• Title/Summary/Keyword: Fire- and explosion safety

Search Result 404, Processing Time 0.037 seconds

Study on Fire.Explosion Accidents Prediction Model Development of LPG Vaporizer (LPG 기화기의 화재.폭발사고 예측모델개발에 관한 연구)

  • Ko, Jae-Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.28-36
    • /
    • 2010
  • We have garnered 3,593 data of gas accidents reported for 12 years from 1995, and then analyzed the LPG vaporizer accidents according to their types and causes based on the classified database. According to the results the gas rupture has been the most common accident followed by the release, explosion and then fire accidents, the most frequent accident-occurring sub-cause is LPG check floater faults. In addition, we have applied the Poisson Probability Functions to predict the most-likely probabilities of fire, explosion, release and rupture with the LPG vaporizer in the upcoming 5 years. In compliance with Poisson Probability Functions results, in the item which occurs below 3 "LPG-Vaporizer-Fire", in the item which occurs below 5 "LPG-Vaporizer-Products Faults-Check Floater" and the item which occurs below 10 appeared with "LPG-Vaporizer-Products Faults". From this research we have assured the successive database updating will highly improve the anticipating probability accuracy and thus it will play a key role as a significant safety- securing guideline against the gas disasters.

Development of Disaster Safety Program for Small-sized Workplaces and Its Introduction to Occupational Safety&Health Act: Focusing on Fire, Explosion and Chemical Spill (소규모 사업장 재난안전 프로그램 개발 및 산업안전보건법에의 도입방안: 화재, 폭발, 약품 누출을 중심으로)

  • Ko, Seung-cheol;Eum, Tae-Soo;Song, Chang-Geun
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.7
    • /
    • pp.84-90
    • /
    • 2021
  • 98.8% of accidents occurring in domestic companies are concentrated in small-sized workplaces with fewer than 50 employees. Therefore, this study developed a disaster safety program that can be implemented by small and medium-sized enterprises by comparing and analyzing the safety management system actively used with the laws and regulations related to industrial safety and facilities. The disaster and safety program included the scope of application, organizational structure, risk assessment, emergency response system, education and training, safety equipment provision and program evaluation, and detailed preparation methods and procedures for each item. In addition, items to be aware of when operating a disaster safety program and operational strategies were presented. After that, it was proposed to introduce the research results into the Occupational Safety and Health Act.

The Evaluation of Fire Reliability for the High Pressure Hydrogen Storage System of Fuel Cell Vehicle (I) (연료전지자동차의 고압수소저장시스템 국부화재 신뢰성 평가 (I))

  • Kim, Sang-Hyun;Choi, Young-Min;Hang, Ki-Ho;Shim, Ji-Hyun;Hang, In-Cheol;Lim, Tae-Won
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.4
    • /
    • pp.520-526
    • /
    • 2011
  • In recent years, it is very important that hydrogen storage system is safe for user in any circumstances in case of crash and fire. Because the hydrogen vehicle usually carry high pressurized cylinders, it is necessary to do safety design for fire. The Global Technical Regulation (GTR) has been enacted for localized and engulfing fire test. High pressure hydrogen storage system of fuel cell electrical vehicles are equipped with Thermal Pressure Relief Device (TPRD) installed in pressured tank cylinder to prevent the explosion of the tank during a fire. TPRDs are safety devices that perceive a fire and release gas in the pressure tank cylinder before it is exploded. In this paper, we observed the localized and engulfing behavior of tank safety, regarding the difference of size and types of the tanks in accordance with GTR.

A Study on Real Condition Estimation for Fire Protection Safety Management System Builds (소방안전경영시스템 구축을 위한 실태평가에 관한 연구)

  • Kang, Gil-Soo;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.18-24
    • /
    • 2013
  • Goverment and enterprises have been devoting a lot of dffort in order to prevent the loss of human and property due to a large, diversified fire, explosion, global warming and disasters caused by natural phenomena. But Enterprises came forward and running in the economy priority policy for profit-seeking until now in order to meet the macro purpose of quality improvement of national life and welfare promotion in company with National growth, as a result of lax risk management have had to endure the loss of precious lives and property. According to the '2007 Survey of public safety for the activation of the safety culture' of National Emergency Management Agency [NEMA], a insensitivity of safety in our society was surveyed 'a serious level'. In this study, surveyed need of 'step-by-step fire protection safety management system builds' in order to prevent fire safety accident and improvement of safety awareness level through a systematic management and real condition estimation of not only large business that can control risk management, but also small business that has a big risk to occur accident easily according to small budget and organization.

A Study on the Explosionproof devices Installation in the Manufacturing Process (제조업체 방폭설비 적용에 관한 연구)

  • Song, Yong-Sig;Lee, Jun-Suk;Jeong, Hyun-Gyu;Cho, Won-Cheol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.565-570
    • /
    • 2007
  • The explosionproof apparatus is a devices that is enclosed in a case capable of withstanding an explosion of a specified gas or vapor that may occur within it and of preventing the ignition of a specified gas or vapor surrounding the enclosure by sparks, flashes, or explosion of the gas or vapor within, and that operates at such an external temperature that a surrounding flammable atmosphere will not be ignited thereby This kind of exeplosionfproof devices should be installed suitable for the characteristics of the space or process condition that should be protected to prevent explosion or fire. But, due to the lack of information and techniques on the explosionproof technology, some dangerous area is not properly protected from an explosion or it cost too much to implement the explosionproof devices. In this report, the basic guidelines and several case studies of explosionproof devices installation will be introduced to be of help to field safety engineer.

  • PDF

A Study on the Thermal Characteristics and Fire Hazard of Iron Powder Accumulated on Circuit Break (차단기 누적 철분진의 열적특성과 발화위험성 연구)

  • Kim, Doo-Hyun;Kang, Yang-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.4
    • /
    • pp.20-25
    • /
    • 2012
  • The purpose of this study is to analyze the thermal characteristics and to study fire hazard of electric leakage by iron power accumulated on circuit breaker in an iron processing factory. The thermal characteristics were analyzed while current was applied to the powder for ten minutes. Results showed that temperature of iron powder at 100 mA is $160^{\circ}C$ and at 175mA is $240^{\circ}C$. The sparks have occurred as iron powder drops between two(hot line and neutral line) wires and then iron powder explosion occurred while dropping continuously the iron powder on two lines. Those who work in the iron processing industry need to periodically remove and maintain the iron powder. The thermal characteristics in this paper can be used for electrical fire investigation and for basic data of thermal characteristic of leakage current through iron powder at iron processing factories.

A Study on the Development of Installation and Management of Safety Shower (Safety shower 설치 및 관리기준 개선에 관한 연구)

  • Lee, Dong Hyeok;Yoo, Byung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.1-7
    • /
    • 2018
  • Currently chemical plant risk have been issued by occurring frequent accidents. Accidents can be generally composed of fire, explosion, release in chemical plant. In case of fire and explosion, accident victims are occurred immediately after accident but release accident, late emergency response cause damage to worker. Especially, there are many victims by late emergency response against chemical exposure to skin. In case of chemical exposure to skin, irreversible damage like death, blindness, burn can be prevented by washing immediately. Safety shower can provide the cleaning for chemical exposure to eye, skin. Most of chemical plants are built in 1980s so equipment become superannuated. In this reason, safety shower also cannot operate normally in emergency situation. Therefor safety shower should be managed by installation and management guideline. This study perform the establishment guideline for safety shower installation and inspection to increase the reliability.

A Study on the Efficiency of Dust Explosion According to Particle Size and Concentration of Dust Using the Cone Calorimeter (산소소모열량계를 이용한 분진의 입경과 농도에 따른 분진폭발의 효율에 대한 연구)

  • Kim, Yun-Seok;Moon, Sung-Woong;Woo, In-Sung;Rie, Dong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.116-119
    • /
    • 2011
  • 분진의 입경과 농도의 변화에 의한 분진의 폭발압력과 압력상승속도 및 그에 따른 분진폭발지수(Kst), 최소점화에너지(MIE) 및 폭발범위 등 분진폭발에 관한 많은 연구가 진행되고 있다. 폭발 메커니즘의 이해와 이를 통한 예방을 위해서는 분진폭발의 폭발효율과 열방출률(Heat Release Rate)에 관한 연구도 필요하다. 본 연구에서는 산소소모열량계를 이용하여 분진폭발 전후의 열방출률의 차이를 통하여 폭발효율과 폭발의 에너지를 정량화하고, 이를 통해 분진폭발 위험도의 정량적 평가기준을 제시하였다.

  • PDF

Study on Explosion Characteristics and Thermal Stability of Activated Carbon (활성탄의 폭발특성과 열안정성에 관한 연구)

  • Yi-Rac Choi;Dong-Hyun Seo;Ou-Sup Han;Hyo-Geun Cha
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.134-140
    • /
    • 2023
  • Activated carbon is a carbonaceous material mainly used as a gaseous or liquid adsorbent. As fire-related accidents occur consistently due to the accumulation of heat of adsorption and oxidation of volatile organic compounds, the explosive characteristics and thermal stability of powdered and granular activated carbon made from coal and coconut shells were evaluated. As a result of the particle size analysis, the powdered activated carbon was in the particle size range (0.4~3) ㎛, and thermal properties such as exothermic onset temperature and decomposition behavior were analyzed using a differential scanning calorimetry and a thermogravimetric analysis. As a result of the evaluation of the explosion hazards for dust, both coal-based and coconut-based powdered activated carbon are classified as St1 class with weak explosion, but this is a relative and does not mean that the explosion hazards is absolutely low. Therefore, it is necessary to establish countermeasures for reducing the damage.