• Title/Summary/Keyword: First hole

Search Result 443, Processing Time 0.029 seconds

A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION (임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구)

  • Kim Pyung-Il;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

A Baseline Study on Housing Cultures for Cross-Cultural Comparison between Korean- Australians and Australians(I) : An Analysis of Housing Cultures of Korean- Australian Families. (호주인과 호주 교민의 주거문화 비교를 위한 기초 연구(I) -호주 교민의 주생활 분석을 중심으로 -)

  • Lee Young-Shim;Lee Sang-Hae
    • Journal of Families and Better Life
    • /
    • v.23 no.2 s.74
    • /
    • pp.107-125
    • /
    • 2005
  • Each ethnic group has a different cultural background and has developed its own culture in the name of a tradition. The interaction between different cultures is ever increasing through the process of acculturation or culture contact The purpose of this study is to provide baseline information about domestic living of Korean immigrants in Australia and Australians for a larger cross-cultural study project. As the first step, the usage of domestic space and seating styles of 52 Korean households in Melbourne were analyzed. Ethnographic research was conducted, utilizing a questionnaire. The findings of this research are as follows: 1. The most popular type of Living-Dining-Kitchen arrangement was the one which the kitchen is separated from the living and dining area. The level of satisfaction was the highest when the living room, dining room, and kitchen were all separated. 2. A laundry room was indispensable for Koreans in Australia, and they wanted to dry laundry and do ironing in there. Most people were satisfied with the toilet separated from the bathroom A drain hole on the floor of the bathroom was not indispensable for most Korean-Australians. 3. Korean-Australians tend to engage in various activities in their individual rooms, and they estimated that the size of most rooms were small. They also wanted to renovate the house to expand the rooms. 4. The seating style of Korean-Australians was mostly chair-seating. Yet, they often made beds on the floor for guests, and made kimchi sitting on the floor. Also, when they were relaxing, they were using both chair-seating and floor-seating. 5. Korean-Australians were not very satisfied with the use of floor carpets because of the dust collected on the carpets, and the difficulty to clean. It may be related to their preferred floor seating style, as well. 6. Almost all Korean-Australians take off their shoes inside of the house for hygienic reasons. They had a shoes cabinet at the entrance inside of the house. 7. The most popular heating system was ducted heating. The level of satisfaction about this was moderate because hot air contains lots of dust and it makes rooms very dry. Many were using electric blankets and their desired heating system was Ondol (heated floor). 8. Korean-Australians thought that the living room was the most important place for the family, and believed it should be decorated well to entertain guests. They also pointed out that the lighting was not bright enough in general.

Scintigraphic Evaluation of Alveolar Bone Following Dental Implantation in Dogs (개에서 치아 임플란트 식립후 치조골의 신티그라피 평가)

  • Kim, Joong-hyun;Lee, Jae-yeong;Kim, Myoung-hwan;Lee, Won-guk;Kang, Seong-soo;Choi, Seok-hwa
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.2
    • /
    • pp.289-294
    • /
    • 2003
  • This study aimed to determine of osseointegration following dental implantation in the dog mandible using bone scintigraphy. Five mongrel dogs, weighing approximately 8.5 kg and averaging 1.8 years of age, without active periodontal disease were used. During the entire study period, all dogs were fed a soft commercial diet and water ad libitum to minimize functional loading of the implant. Titanium alloy implant systems 10 mm in length and 4 mm in diameter were chosen for insertion. Twelve weeks prior to implantation, the second and third left mandibular premolars in each dog were extracted for the dental implant insertion. Before the dental implantation procedures and 0, 4, 8, and 12 weeks after the insertions, clinical observation, radiography and bone scintigraphy were conducted. The scintigraphy was obtained using a large field of view gamma camera equipped with a paralled-hole, low-energy collimator about 3 hours after intravenous injection of Tc-99m-MDP (8 mCi/dog) to the dogs. There were not inflammation sign after insertion of dental implants on the mandible in dogs. Implants were slightly movable at the first and fourth weeks, and there was no mobility after 8 weeks. Twelve weeks after dental implantation, the bone uptake scintigraphy of peri-implant bone was similar to that of normal alveolar bone, indicating that peri-implant bone was completely regenerated by new bone. In conclusion, we recommend stable implant fixation with alveolar bone for the accurate and safe repair of teeth loot due to decacy, trauma or peridontal disease. Titanium alloy implants were optimal due to their biocompatibility.

A Study on Liver Cirrhosis Patients행 Sick Role Behavior (간경변증환자의 환자역할행위에 관한 연구)

  • 김옥수
    • Journal of Korean Academy of Nursing
    • /
    • v.15 no.1
    • /
    • pp.30-43
    • /
    • 1985
  • Liver cirrhosis is the common cause of death in Korea today. But, if liver cirrhosis Patients were treated in the early stage of the disease Process, they can have a chance to carry their daily lives with prescribed medical and nursing regimens. Each patient has different health beliefs that there is a different Sick Role Behavior in the process of treatment. In order to increase and control the desired patient's Sick Role Behavior, it is important for nurses to understand the health beliefs influencing Sick Role Behavior. The purpose of this study was to determine factors influencing Sick Role Behavior and provide objective and scientific data to health education, treatment and nursing care. The subjects for this study were 80 Liver Cirrhosis patients selected from in and out patients of the medical department of four University Hospitals in Seoul, Won Joo and Mok Po city. Data was collected from Sep. 18, to Oct. 15, 1984. The measurement tool was the questionaire that developed by the investigator from the literature review based on Health Belief Model. The data Collection was done by interview. Analysis of data was done by use Mean, S.D., ANOVA, Pearson Correlation Coefficient and Stepwise Multiple Regression. The result of study were as follows: 1. The significant influencing variables on the Liver Cirrhosis Patient's Sick Role Behavior in general characteristics were Sex, Marital Status, Educational levels, Family's income and Duration after diagnosis. 2. Between the Sick Role Behavior and Health Belief Model, a) The first hypothesis that the stronger degree of Health Motivation, the higher degree of Liver Cirrhosis Patient's Sick Hole Behavior was supported (r=0.7892, p=0.0000). b) The second hypothesis that the higher degree of perceived susceptibility, the higher degree of Liver Cirrhosis Patients' Sick Role Behavior was supported (r=0.6383, p=0.0000) c) The third hypothesis that the higher degree of perceived severity, the higher degree of Liver Cirrhosis Patients' Sick Role Behavior was supported (r=0.5869, p=0.0000). d) The fourth hypothesis that the higher degree of perceived benefit, the higher degree of Liver Cirrhosis patient's Sick Role Behavior was supported (r=0.7535, p=0.0000). e) The fifth hypothesis that the lower degree of perceived barrier, the higher degree of Liver Cirrhosis Patient's Sick Role Behavior was supported(r=-9.7709, p=0.0000) f) The sixth hypothesis that the higher degree of knowledge in Disease, the higher degree of Liver Cirrhosis patients'lck Role Behavior was supported (r=0.7538, p=0.0000), g) In the correlation among variables, it was found positive correlation except that perceived barrier was negatively correlated. In the Stepwise Multiple Regression and Independent Variables, the factor“Health Motivation”could account for Sick Role Behavior in 62.28% of the Sample (F=128. 786, p<0.01). When the factor“perceived barrier”is added to this, it account for 70.38% of Sick Role Behavior (F=93.479, p <0.01) and the factor“knowledge in disease”is also included, it account for 74.78% of Sick Role Behavior (F=75.131, p <0.01). Finally, when the factor“perceived susceptibility”is included, it account for 75.03% of Sick Role Behavior (F=56.329, p <0.01).

  • PDF

A Method for Application of Ammonium-based Pretreatment Solution in Preparation of Copper Flakes Coated by Electroless Ag Plating (구리 플레이크의 무전해 은도금에서 암모늄계 구리 전처리 용액의 적용법)

  • Kim, Ji Hwan;Lee, Jong-Hyun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.4
    • /
    • pp.57-63
    • /
    • 2015
  • In order to prepare a low-cost conductive filler material possessing improved anti-oxidation property, Ag-coated Cu flakes were fabricated and the effects of an applying method of ammonium-based pretreatment solution on the Cu flakes were analyzed. The pretreatment solution was used to remove the surface oxide layer on Cu flake. During a single-stage pretreatment process, hole-shaped defects were formed on the flake surface during the pretreatment after 2 min, and the number and size increased in proportion to the pretreatment time. In the case that Ag plating solution was injected in the pretreatment solution after the pretreatment for 2 min, the defects were also formed during Ag plating. In contrast, the defects tremendous decreased in the case that the pretreatment solution was removed after the first pretreatment for 2 min and the Ag plating proceeded after the second pretratment using a low concentration pretreatment solution. As the final result, the 15 wt% Ag-coated Cu flake sample which was fabricated using the single-stage pretreatment oxidized at $166^{\circ}C$, but the sample fabricated by the double-stage pretreatment oxidized at $224^{\circ}C$, indicating definitely improved anti-oxidation property.

Tri-Band Folded Monopole Antenna Design with MNG Single Cell Metamaterial Loading (MNG 단일셀 메타매질 부하를 갖는 삼중대역 폴디드 모노폴 안테나 설계)

  • Lee, Young-Hun
    • Journal of IKEEE
    • /
    • v.22 no.1
    • /
    • pp.127-135
    • /
    • 2018
  • This paper was studied the tri-band folded monopole antenna design with Mu-negative metamaterial unit cell, which operates at 700 MHz UHD broadcast band and 2.45 GHz/5 GHz WiFi band. The MNR metamaterial is fabricated by forming a capacitor on the backside of the antenna substrate and connecting it to the ground plane through a strip line and a via hole so that a single cell can operate in the MZR (Mu zero resonator). Through this, the resonance point can be controlled to resonate in the zero mode in 700 MHz band, and the bandwidth is improved. Experimental results show that the 10dB bandwidth and gain are 309 MHz (41.2%) and 5.298 dB at the first resonance point, and the 10dB bandwidth and gain at the second resonance point are 821.9 MHz (33.5%) and 2.7840 dB respectively. At the third resonance point, the gain and bandwidth were 1.1314 GHz (20.6%) and 2.9484 dB respectively. We confirmed that the resonance point with theoretical value is in agreement with experimental value. And the radiation pattern is generally omnidirectional, and it has been confirmed that the radiation pattern is good in both forward and backward directions at 0.75 GHz and 2.45 GHz, and has a radiation pattern with multiple lobes at 5.5 GHz.

Effect of extraction socket granulation tissue graft on the regeneration of horizontal furcation defect (발치와의 육아조직 이식이 치근이개 결손부의 재생에 미치는 영향)

  • Oh, Mok-Hoon;Han, Soo-Boo;Son, Sung-Heui;Yang, Seung-Min;Ko, Jae-Seung
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.3
    • /
    • pp.735-751
    • /
    • 1996
  • An ultimate goal of periodontal therapy is to stop the disease process and to regenerate a functionally-oriented periodontium destroyed as a result of periodontal disease. The purpose of this study was to observe the effect of grafting granulation tissue obtained from extraction socket on the regeneration of horizontal furcation defect. Six dogs were used in this study. All mandibular first and third premolars were extracted. At 2, 3, and 5 days after extraction, tissues were obtained from extraction socket of 1 mongrel dog and examined by light microscope. Granulation tissue obtained at 5 days after extraction was chosen as the graft material. Five days later, horizontal furcation defects were created surgically at mandibular second and fourth premolars in the right and left side of the 5 beagle dogs. The entrance area of the artificially prepared "key hole" defects were about $3\;4mm^2$. By random selections, 2 exposed furcation defects were grafted with granulation tissue obtained from extraction socket as experimental group and 1 furcation defect was as control. The flaps were replaced to their original position and sutured with 4-0 chromic cat-gut. Three dogs were sacrificed 4 weeks and two dogs 8 weeks after surgery, and the prepared specimens were examined by light microscope. At 4 weeks, furcations were filled with epithelial lining and fibrous connective tissue infiltrated with chronic inflammatory cells. New bone formation was observed in all groups. Only experimental group showed new cementum formation. At 8 weeks, new cementum, functional arrangement of new PDL fiber, root resorption, and some ankylotic union of newly formed alveolar bone and root surface were observed in all groups. Experimental group showed that epithelial downgrowth was inhibited and new bone formation was more active compared to control. The success rate of the furcation defect healing was higher in experimental group than control. These results suggested that grafting of granulation tissue obtained from extraction socket which combined with reconstructive periodontal flap surgery may promote periodontal regeneration of horizontal furcation defect.

  • PDF

FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO PLATFORM WIDTH OF FIXTURE (임플란트 고정체의 platform의 크기에 따른 유한요소법적 응력분석)

  • Chung Kyung-Min;Chung Chae-Heon;Jeong Seung-Mi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.674-688
    • /
    • 2003
  • Statement of Problem : With increasing demand of the implant-supported prosthesis, it is advantageous to use the different platform width of the fixture according to bone quantity and quality of the patients. Purpose : The purpose of this study was to assess the loading distributing characteristics of two implant designs according to each platform width of fixture, under vertical and inclined loading using finite element analysis. Material and method : The two kinds of finite element models were designed according to each platform width of future (4.1mm restorative component x 11.5mm length, 5.0mm wide-diameter restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction, 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction and 200N at the buccal cusp in a 300 transverse direction individually Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. Results : The stresses were concentrated mainly at the cortex in both vertical and oblique load ing but the stresses in the cancellous bone were low in both vertical and oblique loading. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading. Increasing the platform width of the implant fixture decreased the stress in the supporting bone, future and abutment screw. Increased the platform width of fixture decreased the stress in the crown and platform. Conclusion : Conclusively, this investigation provides evidence that the platform width of the implant fixture directly affects periimplant stress. By increasing the platform width of the implant fixture, it showed tendency to decreased the supporting bone, future and screw. But, further clinical studies are necessary to determine the ideal protocol for the successful placement of wide platform implants.

Design and Verification of Shear Buckling Test Fixture for Composite Laminate (복합재 적층판의 전단좌굴시험을 위한 치구 설계 및 검증)

  • Park, Sung-Jun;Ko, Myung-Gyun;Kim, Dong-Gwan;Kim, Sang-Kuk;Moon, Chang-Oh;Kweon, Jin-Hwe;Choi, Jin-Ho
    • Composites Research
    • /
    • v.27 no.4
    • /
    • pp.158-167
    • /
    • 2014
  • Final goal of this research is to establish the database for correlation factors which connects the test and analysis results of shear buckling allowables for composite plate. To accomplish the goal, extensive test and analysis works are required. In this paper, as the first step, a frame-type fixture for shear buckling test was designed and validated through the test and analysis. Final configuration of the fixture were determined via parametric study on the effect of specimen size, cross-sectional dimensions, and number of fastening bolts on the shear buckling load. Results of the study showed the designed frame-type fixture successfully induces the shear buckling of composite plate. However, there were deviations between the test results and analysis results for ideal case under pure shear load, which were mainly caused by the difference in plate sizes for both cases. The difference were larger in the plates with larger hole and simply supported boundary condition. It is concluded from the results that while the designed fixture can be used for the clamped plates with acceptable accuracy, it shows larger difference in the simply supported plates.

Characteristics of SiO2/Si Quantum Dots Super Lattice Structure Prepared by Magnetron Co-Sputtering Method (마그네트론 코스퍼터링법으로 형성한 SiO2/Si 양자점 초격자 구조의 특성)

  • Park, Young-Bin;Kim, Shin-Ho;Ha, Rin;Lee, Hyun-Ju;Lee, Jung-Chul;Bae, Jong-Seong;Kim, Yang-Do
    • Korean Journal of Materials Research
    • /
    • v.20 no.11
    • /
    • pp.586-591
    • /
    • 2010
  • Solar cells have been more intensely studied as part of the effort to find alternatives to fossil fuels as power sources. The progression of the first two generations of solar cells has seen a sacrifice of higher efficiency for more economic use of materials. The use of a single junction makes both these types of cells lose power in two major ways: by the non-absorption of incident light of energy below the band gap; and by the dissipation by heat loss of light energy in excess of the band gap. Therefore, multi junction solar cells have been proposed as a solution to this problem. However, the $1^{st}$ and $2^{nd}$ generation solar cells have efficiency limits because a photon makes just one electron-hole pair. Fabrication of all-silicon tandem cells using an Si quantum dot superlattice structure (QD SLS) is one possible suggestion. In this study, an $SiO_x$ matrix system was investigated and analyzed for potential use as an all-silicon multi-junction solar cell. Si quantum dots with a super lattice structure (Si QD SLS) were prepared by alternating deposition of Si rich oxide (SRO; $SiO_x$ (x = 0.8, 1.12)) and $SiO_2$ layers using RF magnetron co-sputtering and subsequent annealing at temperatures between 800 and $1,100^{\circ}C$ under nitrogen ambient. Annealing temperatures and times affected the formation of Si QDs in the SRO film. Fourier transform infrared spectroscopy (FTIR) spectra and x-ray photoelectron spectroscopy (XPS) revealed that nanocrystalline Si QDs started to precipitate after annealing at $1,100^{\circ}C$ for one hour. Transmission electron microscopy (TEM) images clearly showed SRO/$SiO_2$ SLS and Si QDs formation in each 4, 6, and 8 nm SRO layer after annealing at $1,100^{\circ}C$ for two hours. The systematic investigation of precipitation behavior of Si QDs in $SiO_2$ matrices is presented.