response, which can decrease the impact of image noise and perform as a criterion to evaluate the target model stability. Experimental experiments on OTB100 demonstrate that the proposed algorithm achieves superior capability in success plots and precision plots of OPE, which is 10.8% points and 8.6% points than those of KCF. Besides, our method performs favorably against the others in terms of SRE and TRE validation schemes, which shows the superiority of our proposed algorithm in scale and rotation evaluation.

A study of the manual procedure of ocular prosthesis (의안의 제조 방법에 관한 연구)

  • Kim, Jai Min;Park, Dong Hwa;Yoo, Geun Chang;Kim, Soon Ae;Cho, Seung Kwon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.95-99
    • /
    • 2002
  • To investigate the manual procedure for custom fitting of ocular prosthesis and the cytotoxicity induced by extract solution of prosthetic eye, this study was performed. These procedures included the trial fitting of the wax model, impression molding, the an of iris color duplication, sclera mold made from the prosthetic wax model, scleral tints and vascular pattern, finishing and polishing. Inhibition of cell growth for extract solution was measured by MTT assay. Extract solution did not show the cytotoxicity. This study suggests that the manual procedure for custom fitting of ocular prosthesis is good for education of students.

  • PDF

GALAXY SED FITTING

  • Denis, Burgarella;Mederic, Boquien;Veronique, Buat;Laure, Ciesla;Yannick, Rhoelly
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.205-208
    • /
    • 2017
  • Modelling and fitting the spectral energy distribution (SED) of galaxies or regions of galaxies is one of the most useful methods available to the astronomer nowadays. By modelling the SEDs and comparing the models to the observations, we can collect important information on the physical processes at play in the formation and evolution of galaxies. The models allow to follow the evolution of the galaxies from their formation on. The versatility of code is crucial because of the diversity of galaxies. The analysis is only relevant and useful if the models can correctly reproduce this diversity now and across (as best as possible) all redshifts. On the other hand, the code needs to run fast to compare several million or tens of millions of models and to select the best (on a probabilistic basis) one that best resembles the observations. With this important point in mind, it seems logical that we should efficiently make use of the computer power available to the average astronomer. For instance, it seems difficult, today, to model and fit SEDs without a parallelized code. We present the new Python version of CIGALE SED fitting code and its characteristics. CIGALE comes in two main flavours: CIGALE Classic to fit SEDs and CIGALE Model to create spectra and SEDs of galaxies at all redshifts. The latest can potentially be used in conjunction with galaxy evolution models of galaxy formation and evolution such as semi-analytic ones.

TAH(Total Artificial Heart) Fitting Trial Supported by 4D Volume Visualization Technique (4차원 체적 가시화 기법을 이용한 인공심장의 Fitting Trial)

  • Lee, Dong-Hyuk;Kim, Jong-Hyo;Min, Byong-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.161-162
    • /
    • 1997
  • It is very useful to perform the surgery simulation before implanting TAH(Total Artificial Heart} in a patient. The space of chest and the shape of vessels are different from patient to patient. So, It is desirable to customize a TAH design to the anatomy structure of a patient. Several studies are performed to visualize and explain the 3D structure of heart. These studies are performed using 2-dimensional ref or mated images and simple measurement. Anatomy structure of a human heart is not so simple. It is 4dimensional structure ; 3-dimensional plus time, heart beating. 3-dimensional reconstruction schemes of medical images developed for about 10 years are usually categorized into two types of rendering technique ; surface rendering and volume rendering. Volume rendering is preferable in medical image processing field because this technique can be applied without considering the complexity of geometry and change of field of interest. The usable space in the chest of patient can be measured by 3D volume matching of patient trunk and TAH model. This space changes with time. In this research we have developed the 4-dimensional volume match program of patient and TAH model. 3-dimensional rendered set of volumes along time were used to simulate TAH fitting trial. The quantitative measurement from this simulation could be applied to customize TAH design.

  • PDF

Point Set Denoising Using a Variational Bayesian Method (변분 베이지안 방법을 이용한 점집합의 오차제거)

  • Yoon, Min-Cheol;Ivrissimtzis, Ioannis;Lee, Seung-Yong
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.5
    • /
    • pp.527-531
    • /
    • 2008
  • For statistical modeling, the model parameters are usually estimated by maximizing a probability measure, such as the likelihood or the posterior. In contrast, a variational Bayesian method treats the parameters of a model as probability distributions and computes optimal distributions for them rather than values. It has been shown that this approach effectively avoids the overfitting problem, which is common with other parameter optimization methods. This paper applies a variational Bayesian technique to surface fitting for height field data. Then, we propose point cloud denoising based on the basic surface fitting technique. Validation experiments and further tests with scan data verify the robustness of the proposed method.

Experimental Vibration Analysis of a Super-Structure Model Using Curve Fitting Method (곡선맞춤법을 이용한 선체상부구조 모델의 진동해석)

  • Oh, Chang-Geun;Je, Hae-Kwang;Park, Sok-Chu
    • Journal of Navigation and Port Research
    • /
    • v.26 no.3
    • /
    • pp.281-288
    • /
    • 2002
  • It might be true that both experimental and analytic techniques have been developed in the vibration analysis end engineering. It could not be said, however, that the experimental method has been also developed as much as analytic method, such as Finite Element Method One of the reason is that computation time becomes longer and that the solution often diverges depending on the choice of initial value in solving nonlinear equation. The equation in experimental modal analysis is usually composed of the nonlinear term of natural frequency and modal damping ratio, and the linear one of equivalent stiffness. In this study, the nonlinear terms were solved first, and then the linear term was obtained. The experimental modal parameters were estimated, applying the developed experimental modal analysis curve-fitting method to the super-structure model. In addition, the number of modes and modal damping ratio could be easily determined by the developed program with the application of graphical techniques and with easy handling button.

Effects of Fit Factor and Visual Acuity of Eyeglasses Wearers when Wearing Particulate Filtering Facepiece Respirators (안경착용자 방진마스크 착용 시 밀착계수와 착용시력에 미치는 영향)

  • Eoh, Won Souk;Shin, Chang Sup
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.105-115
    • /
    • 2020
  • This study compares the difference of fit factors (FF) and visual acuity according to masks and eyeglasses preferences for 54 participants. We the precautions and behaviors of discomfort when wearing masks of eyewear wearers. Contact lens discomfort and priority action of complaints was investigated Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA). We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity(VA) test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis(P=0.05) When wearing the mask preferentially, fit factor(FF) was high according to the step of glasses fitting parameter. on the other hand, when the glasses first choice, the visual acuity(VA) was high. there was no significant difference. In the case of fit factor (FF), mask first choice/ glasses first choice is OH (p=0.671/ p=0.332), VD (p=0.602/ p=0.571) and PA (p=0.549/ p=0.607). Visual acuity (VA), mask first choice/ glasses first choice is OH (p=0.753/ p=0.386), VD (p=0.815/ p=0.557) and PA (p=0.856/ p=0.562). The workers of workplace and office chose glasses but occupational health workers and students chose mask. In case of discomforts, it was suggested to remove the mask and tolerate discomforts. The main discomforts and usual action of lens were dryness, hyperemia, foreign body sensation, ophthalmodynia, decreased vision and glasses wearing. Therefore, it is necessary to develop a mask wearing method education program considering glasses fitting and develop a hybrid model that minimizes inconvenience when wearing glasses and a mask at the same time.

Improved Target Localization Using Line Fitting in Distributed Sensor Network of Detection-Only Sensor (탐지만 가능한 센서로 구성된 분산센서망에서 라인피팅을 이용한 표적위치 추정기법의 성능향상)

  • Ryu, Chang Soo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.362-369
    • /
    • 2012
  • Recently, a target detection based on a distributed sensor network has been much studied in active sonar. Zhou et al. proposed a target localization method using line fitting based on a distributed sensor network which consists of low complexity sensors that only report binary detection results. This method has three advantages relative to ML estimator. First, there is no need to estimate propagation model parameters. Second, the computation is simple. Third, it only use sensors with "detection", which implies less data to be collected by data processing center. However, this method has larger target localization error than the ML estimator. In this paper, a target localization method which modifies Zhou's method is proposed for reducing the localization error. The modified method shows the performance improvement that the target localization error is reduced by 40.7% to Zhou's method in the point of RMSE.

A Flexible Line-Fitting ICM Approach for Takbon Image Restoration (유연한 선부합 ICM 방식에 의한 탁본영상복원)

  • Hwang, Jae-Ho
    • The KIPS Transactions:PartB
    • /
    • v.13B no.5 s.108
    • /
    • pp.525-532
    • /
    • 2006
  • This paper proposes a new class of image restoration on the Ising modeled binary 'Takbon' image by the flexible line-fitting ICM(Iterated conditional modes) method. Basically 'Takbon' image need be divided into two extreme regions, information and background one due to its stroke combinations. The main idea is the line process, comparing with the conventional ICM approaches which were based on partially rectangular structured point process. For calculating geometrical mechanism, we have defined line-fitting functions at each current pixel array which form the set of linear lines with gradients and lengths. By applying the Bayes' decision to this set, the region of the current pixel is decided as one of the binary levels. In this case, their statistical reiteration for distinct tracking between intra and extra region offers a criterion to decide the attachment at each step. Finally simulations using the binary 'Takbon' image are provided to demonstrate the effectiveness of our new algorithm