• Title/Summary/Keyword: Fire water duration

Search Result 10, Processing Time 0.026 seconds

A Comparison Study on Fire Water Supply Duration and Capacity of Water Based Fire Suppression System of the United States, Japan, China and Korea (우리나라, 중국, 일본, 미국 수계소화설비 소화수 공급시간 및 소화수원에 대한 비교 연구)

  • Min, Se-Hong;Nam, Yu-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.13-20
    • /
    • 2013
  • Buildings in Korea have been getting higher recently and been being changed environmentally since the Korean fire standard was released in 1968. It should be established to make a appropriate correspondence of fire fighting against the those environmental changes. Most of all, fire water capacity which is basis of fire fighting service is a very significant factor. In this paper, the Korean fire water capacity and fire water duration were compared with China, Japan and the United states. Furthermore, fire water capacity, fire water duration, flow rate were compared by hazard classification, occupant use, number of floor and area with water based fire suppression system. This study has been surveyed to show what are difference, similarity, advantage and disadvantage on fire water capacity in the Korean standard comparing with neighboring countries like China, Japan as well as the United states. This study could be found what level the Korean fire water capacity is. So it suggests about more developed standard on fire water capacity with the result of analysis and comparison.

Strength recovery of fire-damaged concrete after post-fire-curing (화재 후 재양생 조건에 따른 콘크리트의 강도복원특성)

  • Lee, Joong-Won;Choi, Kwang-Ho;Hong, Kap-Pyo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.170-173
    • /
    • 2006
  • The purpose of this study is to investigate the effect of post-fire-curing on the strength recovery of fire-damaged concrete The 170 specimens have been tested with variables of concrete strengths(20, 30, 40, 50, 60Mpa) exposed to elevated temperatures till $600^{\circ}C$ and $800^{\circ}C$. After natural cooling, the specimens were subjected to post-fire-curing in water and in a controlled chamber for a total duration of 56days. Unstressed compressive strength was conducted to examine the change in the concrete. The test results indicated that the post-fire-curing results in substantial strength recovery and its extent depend on the method and duration of recuring.

  • PDF

A Study on the Development of Advanced Model to Predict the Sodium Pool Fire

  • Lee, Yong-Bum;Park, Seok-Ki
    • Nuclear Engineering and Technology
    • /
    • v.29 no.3
    • /
    • pp.240-250
    • /
    • 1997
  • Liquid sodium is widely used as a coolant of LMR(Liquid Metal Reactor) because of its physical and nuclear properties. However, the liquid sodium is very chemically reactive with oxygen and water so that the study on the sodium fire plays an important role in the LMR safety analysis. In this study, a sodium fire model is suggested to analyze the sodium pool fire where both the flame and the reaction products are considered. And also, sodium pool fire analysis computer code, SOPA, is developed. The sensitivity study on the experimental parameters such as the thermal radiation from flame to atmospheric gas, the vessel cooling and the duration of sodium spill was performed. The results showed good agreements with experimental data in the literature.

  • PDF

Experimental study of sodium fire and its characteristics under the coupling action of columnar liquid sodium flow and concrete

  • Huo, Yan;Zou, Gao-Wan;Dong, Hui;Lv, Jian-Fu;He, Jian
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2866-2877
    • /
    • 2021
  • The complex coupling relationship between liquid sodium and concrete materials affects both the sodium fire characteristics and concrete properties through heat and chemical erosion. In this study, experiments on direct and indirect (separated by a steel plate) contact of the columnar sodium fire with the concrete surface were performed. It was found that the combustion efficiency of liquid sodium in direct contact with concrete was significantly enhanced and accompanied by intermittent explosions and splashing of small concrete fragments. The sodium fire on the surface of the concrete considerably increased the internal temperature, pore size, and distribution density of the concrete. In addition, the depth of influence on the loosening of the concrete structure was also greatly extended. The contact of liquid sodium with the concrete substantially affected its permeability resistance. The water absorption of the concrete surface was increased by more than 70% when liquid sodium directly impacted the bare concrete surface. However, the change in water absorption in the centre of the concrete was primarily affected by the duration of the external heat.

An Experimental Study on Development of a Window Sprinkler for Fire Spread Prevention along Building External Walls (건물 외벽 화재확산 방지용 윈도우 헤드의 개발을 위한 실험적 연구)

  • Kwark, Jihyun;Kim, Dong-Jun
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.8-13
    • /
    • 2013
  • In case of fire in a high-rise building fire can be easily spread along the building external walls dramatically if the flame comes out through broken windows. There are a few effective methods to prevent the fire spread at the moment. One is using a fire resistance window, and the other is using a window sprinkler that discharges water to resist flame in case of fire. In this study a window sprinkler which is installed on top of windows and prevents fire by discharging water when its heat-responsive element opens was tested using a large scale furnace in accordance with the standard temperature-time graph. Test result showed that one window sprinkler was able to protect a 2,400 mm wide window from fire for 2 hours and the window backside's temperature locally increased up to $126^{\circ}C$ but kept stable around $100^{\circ}C$ for the test duration.

Characteristics of HFIX Insulated Wire Sheaths Contaminated by Pollutants (오염물질에 따른 HFIX 절연전선 피복의 특성 변화에 관한 연구)

  • Choi, Su-Gil;Nam, Yeong-Jae;Jin, Se-Young;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.8-17
    • /
    • 2020
  • In this study, the characteristics of HFIX insulated wire sheaths contaminated by pollutants were examined. KS C IEC 60811-1-3 standard was followed in performing the water-resistance wire tests. Pollutants were selected, and the specimens were exposed to the pollutants for a maximum duration of four weeks. The maximum tensile load and the elongation rate were measured each week. As the period of pollution exposure increased, the maximum tensile load of the specimens decreased by 6.22% and 6.52% at room temperature and high temperature, respectively, and 19.94% for specimens coated with a rust-proof lubricant. The elongation rate also decreased rapidly, such that the reductions in the properties of the sheath were significant. From the analysis of the surfaces using a scanning microscope, as the contamination period increased, structural changes such as perforation, split, and melting occurred, and the mechanical properties of the specimens decreased. Therefore, it is necessary to develop and follow an inspection cycle and periodically carry out repairs to prevent the deterioration of insulated wires.

Thermal Impact Characteristics by Forest Fire on Porcelain Insulators for Transmission Lines

  • Lee, Won-Kyo;Choi, In-Hyuk;Choi, Jong-Kee;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.143-146
    • /
    • 2008
  • In this study the thermal impact characteristics by forest fire are extensively investigated using temperature controlled ovens. The test conditions for thermal impact damage are simulated according to the characteristics of natural forest fire. The test pieces are suspension porcelain insulators made by KRI in 2005 for transmission lines. In the thermal impact cycle tests with $300\;^{\circ}C$ thermal impact gradient (-70 to $230\;^{\circ}C$), cycling in 10 minute periods, no critical failures occurred in the test samples even with long cycle times. But in tests with thermal impact gradient from room temperature to $200-600\;^{\circ}C$, cycling in 10 to 30 minute periods, there were critical failures of the porcelain insulators according to the thermal impact gradient and quenching method. In the case of thermal impact by forest fire, it was found of that duration time is more important than the cycling time, and the initiation temperature of porcelain insulator failures is about $300\;^{\circ}C$, in the case of water quenching, many cracks and fracture of the porcelain occurred. It was found that the thermal impact failure is closely related to the displacement in the cement by thermal stress as confirmed by simulation. It was estimated that the initiation displacement by the thermal impact of $300\;^{\circ}C$ is about 0.1 %. Above 1% displacement, it is expected that the most porcelain insulators would fail.

A Study on the Analysis of Concrete Vertical form Demolding Timing Considering the Relationship between the Type of Coarse Aggregate and Ultrasonic Pulse Velocity (굵은 골재의 종류와 초음파 속도의 관계성을 고려한 콘크리트 수직 거푸집 해체 시점 분석에 관한 연구)

  • Nam, Young-Jin;Kim, Won-Chang;Choi, Hyeong-Gil;Lee, Tae-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.6
    • /
    • pp.683-692
    • /
    • 2023
  • This research assesses the mechanical properties of concrete, utilizing both normal and lightweight aggregates, through measurements of compressive strength and ultrasonic pulse velocity. The study observed that concrete with normal aggregates exhibited higher compressive strength in its initial stages, whereas concrete with lightweight aggregates showed increased strength over time, likely attributed to the higher water absorption rate of lightweight aggregates. Ultrasonic pulse velocity generally registered higher in normal aggregate concrete, barring a specific duration, presumably due to variations in the internal pore structure of the aggregates. The correlation coefficient(R2) for the strength prediction equation, derived from the relationship between compressive strength and ultrasonic pulse velocity, exceeds 0.95. This high correlation suggests that the predictive equation based on these experimental findings is a reliable method for estimating concrete strength.

A Study on Emission Properties of Green House Gas on Duration Combustion of Constructive Wood Materials (건축용 목재의 연소시 지구온난화 가스의 배출특성에 관한 연구)

  • An, Hyung-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.123-128
    • /
    • 2018
  • MDF was treated on the surface of MDF with fire retardant lacquer, water-soluble flame retardant coat and water-soluble wood cover on the MDF wood, and the pyrolysis characteristics and the atmospheric noxious gas generation characteristics were investigated by using the large capacity thermal analyzer. As a result of investigating pyrolysis and combustion gas generation characteristics after treatment of 0.11 / 11.55 g in terms of mass ratio, it was found that combustion starting time was slightly longer than that of pure MDF in the case of treatment with fire retardant lacquer. The combustion temperature was increased from $340^{\circ}C$ to $450^{\circ}C$. The pyrolysis and combustion gas generation characteristics of the MDF wood treated with the aqueous flame retardant coat showed the changes in combustion starting time and temperature from $260^{\circ}C$ to $542^{\circ}C$ for about 26 minutes at the mass ratio of 0.13 / 11g. Also, when the commercially available waterproof wood cover was treated with 0.13 / 11.55 g of MDF, the sudden weight change tended to increase from $300^{\circ}C$ to $370^{\circ}C$ and showed a second change at approximately $500^{\circ}C$.

Analysis of the potential landslide hazard after wildfire considering compound disaster effect (복합재해 영향을 고려한 산불 후 산사태 잠재적 피해 위험도 분석)

  • Lee, Jong-Ook;Lee, Dong-Kun;Song, Young-Il
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.22 no.1
    • /
    • pp.33-45
    • /
    • 2019
  • Compound disaster is the type that increases the impact affected by two or more hazard events, and attention to compound disaster and multi-hazards risk is growing due to potential damages which are difficult to predict. The objective of this study is to analyze the possible impacts of post-fire landslide scenario quantitatively by using TRIGRS (Transient Rainfall Infiltration and Grid-Based Regional Slope-Stability Analysis), a physics-based landslide model. In the case of wildfire, soil organic material and density are altered, and saturated hydraulic conductivity decrease because of soil exposed to high temperature. We have included the change of soil saturated hydraulic conductivity into the TRIGRS model through literature review. For a case study, we selected the area of $8km^2$ in Pyeongchang County. The landslide modeling process was calibrated before simulate the post-wildfire impact based on landslide inventory data to reduce uncertainty. As a result, the mean of the total factor of safety values in the case of landslide was 2.641 when rainfall duration is 1 hour with rainfall intensity of 100mm per day, while the mean value for the case of post-wildfire landslide was lower to 2.579, showing potential landslide occurrence areas appear more quickly in the compound disaster scenario. This study can be used to prevent potential losses caused by the compound disaster such as post-wildfire debris flow or landslides.