• 제목/요약/키워드: Firefighting protective clothing

검색결과 10건 처리시간 0.025초

한국 소방용 방화복에 대한 만족도 조사 (A Survey of Korean Firefighters Regarding their Satisfaction with Protective Clothing)

  • 한설아;남윤자;최영림
    • 복식
    • /
    • 제58권9호
    • /
    • pp.166-175
    • /
    • 2008
  • For the structural firefighting protective clothing, it can show a synergy effect when it satisfies smart fabric to block off a harmful environmental element and ergonomics design that apply range of motion of human body and appropriate size system. There are various standards about the structural firefighting protective clothing, but it's difficult to find a rule about movement suitability because the performance of the material holds a lot of the rules. Therefore, the purpose of this study is to propose a scheme to evaluate the current structural firefighting protective clothing and to improve movement suitability by research on the actual condition. For this, the survey about wearer acceptability scale on design and size and about improvement requirements was executed gathering firefighters' opinion. Questionnaire was composed with 23 items about satisfaction on current structural firefighting protective clothing, body suitability, movement suitability, improvement requirement and subjective information. As a results, Korean firefighters demand ergonomics design of structural firefighting protective clothing which to minimize restriction of body movement and to maximize body suitability.

한국 소방용 방화복의 치수체계 개발 (Sizing System Development of Korean Structural Firefighting Protective Clothing)

  • 한설아;남윤자;최영림
    • 한국의류학회지
    • /
    • 제33권5호
    • /
    • pp.827-839
    • /
    • 2009
  • Sizing system of Korean structural firefighting protective clothing that is national approved should be met for specification of structural firefighting protective clothing that is identified by Ministry of Public Administration and Security(MOPAS). However if you look over the specification of sizing system, the standard is based on only 'height' and the others are indicated as the size of completed product. KS K ISO 13688 and EN 340 which is met on ISO 13688 which indicates sizing system about protective clothing has the standards of height, chest and waist circumference. Also NFPA 1971 that has standards of sizing system is based on chest circumference, cervical to wrist length, waist circumference and inseam. That is different from Korean standards. Therefore, fire fighting protective clothing standards which is based on only height should be compensated and not be relied on foreign standards like ISO. It is indispensable for developing our own sizing system of structural fire fighting protective clothing. In this studying, Korean new sizing system of structural fire fighting protective clothing was developed for providing basic information of ergonomic structural fire fighting protective clothing. The analyzed target age was between 20 and 59 years old fire fighter who extinguish the fire. And it was analyzed by 3D measurement among data of the $5^{th}$ Size Korea. On conclusion, in case of structural fire fighting protective clothing coat, physical dimension was to be chest circumference, cervical to wrist length. Three dimensions as 5cm space of circumference and four dimensions as 2.5cm space of cervical to wrist length were derived, which means that totally 12 dimensions were defined. Dimension standards of pants was based on the analysis of waist circumference and crotch height. Six dimensions as 5cm space of waist circumference and three dimensions as 5cm space of crotch height were derived, which means that totally 14 dimensions were defined.

3차원 인체형상과 3차원 동작분석에 의한 방화복 소매패턴 개발 (Development of Sleeve Patterns of Structural Firefighting Protective Clothing using by 3D Body Shape and 3D Motion Analysis)

  • 한설아;남윤자;윤혜준;이상희;김현주
    • 한국의류산업학회지
    • /
    • 제14권1호
    • /
    • pp.109-121
    • /
    • 2012
  • This study aims at developing ergonomics patterns for the sleeve of structural firefighting protective clothing through 3D motion analysis in order to ensure efficiency and safety of firefighters who are exposed to harmful environment at work. A new research pattern was developed by applying the total results of 3D motion analysis, changes of body surface length measurements, and 2D data on 3D body shape analysis on the size 3 patterns of the existing coat sleeve. For the sleeves, we used the body surface length of the range of shoulder's flexion and the joint angle of the range of wrist's ulnar deviation. And for the production of structural firefighting protective clothing using the research pattern, we recruited a recognized producer of structural firefighting protective clothing designated by KFI. Unlike everyday clothes, structural firefighting protective clothing should be able to fully protect the wearers from the harmful environment that threatens their lives and should not cause any restrictions on their movement. Therefore, the focus of research and development of such protective clothing should be placed on consistent development of new technologies and production methods that will provide protection and comfort for the wearer rather than production cost reduction or operational efficiency. This study is meaningful as it applied 3D motion analysis instead of the existing methods to develop the patterns. In particular, since 3D motion analysis enables the measurement of the range of motion, there should be continuous research on the development of ergonomics patterns that consider workers' range of motion.

고온조건하에서 소방용 보호복 착용시 주기적 작업과 작업강도에 따른 신체영향 (Effects of Repetitive Work and Workload for body While Wearing Firefighting Protective Clothing in hot conditions)

  • 방창훈
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.35-41
    • /
    • 2018
  • 본 연구는 고온조건하에서 소방용 보호복 착용시 주기적 작업과 작업강도가 신체에 미치는 영향을 연구하여 소방공무원의 건강과 안전을 위한 기초자료 구축을 목적으로 한다. 소방전공 대학생(9명)을 대상으로 소방용 보호장구를 착장한 경우, 실험온도 WBGT $30^{\circ}C$에서 작업강도(3, 9 METs)와 주기적 작업(실험 15분, 휴식 15분, 실험 15분) 따른 비교실험을 수행하였다. 실험결과, 작업강도가 3 METs에서 9 METs로 증가함에 따라 실험기간동안 평균피부온도차(33.3%), 고막온도차(242.9%), 심박수(36.2%), 호흡수(53.9%), 운동자각도(81.6%), 온냉감(20.8%), 체중감소(60.0%), 혈당(-4.4%), 젖산(41.7%)가 통계적으로 유의하게 높게 나타났다. 이상의 결과 고온조건하에서 소방용 보호복 착용시 주기적 작업과 작업강도가 신체에 미치는 영향이 매우 크게 나타나는 것으로 판단된다.

국내외 보급형 소방용 보호장갑의 동작성 평가 -착탈 시험, 기민성 시험, 회전력 시험을 중심으로- (Mobility Evaluation of Popular Firefighting Protective Gloves in Domestic and Foreign Countries -Don-Doff Test, Dexterity Test, and Torque Test-)

  • 김다미;이인성;이주영
    • 한국의류학회지
    • /
    • 제40권5호
    • /
    • pp.921-935
    • /
    • 2016
  • This research analyzed the manual performance of firefighting protective gloves on global markets in order to suggest an evaluation method for firefighting protective gloves wearing comfort. We collected 13 types of firefighting gloves from domestic and international markets (7 types from Korea, 3 types form Europe, 2 types from the U.S and 1 type from Japan). We set the Don-Doff test as a basal requirement for moving toward to further manual performance tests that consist of: ASTM dexterity test, Minnesota dexterity test, Bennett hand tool test and ASTM torque test. All gloves were evaluated in dry and wet conditions, we included eight current male firefighters ($43.4{\pm}7.0yr$ in age, $173.1{\pm}4.4cm$ in height, $79.9{\pm}9.2kg$ in body mass) for the tests. Four gloves (1 Korea, 1 U.S, 1 Germany, and 1 Japan) out of thirteen firefighting gloves passed the Don-Doff test and had great subject preferences. There was no significant difference between dry and wet conditions on the ASTM dexterity test, Minnesota dexterity test, Bennett hand tool test and ASTM torque test. However, Japanese gloves had the greatest score and showed 3-4 times faster completion time on the ASTM dexterity test (p<.05), 1.2-1.5 times faster on the Minnesota dexterity test (p<.05), as fast as the bare hand on Bennett hand tool test (p<.05), and greater performance on the ASTM torque test compared to bare hand. In conclusion, Don-Doff test in wet conditions should be the first step for a mobility evaluation of domestic firefighting protective gloves; subsequently, a comprehensive test assorting ASTM, Minnesota, and Bennett test should be developed as a second step. The current ASTM torque test can be adopted as a third step. This three-step-method for evaluating firefighting protective glove mobility can be expected to expand into surveys of other safety gloves in Korea.

구형과 신형 소방 보호장갑의 착탈 시험 및 동작 기민성 평가를 통한 통합형 착용 시험법 (Integrated Test Method by the Evaluation of Don-doff and Mobility of Old and Newly-developed Firefighting Protective Gloves)

  • 배규태;김도형;신혜영;이주영
    • 한국의류학회지
    • /
    • 제41권5호
    • /
    • pp.950-965
    • /
    • 2017
  • This present study proposed a newly developed test method to evaluate the dexterity and mobility of a firefighter's protective gloves. The first step evaluated the mobility and dexterity of the current type of fire protective gloves and three new types of protective gloves using Don-doff test, ASTM dexterity, Minnesota dexterity, Bennett hand tool test, and ASTM torque test. Three firefighters ($47.3{\pm}5.0yr$ in age, $178.6{\pm}2.9cm$ in height) participated in a series of experiments. The second step was to design and suggest an integrated test method based on the results of the first experiment. As a result of the first experiment, we concluded that 1) the mobility and dexterity tests for firefighting gloves should include both wet and dry tests, 2) The three kinds of dexterity tests could be integrated into one test, and 3) The don-doff test and the torque test should be independent from the newly developed integrated test. In summary, we suggested a simplified test method that combined ASTM dexterity, Minnesota dexterity, and Bennett hand tool test. The integrated system can reduce total time spent on dexterity tests and improve the validity of the test in terms of firefighters' manual work.

소방용 화학보호복 착용 현장대원의 일상 훈련용 프로토콜 설계 및 활동성 분석 (Design of Daily Training Protocol for Field Crews Wearing Chemical Protective Clothing for Firefighting and Analysis of Activity)

  • 김시국;임우섭;홍성철
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.110-121
    • /
    • 2018
  • 본 논문은 소방용 화학보호복 착용 현장대원의 일상 훈련용 프로토콜 설계 및 활동성 분석에 관한 연구이다. 화학사고 및 화학테러 현장에 최초 투입되는 소방대원들의 대처능력 향상 및 안전성 확보를 위해 총 10단계의 일상 훈련용 프로토콜을 설계하였다. 설계된 프로토콜은 크게 소방용 화학보호복 일상 적응을 위한 광범위 활동 프로토콜(1, 2, 6, 7, 9단계)과 손을 활용한 정밀작업 프로토콜(3, 4, 5단계) 그리고 강한 신체적 부담을 요구하는 프로토콜(8, 10단계)로 구성하였다. 프로토콜에 따른 활동성 측정결과 소방용 화학보호복 착용 시가 미착용 시보다 평균최대심박수는 1단계 20.32%, 2단계 18.69%, 3단계 25.23%, 4단계 34.77%, 5단계 27.44%, 6단계 30.24%, 7단계 25.33%, 8단계 22.25%, 9단계 22.80%, 10단계 20.85% 증가되는 것으로 나타났다. 평균최대호흡수는 1단계 및 2단계를 제외하고 3단계 1.92%, 4단계 4.11%, 5단계 1.24%, 6단계 3.95%, 7단계 0.93%, 8단계 10.23%, 9단계 3.36%, 10단계 15.10% 증가되는 것으로 나타났다.

소방 방화복 교차오염 저감 및 관리체계 개선을 위한 델파이 연구 (Delphi Study on the Reduction of Cross-contamination and Improvement of Management System on Firefighting Protection Suit)

  • 김수진;함승헌
    • 한국산업보건학회지
    • /
    • 제32권2호
    • /
    • pp.182-194
    • /
    • 2022
  • Objectives: This study evaluates and recommends the priority of policy implementation to improve the fire protection clothing management system used by firefighters and the reduction of cross-contamination from contaminated clothing at the scene of a fire. Methods: It consisted of 7 experts and conducted three interviews and two modified Delphi surveys. Through the results of previous research and interviews with experts, a plan to reduce cross-contamination of fire suits and improve the management system was first derived. An improvement plan was presented in the four areas including resources, management, fire protection related work, and laws and regulations, and the priority of policy implementation was derived by analyzing the importance and practicality of the policy at the same time. Results: As a result of the analysis, the first priority was education on the health effects of pollutants at the disaster scene for firefighters, and the second priority was the addition of SOP for the primary decontamination of on-scene personal protective equipment in preparation for the health effects of the disaster scene, and education for fire suppression and rescue workers. The next step was to improve the management system of personal protective equipment such as fire suits and develop a training course for systematic operation. Conclusions: This findings could be used in the implementation of mid- to long-term firefighting policies for the systematic operation and establishment of a systematic management system for personal protective equipment such as fire protective suits.

중앙119구조본부 소방대원용 화학 보호복과 방열복의 동작적합성 평가 및 디자인 개선 (Enhancing Design and Evaluating Mobility of Firefighting Chemical and Flame Protective Clothing for the National 119 Rescue Headquarters)

  • ;김도희;이주영
    • 한국의류산업학회지
    • /
    • 제25권4호
    • /
    • pp.520-533
    • /
    • 2023
  • The present study developed a test protocol for evaluating the mobility of firefighting chemical and flame personal protective equipment (PPE) for the National 119 Rescue Headquarters in Korea and suggested ergonomic design factors to improve their mobility and performance. Six types of PPE were employed, including three types for flame protective PPE (5 ~ 6 kg excluding the self-contained breathing apparatus), and three types for chemical and flame protective PPE (8 ~ 11 kg). These PPEs are used by the 119 Rescue firefighters. Three male firefighters (34.3 ± 1.2 y in age, 175 ± 8 cm in height, 81 ± 13 kg in body weight) participated in the mobility test and interview. A mobility test protocol consisting of 16 components (nine postures and seven motions including a dexterity test) along with a visibility test were developed based on pre-interviews and literature reviews. The findings indicated that the clothing microclimate humidity on the neck and chest exceeded 85%RH on average for all the six PPE conditions, with the chest area reaching as high as 98%RH. This high humidity caused fogging inside the visor and impaired visibility. The requirements for improving the PPE design in terms of mobility varied depending on whether it was the separated types or all-in-one types, particularly regarding the hood and gloves design. The findings of this study can be applied to improve the design of Level A_PPE for firefighters. The mobility test protocol and visibility test developed in this study can also be applied to other types of Level A impermeable PPE.

한국 소방방수피복의 착용만족도 및 개선방안에 관한 조사연구 (A Study on the Wearing Comfort of Firefighter's Protective Clothing)

  • 정정숙;이연순
    • 대한가정학회지
    • /
    • 제37권12호
    • /
    • pp.59-67
    • /
    • 1999
  • This study analyzed firefighter's actual wearing condition of turnout gear The results are as fellows: 1. When a firefighter is employed, Korea applies only the minimum of firefighters stature and weight but America applies both the minimum and the maximum. The choice of size is highly related with stature more than chest circumference. 2. The satisfaction degree of thermal barrier is very low, 3%. They used rubber gloves rather than heatproof gloves. This is more serious in small country like 'up', 'myun' than in cities. For laundering, they used sprinkling method with firefighting hose. Firefigthers hoped that their clothes could be classified tv the seasons and fire places. 3. frefighter had high unsatisfaction with the movement of hands and leges in the aspect of movement adjustability, air permeability, weight, body temperature regulation, and breathing in the hygenic aspect, fire resistance, thermal resistance property, water proof, chemical reactivity and electrical conductivity. Thev were also unsatisfied with water proof boots and gloves. They were generally satisfied with helmets but firefighters over 90kg of weight were rather unsatisfied. 4. The satisfaction degree for physical fitness was very low and the items with which they were not satisfied depend on physical features. 5. To develop turnout gear, they wanted changes in design, material and size. Reflection tape need to be replaced with high quality products and they wanted the use of velcro and zipper in fastening system.

  • PDF