A systematic experimental study is carried out for the fire fighting monitor nozzle of 65A diameter to design and manufacture a new nozzle with better water spray performance than available domestic nozzles. The nozzle inlet pressure, flow rate and reach for the discharged water from the nozzle are measured by utilizing the experimental facility consisting of two pumps and piping system with a flow meter and pressure gauges. It was found that the baffle position and baffle head chamfering were the most sensitive design factors to be remarkably changed in the flow rate of the discharged water. Also, It was confirmed that the baffle position and the water exit area had the significant effect on the change in reach distance. The results obtained from this study are expected to be used effectively to design new nozzles with excellent spray performances and also to validate numerical analysis results for evaluating the water spray performance of fire fighting monitor nozzles.
이 연구는 공설소화전에 대한 지상식 및 지하식 소화전의 소방용수 사용 준비시간을 분석하였다. 1단계인 장비 준비시간은 지상식은 20.50초, 지하식은 24.67로 나타났다. 이와 같이 준비시간이 다소 차이가 난 것은 지하식 소화전은 맨홀 뚜껑을 개방하는 빠루와 지하식 소화전 본체 관구에 연결하기 위하여 스탠드 파이프가 추가로 필요했기 때문이다. 2단계인 물탱크차의 보수구에 숫커플링의 수관결합은 지상식은 48.50초, 지하식은 49.00초로 비슷하게 나타났다. 이것은 물탱크차 보수구에 소방호스를 연결하는 동작이 같기 때문이다. 3단계인 본체 관구에 수관 결합은 지상식은 43초, 지하식은 174.33초로 나타났는데 이와 같이 수관을 소화전 관구에 연결하는 시간이 큰 차이가 난 것은 지하식 소화전은 맨홀 뚜껑을 개방한 후 소화전 본체 관구에 스텐드 파이프를 연결한 후에, 스텐드 파이프 관구에 수관을 결합하는 추가 과정이 필요하여 소요시간을 크게 올린 것으로 판단된다. 4단계인 제수 밸브와 스핀들 개방은 지상식은 66.50초, 지하식은 78.83초 소요되었다. 이 같은 차이가 난 것은 지상식 소화전의 스핀들은 본체 관구위에 위치하여 쉽게 개방이 가능하지만, 지하식은 맨홀 아래 관구 옆에 위치하여 개방 장비인 복스퍼너를 연결하는 추가시간이 필요하여 나타난 결과로 판단된다.
소화활동설비 중 연결송수관설비는 출동한 소방대가 소화용수를 공급하는데 화재현장 활동에서 그 어떤 설비보다 중요하다. 본 연구에서는 연결송수관설비 화재안전기준(NFSC 502)을 바탕으로 연결송수관설비가 설치된 아파트에 대한 연결송수구 설치 위치를 조사하였다. 소방대원이 아파트에 설치된 연결송수관설비 송수구를 알고 있는 경우와 모르고 있는 경우 그리고 주간과 야간을 나누어 연결송수관설비 송수구 발견 시간을 측정하여 보았다. 실험결과를 바탕으로 소방대가 출동하여 활용하는 본격 소화설비인 연결송수관설비의 활용 극대화를 위하여 연결송수관 설치 위치에 대한 명확화 및 위치안내도 표지판 설치 등 연결송수관설비 화재안전기준(NFSC 502)에 대한 개선안을 제안하고자 한다.
본 연구에서는 화재현장에서 사용하는 소방호스에 대하여 사용압력과 방수량 변화에 따른 마찰손실을 실측하였다. 소방호스의 종류, 수량, 사용압력 등 소방호스의 사용 실태를 분석하여 그 결과를 토대로 실측한 결과 화재현장에서 소방공무원이 사용하는 조건에서 소방호스의 마찰손실은 무려 56.8%까지 측정되었다. 옥내 외 소화전설비에서 펌프양정 계산시 사용하는 소방호스의 등가 길이와도 많은 차이가 난다. 관련규정조차 마찰손실에 대한 제한 규정이 없고, 소방호스를 생산하는 업체에서도 마찰손실을 측정한 자료가 없으며, 화재현장에서는 마찰손실을 고려하지 않고 소방호스를 전개함으로써 호스의 사용량이 많아지고 소방펌프차에서 고압으로 방수하게 되는 원인이 되므로 본 연구를 통하여 소방호스 마찰손실에 대한 등가길이 기준을 정립하고 화재현장에서 소방호스의 마찰손실을 고려한 전개 방법을 제안하고자 한다.
본 연구는 교육시설물의 부위별 공사비 및 유지관리비 분석을 목적으로 수행되었다. 이를 위해 BTL 사업으로 발주된 서울지역에 위치한 초등학교 4곳을 사례 대상으로 선정하였다. 이렇게 선정된 사례 대상을 바탕으로 부위별 체계 정립을 위한 모델을 제시하였으며, 정립된 부위별 체계에 따라 공사비 및 유지관리비를 분석하였다. 이에 따라 부위별 공사비 분석표와 유지관리비 분석표 그리고 교육시설물의 적정 공사비 및 유지관리비를 제시하였다. 상기와 같은 목적과 방법에 따라 진행된 본 연구의 결론을 요약하면 다음과 같다. 1)사례 대상 학교 4곳의 부위별 공사비 산정에 따른 평균 금액 비율을 살펴보면 다음과 같다. 총 공사비 6,666백만원 대비 구조체 47.15%, 건물외부 8.34%, 건물내부 23.37%, 전기 소화 5.74%, 급수 위생 4.27%, 난방 급탕 5.25%, 옥외시설 1.36%, 토목 4.51%를 차지하는 것으로 분석되었다. 2)사례 대상 학교 4곳의 부위별 유지관리비 분석에 따른 평균 금액 비율을 살펴보면 다음과 같다. 총 유지관리비 4,309백만원 대비 건물외부 11.02%, 건물내부 41.81%, 전기 소화 14.81%, 급수 위생 11.22%, 난방 급탕 12.76%, 옥외시설 5.75%, 토목 2.63%를 차지하는 것으로 분석되었다.
지하공동구는 도시 및 공동주택 단지에 반드시 필요한 전력, 통신, 가스, 송유관, 급 배수, 에너지시설 등을 효과적으로 수용하고 도시기반시설의 확장에 따라 파생되는 여러 가지의 문제점을 해결하기 위한 방안으로 시설물을 한곳으로 모아 유지 및 관리하는 시설이다. 지하공동구가 훼손될 경우 국가안보는 물론 사회전반에 미치는 파장이 지대하므로 화재예방 활동 및 진압대 책상 취약점 등을 분석하여 우리 실정에 맞는 방재 대책을 도출하여 공동구의 설계, 제도적인 문제, 방화시설의 문제, 화재확산현상 등을 분석하여 종합적인 화재위험을 분석하여 화재예방활동과 진압대책을 수립하여야 한다. 지하공동구는 밀폐 폐쇄된 공간이므로 산소공급 부족으로 인한 불완전 연소 등으로 농연, 일산화탄소 등 유독성연소생성물의 발생과 열기의 충만 및 시야장해로 진입이 곤란 하는 문제점이 있다. 이러한 현상은 지상화재보다는 지하 화재의 특수성에 비추어 볼 때 화재예방활동은 물론이고 소방전술에서 취약하므로 화재의 효율적인 소방전술이 되기 위해서는 화재의 특이성을 감안하여 유관기관에서는 현장대응 지휘체제를 확립하고, 대응기관에서는 평상시 공동구에 대한 구조파악과 필요한 각종 정보를 수집 기록하고 24시간 관리공조체제 유지 및 대응기관에서 가상종합훈련을 강화하여야하며 근본적으로 공동구내에 설치되어 있는 케이블의 난연화 불연화 및 연소 확대 방지를 위한 대책 등이 필요하다.
Hyun-Wook Kang;Seung-Wook Lee;Sung- Ryul Bae;Byoung-Jun Min;Moon-Sun Park;Yong-Su Kim
국제학술발표논문집
/
The 3th International Conference on Construction Engineering and Project Management
/
pp.1254-1259
/
2009
The purpose of this study is to analyze elemental maintenance costs for educational buildings. The adapted research method selected three school buildings in Seoul as BTL projects. On the basis of the selected case, the study suggested a model to establish a system for each parts and to estimate analyzed maintenance costs through that system. According to the analysis, the study proposed a partial maintenance costs standard and analyzed proper maintenance costs. The results of this study are as follows 1) The system is divided into 8 large-groups and 24 small-groups for the analysis elemental maintenance costs. 2) The average rations followed by analysis of partial maintenance costs of the three school buildings are as followings, the total maintenance costs are analyzed 3,992 million won and each part of average rations is exterior of building 10.9%, interior of building 41.58%, electricity & fire fighting facility 14.22%, water supply & healthy facility 11.39%, heating & water supply facility 12.93%, landscape 6.3%, civil engineering works 2.69%.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.